    LDP-124, LDP-126, LDP-144 AND LDP-146 OPERATOR´S MANUAL FOR CLOCK MODELS http://www .omega.com e-mail: info @ omega.com User's Guide ...

  • Omega LDP-126 - page 2

    OMEGAnet  On-Line Service Internet e-mail http://www.omega.com info@omega.com Servicing North America: USA : One Omega drive, Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 Tel : (203) 359-1660 Fax : (203) 359 7700 e-mail : info@omega.com Canada : 976 Bergar Laval (Quebec) H7L 5A1 Tel : (514) 856-6928 Fax : (514) 856-6886 e-mail : info@omeg ...

  • Omega LDP-126 - page 3

    Page : 2 CONTENTS DESCRIPTION SECTION PAGE =========================================================================== IMPORTANT SAFETY CONSIDERATIONS 13 UNPACKING AND INSPECTION 24 MAIN FEATURES 34 MODELS 45 MODEL LDP-1XX-C0, DISPLAY TIME USING THE FORMAT MM : SS 4. 1 5 MODEL LDP-1XX-C1, DISPLAY TIME USING THE FORMAT HH : MM 4. 2 5 MODEL LDP-1XX-C ...

  • Omega LDP-126 - page 4

    Page : 3 INSTALLATION PRECAUTIONS.- The installation and the future use of this unit must be done by suit- able qualified person- nel. The unit has not AC (mains) switch, it will be in operation as soon as power is connected. The installation must incorporate an external main switch. The unit has a protection fuse incorporated on the AC socket, if ...

  • Omega LDP-126 - page 5

    Page : 4 2.- UNP ACKING AND INSPECTION It is advisable to do a detailed reading of this Manual before mounting the instrument. This Operator's Manual contains all the technical specifications : electricals as well as mechanics, both necessary to do a correct installation and also a good use of the instrument. At the same time the user will acq ...

  • Omega LDP-126 - page 6

    Page : 5 The common features for all series are the following: MECHANICAL .- Housed in a rugged extruded aluminium profile housing for panel mounting or free standing. Finished in anodized black colour. The frontal lens is mounted with a special rubber profile which provides the front part of the unit with an IP-65 protection. CONTROL SIGNALS .- Th ...

  • Omega LDP-126 - page 7

    Page : 6 OUTPUTS SERIAL OUTPUT . . . . . . . Output intended for transmission to the remote display fitted with a clock display as a slave clock display. Signal . . . . . . . . . . . . . . . . RS422 level 1200 baud fixed rate. One transmission each second while showing real time or run time. String . . . . . . . . . . . . . . . . . Transmits --NUL- ...

  • Omega LDP-126 - page 8

    Page : 7 6.- FRONT VIEW , DESCRIPTION Models LDP-126-C2 LDP-146-C2 Models LDP-124-C0 & C1 LDP-144-C0 & C1 Display seconds for model C0 Display minutes for model C1 colon Display minutes for model C0 Display hours for model C1 Display hours for model C2 Display minutes for model C2 7.- REAR VIEW , DESCRIPTION for all series Display seconds f ...

  • Omega LDP-126 - page 9

    Page : 8 8.- WIRING 8.1.- POWER SUPPLY, RECOMMENDED WIRING POWER SUPPLY 115 Vac (230 Vac Optional). FUSE and spare fuse . Main switch 8.2.- PROTECTION FUSES 8.3.- CONTROL LINES, ALARM AND SERIAL OUTPUT 1 8 9 15 Power Fuse Supply value 230 Vac 0.2 A 115 Vac 0.4 A TABLE 4 1 9 6 5 A : + Alarm B : No connection C : No connection D : - Alarm A B C D Ser ...

  • Omega LDP-126 - page 10

    Page : 9 8.5.- EXCITATION VOLTAGE FOR SENSORS The unit supplies the Excitation Voltage for sensors, through control lines connector. If the current required for the sensors installed is more than 100 mA then do not use this terminal. Install other external power supply. See paragraph 5 for technical specifications 9.- POWER-UP AND OPERA TION 9.1.- ...

  • Omega LDP-126 - page 11

    Page : 10 9.2.2.- CONNECTION EXAMPLES Different interlinking of the three control lines will produce different operating modes: Close contact A = reset and run Open contact A = stop Stop Start Reset GND Stop Start Reset GND Stop Start Reset GND With contact B opened close contact A = run open contact A = stop push contact B = reset A A A B B Push A ...

  • Omega LDP-126 - page 12

    Page : 11 Control board position for instruments series LDP-2X-CX Control board position for instruments series LDP-4X-CX 10.2.1- CONTROL BOARD POSITION 10.2.2- DIP SWITCH AND JUMPERS LOCATION JP5 JP9 JP10 JP1 JP2 JP3 JP4 ON OFF JP7 JP6 JP8 A B 10.2.3- DIP SWITCH CONFIGURATION Switch Switch position number OF F ON 1 Alarm Di sable Enable* 2 Run tim ...

  • Omega LDP-126 - page 13

    Page : 12 10.2.4- JUMPERS CONFIGURATION Function Close Jumper 220 Ω terminator resistor for the RS422 JP1 (By default opened) switch debounce of 5 Hz for the STOP line JP2* (By default closed) switch debounce of 5 Hz for the START line JP3* (By default closed) switch debounce of 5 Hz for the RESET line JP4* (By default closed) 10.2.5- SERIAL DATA ...

  • Omega LDP-126 - page 14

    Page : 13 1 1.- INST ALLA TION 1.- Prepare a panel cut-out with the dimensions indicated on paragraph 12. 2.- Slide the instrument (1) into the cut-out. 3.- Slide the two fixation pieces (3) with T shape by both lateral sides of the instrument, such as it is shown on the drawing below. 4.- Turn the screw bolt until it is pressed firmly against the ...

  • Omega LDP-126 - page 15

    JP1 JPA2 T S M48T 02-200PC1 1137A TI MEKEEPER TM RAM LI T HIU M BATT ERY MALA YSIA JP A3 JPA4 REM OVE IC4 SITUATIO N JUMPER JPA 2 JP1 Configuration Diagram. Charge conne ct ed Charge disconnecte d C.I.98/04 C.I.98/06 APPENDIX 1: MODEL LDP-1XX-CX AS SLA VE REPEA TER. FUNCTIONAL DESCRIPTION: Special configuration of Models LDP-1XX-CX for serial RS-42 ...

  • Omega LDP-126 - page 16

    Page : 15 m aster slave 12 4 - C 0 124-C1 12 6-C2 144-C 0 144-C1 146 -C2 LDP -124-C YE S NO YE S NO LDP -126-C NO YE S NO YE S LDP -144-C YE S NO YE S NO LDP -146-C NO YE S NO YE S COM PATIBI L IT Y TABLE AM ONG M ASTER-SLA VE A PPENDI X 2: TI M E-NE T CONFI GURA TI ON A ND CONNECT IONS . It is advisa ble to make t he T IME-N ET connecti ons as fol ...

  • Omega LDP-126 - page 17

    W ARRANTY/DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA ’ s customers rece ...

  • Omega LDP-126 - page 18

    Where Do I Find Everything I Need for Process Measurement and Control? OMEGA...Of Course! TEMPERA TURE ; Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies ; Wire: Thermocouple, RTD & Thermistor ; Calibrators & Ice Point References ; Recorders, Controllers & Process Monitors ; Infrared Pyrometers PRESSURE, ST ...

Fabricant Omega Catégorie Clock

Les documents que nous recevons du fabricant de l'appareilOmega LDP-126 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Omega
- manuels d’utilisations LDP-126
- fiches produit Omega
- dépliants
- ou étiquettes-énergie Omega LDP-126
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Omega LDP-126.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Omega LDP-126, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Omega LDP-126. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Omega LDP-126.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Omega LDP-126, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Omega LDP-126 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Omega LDP-126.

Le manuel d’utilisation complet Omega, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Omega LDP-126 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Omega LDP-126, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lOmega LDP-126 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Omega LDP-126 - qui devraient nous aider dans les premières étapes lors de l'utilisation Omega LDP-126
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Omega LDP-126
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Omega LDP-126 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Omega LDP-126?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Omega LDP-126, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Omega LDP-126 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)