  • Omega LDP-126 - page 1

    LDP-124, LDP-126, LDP-144 AND LDP-146 OPERATOR´S MANUAL FOR CLOCK MODELS http://www .omega.com e-mail: info @ omega.com User's Guide ...

  • Omega LDP-126 - page 2

    OMEGAnet  On-Line Service Internet e-mail http://www.omega.com info@omega.com Servicing North America: USA : One Omega drive, Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 Tel : (203) 359-1660 Fax : (203) 359 7700 e-mail : info@omega.com Canada : 976 Bergar Laval (Quebec) H7L 5A1 Tel : (514) 856-6928 Fax : (514) 856-6886 e-mail : info@omeg ...

  • Omega LDP-126 - page 3

    Page : 2 CONTENTS DESCRIPTION SECTION PAGE =========================================================================== IMPORTANT SAFETY CONSIDERATIONS 13 UNPACKING AND INSPECTION 24 MAIN FEATURES 34 MODELS 45 MODEL LDP-1XX-C0, DISPLAY TIME USING THE FORMAT MM : SS 4. 1 5 MODEL LDP-1XX-C1, DISPLAY TIME USING THE FORMAT HH : MM 4. 2 5 MODEL LDP-1XX-C ...

  • Omega LDP-126 - page 4

    Page : 3 INSTALLATION PRECAUTIONS.- The installation and the future use of this unit must be done by suit- able qualified person- nel. The unit has not AC (mains) switch, it will be in operation as soon as power is connected. The installation must incorporate an external main switch. The unit has a protection fuse incorporated on the AC socket, if ...

  • Omega LDP-126 - page 5

    Page : 4 2.- UNP ACKING AND INSPECTION It is advisable to do a detailed reading of this Manual before mounting the instrument. This Operator's Manual contains all the technical specifications : electricals as well as mechanics, both necessary to do a correct installation and also a good use of the instrument. At the same time the user will acq ...

  • Omega LDP-126 - page 6

    Page : 5 The common features for all series are the following: MECHANICAL .- Housed in a rugged extruded aluminium profile housing for panel mounting or free standing. Finished in anodized black colour. The frontal lens is mounted with a special rubber profile which provides the front part of the unit with an IP-65 protection. CONTROL SIGNALS .- Th ...

  • Omega LDP-126 - page 7

    Page : 6 OUTPUTS SERIAL OUTPUT . . . . . . . Output intended for transmission to the remote display fitted with a clock display as a slave clock display. Signal . . . . . . . . . . . . . . . . RS422 level 1200 baud fixed rate. One transmission each second while showing real time or run time. String . . . . . . . . . . . . . . . . . Transmits --NUL- ...

  • Omega LDP-126 - page 8

    Page : 7 6.- FRONT VIEW , DESCRIPTION Models LDP-126-C2 LDP-146-C2 Models LDP-124-C0 & C1 LDP-144-C0 & C1 Display seconds for model C0 Display minutes for model C1 colon Display minutes for model C0 Display hours for model C1 Display hours for model C2 Display minutes for model C2 7.- REAR VIEW , DESCRIPTION for all series Display seconds f ...

  • Omega LDP-126 - page 9

    Page : 8 8.- WIRING 8.1.- POWER SUPPLY, RECOMMENDED WIRING POWER SUPPLY 115 Vac (230 Vac Optional). FUSE and spare fuse . Main switch 8.2.- PROTECTION FUSES 8.3.- CONTROL LINES, ALARM AND SERIAL OUTPUT 1 8 9 15 Power Fuse Supply value 230 Vac 0.2 A 115 Vac 0.4 A TABLE 4 1 9 6 5 A : + Alarm B : No connection C : No connection D : - Alarm A B C D Ser ...

  • Omega LDP-126 - page 10

    Page : 9 8.5.- EXCITATION VOLTAGE FOR SENSORS The unit supplies the Excitation Voltage for sensors, through control lines connector. If the current required for the sensors installed is more than 100 mA then do not use this terminal. Install other external power supply. See paragraph 5 for technical specifications 9.- POWER-UP AND OPERA TION 9.1.- ...

  • Omega LDP-126 - page 11

    Page : 10 9.2.2.- CONNECTION EXAMPLES Different interlinking of the three control lines will produce different operating modes: Close contact A = reset and run Open contact A = stop Stop Start Reset GND Stop Start Reset GND Stop Start Reset GND With contact B opened close contact A = run open contact A = stop push contact B = reset A A A B B Push A ...

  • Omega LDP-126 - page 12

    Page : 11 Control board position for instruments series LDP-2X-CX Control board position for instruments series LDP-4X-CX 10.2.1- CONTROL BOARD POSITION 10.2.2- DIP SWITCH AND JUMPERS LOCATION JP5 JP9 JP10 JP1 JP2 JP3 JP4 ON OFF JP7 JP6 JP8 A B 10.2.3- DIP SWITCH CONFIGURATION Switch Switch position number OF F ON 1 Alarm Di sable Enable* 2 Run tim ...

  • Omega LDP-126 - page 13

    Page : 12 10.2.4- JUMPERS CONFIGURATION Function Close Jumper 220 Ω terminator resistor for the RS422 JP1 (By default opened) switch debounce of 5 Hz for the STOP line JP2* (By default closed) switch debounce of 5 Hz for the START line JP3* (By default closed) switch debounce of 5 Hz for the RESET line JP4* (By default closed) 10.2.5- SERIAL DATA ...

  • Omega LDP-126 - page 14

    Page : 13 1 1.- INST ALLA TION 1.- Prepare a panel cut-out with the dimensions indicated on paragraph 12. 2.- Slide the instrument (1) into the cut-out. 3.- Slide the two fixation pieces (3) with T shape by both lateral sides of the instrument, such as it is shown on the drawing below. 4.- Turn the screw bolt until it is pressed firmly against the ...

  • Omega LDP-126 - page 15

    JP1 JPA2 T S M48T 02-200PC1 1137A TI MEKEEPER TM RAM LI T HIU M BATT ERY MALA YSIA JP A3 JPA4 REM OVE IC4 SITUATIO N JUMPER JPA 2 JP1 Configuration Diagram. Charge conne ct ed Charge disconnecte d C.I.98/04 C.I.98/06 APPENDIX 1: MODEL LDP-1XX-CX AS SLA VE REPEA TER. FUNCTIONAL DESCRIPTION: Special configuration of Models LDP-1XX-CX for serial RS-42 ...

  • Omega LDP-126 - page 16

    Page : 15 m aster slave 12 4 - C 0 124-C1 12 6-C2 144-C 0 144-C1 146 -C2 LDP -124-C YE S NO YE S NO LDP -126-C NO YE S NO YE S LDP -144-C YE S NO YE S NO LDP -146-C NO YE S NO YE S COM PATIBI L IT Y TABLE AM ONG M ASTER-SLA VE A PPENDI X 2: TI M E-NE T CONFI GURA TI ON A ND CONNECT IONS . It is advisa ble to make t he T IME-N ET connecti ons as fol ...

  • Omega LDP-126 - page 17

    W ARRANTY/DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA ’ s customers rece ...

  • Omega LDP-126 - page 18

    Where Do I Find Everything I Need for Process Measurement and Control? OMEGA...Of Course! TEMPERA TURE ; Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies ; Wire: Thermocouple, RTD & Thermistor ; Calibrators & Ice Point References ; Recorders, Controllers & Process Monitors ; Infrared Pyrometers PRESSURE, ST ...

メーカー Omega カテゴリー Clock

Omega LDP-126のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- LDP-126の取扱説明書
- Omegaの製品カード
- パンフレット
- またはOmega LDP-126の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Omega LDP-126の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Omega LDP-126の取り付け説明書、サービスマニュアル、簡易説明書、またはOmega LDP-126のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Omega LDP-126の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Omega LDP-126デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがOmega LDP-126を使用するのを助ける技術的文書のことです。説明書は通常、全てのOmega LDP-126ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Omegaの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Omega LDP-126の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははOmega LDP-126の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Omega LDP-126に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Omega LDP-126デバイスの基本機能を使うにあたってのヒント。 Omega LDP-126のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Omega LDP-126に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるOmega LDP-126のメーカー/サービスへの連絡先に関する情報。

Omega LDP-126についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもOmega LDP-126の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがOmega LDP-126で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください