Manuel d’utilisation Heat & Glo LifeStyle 50

52 pages 4.87 mb
Télécharger

Aller à la page of 52

Summary
  • Heat & Glo LifeStyle 50 - page 1

    1 Owner ’ s Manual Installation and Operation Models: RUTHERFORD-50 Wood Burning Fireplace DO NOT DISCARD THIS MANUAL NOTICE • Important operating and maintenance instructions included. • Leave this manual with party responsible for use and operation. • Read, understand and follow these instructions for safe installation and operation. DO N ...

  • Heat & Glo LifeStyle 50 - page 2

    2 Read this manual before installing or operating this fi replace. Please retain this owner ’ s manual for future reference. Homeowner Reference Information Model Name: Date purchased/installed: Serial Number: Location on fi replace: Dealership purchased from: Dealer phone: Notes: We recommend that you record the following pertinent information ...

  • Heat & Glo LifeStyle 50 - page 3

    3 Note: An arrow ( ¨ ) found in the text signi fi es change in content. Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury . • CAUTION! Indicates a hazardous situat ...

  • Heat & Glo LifeStyle 50 - page 4

    4 Heat & Glo • RUTHERFORD-50 • 4059-333 Rev C • 06/08 W ARRANTY FOR HEA T & GLO FIREPLACES The limited warranty will not become effective until you have mailed the completed warranty card to: Hearth & Home T echnologies Inc. 20802 Kensington Blvd., Lakeville, MN 55044. This card must be mailed within 60 days of the fireplace insta ...

  • Heat & Glo LifeStyle 50 - page 5

    5 1 1 Listing and Code Appro v als NOTICE: This fi replace is tested and approved as a decorative fi replace. It should not be factored as a primary heat source in residential heating calculations. W ARNING! Risk of Fire! Hearth & Home T echnologies disclaims any responsibility for , and the warranty and agency listing will be voided by the a ...

  • Heat & Glo LifeStyle 50 - page 6

    6 2 2 Operat ing Instr uct ions W ARNING! DO NOT operate fi replace before reading and understanding operating instructions. Failure to operate fi replace according to operating instructions could cause fi re or injury . User Guide W ARNING Hot screen/mesh and glass doors will cause burns. • DO NOT touch screen/mesh or glass doors until cooled ...

  • Heat & Glo LifeStyle 50 - page 7

    7 D. Grate This fi replace is designed to be used with the grate sup- plied with this unit or one approved by HHT . The grate will deteriorate over time and will need occasional replacement. W ARNING! Risk of Fire! Use only the factory-supplied integral grate. • Keeps logs in place. • Allows proper air circulation around the fi re. E. Firescr ...

  • Heat & Glo LifeStyle 50 - page 8

    8 W ARNING! Risk of Fire and Smoke! Fireplaces equipped with doors should be operated only with doors fully open or doors fully closed. If doors are left partly open, gas and fl ame may be drawn out of the fi replace opening. FULL Y OPEN CORRECT P ARTL Y CLOSED INCORRECT P ARTL Y OPEN INCORRECT FULL Y CLOSED CORRECT Figure 2.2 Operating Positions ...

  • Heat & Glo LifeStyle 50 - page 9

    9 M. Wood Fuel Hardwood vs Softwood Y our fi replace performance depends on the quality of the fi rewood you use. • Seasoned wood contains about 8,000 BTUs per pound . • Hard woods are more dense than soft woods. • Hard woods contain 60% more BTUs than soft woods. • Hard woods require more time to season, burn slower and are harder to ign ...

  • Heat & Glo LifeStyle 50 - page 10

    10 3 3 Maintainance and Ser vice A. Disposal of Ashes Frequency: When they reach bottom of grate By: Homeowner B. Chimney Inspection/Cleaning Frequency: At least twice a year during heating season or as recommended by a certi fi ed chimney sweep By: Certi fi ed chimney sweep Figure 3.1 Chimney & T ermination Cap Cleaning W ARNING! Risk of Fir ...

  • Heat & Glo LifeStyle 50 - page 11

    11 C. Check Firebox Molded Brick Panel Frequency: After each ash removal By: Homeowner D. Inspect Grate Frequency: After each ash removal By: Homeowner Inspect grate for: • W arping or sagging 1-1/2 in. (38 mm) or more • Broken welds • Burn-through of grate bars For safe operation, replace only with the approved grate from Hearth & Homes ...

  • Heat & Glo LifeStyle 50 - page 12

    12 4 4 T roubleshooting Guide Start Fire Problems Possible Cause Solution Can’t get fi re started Excessive smoke or spillage Burns too slowly Smolders, sizzles Not enough kindling/paper or no kindling/paper Use dry kindling, more paper . Arrange kindling & wood for air movement. Damper closed/not fully open Open damper . Not enough air for ...

  • Heat & Glo LifeStyle 50 - page 13

    13 Additional lateral support for chimney above roof (or enclosed in chase) if needed (Section 8) Ceiling firestop on floor of attic (Section 8) Support straps on rafter supports chimney (not shown) (Section 8) T ermination cap (Sections 8) Chimney penetrates roof preferably without affecting roof rafters (Section 8) Framing headed off in ceiling j ...

  • Heat & Glo LifeStyle 50 - page 14

    14 B. Design and Installation Considerations Draft is the pressure difference needed to vent fi replaces successfully . When a fi replace is drafting successfully , all combustion by-products are exiting the home through the chimney . Considerations for successful draft include: • Preventing negative pressure • Location of fi replace and chi ...

  • Heat & Glo LifeStyle 50 - page 15

    15 Marginal Location: • Below peak Location NOT recommended: • Not the highest point of the roof • Wind loading possible Multi-level Roofs Windward Leeward Recommended: Outside Air Intake on windward side NOT recommended: Outside Air Intake on leeward side Recommended Location: • Above peak Recommended: • Insulated exterior chase in coole ...

  • Heat & Glo LifeStyle 50 - page 16

    16 Before beginning the installation be sure the following tools and building supplies are available: Reciprocating saw Framing material Pliers Non-combustible sealant Hammer Gloves Phillips screwdriver Framing square Flat blade screwdriver Electric drill and bits Plumb line Safety glasses Level T ape measure 1/2-3/4 in. length, #6 or #8 self-drill ...

  • Heat & Glo LifeStyle 50 - page 17

    17 6 6 F raming & Clearances A F D B C 5/8 in. (16 mm) all configurations 1-1/2 in. min. air space from fireplace to combustible materials. 1/2 in. min. air space at nailing flanges. Note: In an exterior chase or projecting into a garage Across a corner As a room divider Along a wall 92 in. (2337 mm) G B E Note: In addition to these framing dim ...

  • Heat & Glo LifeStyle 50 - page 18

    18 B. Clearances W ARNING! Risk of Fire! Y ou must comply with all minimum air space clearances to combustibles as speci fi ed in Fig- ure 6.2. DO NOT pack required air spaces with insulation or other materials. Heat & Glo • RUTHERFORD-50 • 4059-333 Rev C • 06/08 (insulation) 0 in. to level of standoffs Attic Insulation Shield (ceiling) ...

  • Heat & Glo LifeStyle 50 - page 19

    19 60-7/8 in. 50 in. 18 1/2 in. [470 mm] 19 3/4 in. [500 mm] 4 in. [102 mm] 50° angle 39° angle 24 in. [610 mm] BRICK FRONT FLUSH FRONT 24 in. [610 mm] 22 3/8 in. [568 mm] Note: Grid depicts 1 inch squares. Figure 6.3 Combustible Mantel Leg or Wall Projections (acceptable on both sides of opening) C. Sidewalls/Surrounds • Locate adjacent combus ...

  • Heat & Glo LifeStyle 50 - page 20

    20 7 7 Installation of Fireplace CAUTION! Risk of Cuts/Abrasions. Wear protective gloves and safety glasses during installation. Sheet metal edges are sharp. A. Things to Consider • Location(s) of outside air kit(s) • Gas line piping B. Position the Fireplace • Place the fi replace on a continuous fl at surface. • Follow framing instructi ...

  • Heat & Glo LifeStyle 50 - page 21

    21 Outlet placed higher than 3 ft below the termination cap Attic space Garage or combustible liquids storage Outlet blocked by snow , leaves, etc. Clear area outside house or in ventilated crawl space YES NO NO NO NO Factory-built fireplace Figure 7.4 Outside Combustion Air Placement Heat & Glo • RUTHERFORD-50 • 4059-333 Rev C • 06/08 3 ...

  • Heat & Glo LifeStyle 50 - page 22

    22 Outside Air Hood 2 Wire T ies Flexible Duct (not supplied) Figure 7.5 Outside Air Installation E. Install Outside Air Kit • Keep duct runs short and straight to minimize restriction. • The outside air kits must be installed on both sides of the fi replace. W ARNING! Outside air kits must be installed on both sides of the fi replace to prev ...

  • Heat & Glo LifeStyle 50 - page 23

    23 Figure 8.1 T ypical Chimney System - Guidelines for Chimney System Installation 8 8 Ch imney Assembly NOTICE: Chimney performance may vary . • T rees, buildings, roof lines and wind conditions affect performance. • Chimney height may need adjustment if smoking or overdraft occurs. Heat & Glo • RUTHERFORD-50 • 4059-333 Rev C • 06/08 ...

  • Heat & Glo LifeStyle 50 - page 24

    24 T ermination Cap Storm Collar Chase T op Flashing Chase T op Collar (4) Roof Radiation Shields Chimney Section Attic Insulation Shield & Collar Square Frame Firestop Chimney Square Frame Firestop 74 1/8 in. (1883 mm) Effective Height Figure 8.2 A. Chimney Requirements Measure vertical distances from the base of the fi replace. W ARNING! Ris ...

  • Heat & Glo LifeStyle 50 - page 25

    25 A MAJOR CAUSE OF VENT RELA TED FIRES IS F AIL- URE T O MAINT AIN REQUIRED CLEARANCES (AIR SP ACES) T O COMBUSTIBLE MA TERIALS. IT IS OF THE UTMOST IMPOR T ANCE THA T DURACHIMNEY II BE INST ALLED ONL Y IN ACCORDANCE WITH THESE INSTRUCTIONS. B. Clearances Always allow at least a 2-inch clearance between Dura- Chimney II Pipe and any combustible ma ...

  • Heat & Glo LifeStyle 50 - page 26

    26 G. Assemble Chimney Sections Attach the fi rst chimney section or offset onto the top of the fi replace (Figure 8.4). Sheet metal screws are required to connect Chimney Section to Anchor Plate. Continue to add additional sections of chimney as needed. Use a W all Strap every eight (8) feet of chimney height. For each additional Chimney Section ...

  • Heat & Glo LifeStyle 50 - page 27

    27 I. Install Attic Insulation Shield The Attic Insulation Shield must be installed where the chimney passes into an attic. Its purpose is to prevent debris and insulation from getting too close to the chimney . In attic areas where this shield cannot fi t, or is not used you must enclose the attic portion of the chimney in a framed enclosure. If ...

  • Heat & Glo LifeStyle 50 - page 28

    28 K. Finish T op Apply a non-hardening waterproof sealant around the chimney at the point where the Storm Collar will meet the chimney just above the fl ashing (Figure 8.14). Slide the Storm Collar down over the chimney to the top of the fl ash- ing. The Storm Collar must be installed 1” of f the Chase T op Flashing to provide proper ventilati ...

  • Heat & Glo LifeStyle 50 - page 29

    29 N. Chimney T ermination Requirements • Install a cap approved and listed for this fi replace system. • Locate cap where it will not become plugged by snow or other materials. • Locate cap away from trees or other structures. • The bottom of the termination cap must be at least 3 ft (.91 m) above the roof AND at least 2 ft (.61 m) above ...

  • Heat & Glo LifeStyle 50 - page 30

    30 9 9 Chase Installations Ceiling Firestop Chase T op Flashing T ermination Cap False Ceiling Insulation in the outside walls of the chase Attic Insulation Shield Chimney Ceiling Firestop T abs False Ceiling False Ceiling Insulation Insulation Figure 9.1 Chase Assembly 1 2 3 1. Fireplace and chimney enclosed in an exterior chase. 2. Chimney offset ...

  • Heat & Glo LifeStyle 50 - page 31

    31 1/2 in. air space established by spacers Chase T op Flashing 1/2 in. Air Space (Not furnished by Dura-V ent) Fabricated Spaces Locally 1/2 Storm collar must be installed 1 in. off chase top Figure 9.4 Chase T op Construction B. Install Fireplace & Chimney Install as per Sections 7 and 8. C. Install Chase T op Flashing • Y ou MUST use a cha ...

  • Heat & Glo LifeStyle 50 - page 32

    32 Allow a 1 in. (25 mm) air gap between storm collar and chase top flashing 1/2 in. (13 mm) air space established by spacers 1/2 in. overhang 14 in. (345 mm) diameter chimney must extend at least 6 in. (152 mm) above chase top flashing. DuraChimney II Pipe 1/2 in. (13 mm) Field-fabricated spacers for chase top flashing Chase T op Flashing or Chase ...

  • Heat & Glo LifeStyle 50 - page 33

    33 B. House Style Shroud • Field-fabricated spacers (1/2 in./13 mm tall, 24 ga/.024 in. galvanized steel) must be used to support the chase top fl ashing or chase pan, in order to provide air fl ow . • 14 in. (345 mm) DuraChimney II pipe must extend at least 6 in. (152 mm) above the chase pan/ fl ashing. • A DuraChimney II cap must be used ...

  • Heat & Glo LifeStyle 50 - page 34

    34 C. Arch / Mailbox Style Shroud The arch or mailbox style shroud generally has two solid sides and a solid top. The exhaust openings are on the two open ends of the arch (Figure 10.3). T able 10.2 lists the minimum shroud dimensions, the minimum open area per side, and the minimum total open area for the shroud. Shaded area represents screened op ...

  • Heat & Glo LifeStyle 50 - page 35

    35 1 1 11 Inst allation of Molded Br ick Panel A. Install Hearth Molded Brick Panel • Place hearth panel into the fi replace. C. Install Back Molded Brick Panel-T raditional • Refer to Figure 1 1.1. • Set the grate brackets in place, 26.5 in. (673 mm) center to center . • Install the lower back panel. Center from side to side. • Install ...

  • Heat & Glo LifeStyle 50 - page 36

    36 Figure 1 1.2 Herringbone Molded Brick Panel Note: Use T -brac ke ts as templates and dr ill pilot holes into the inner shell with the dr ill bit provided. Side panels must be installed fi rst. E. Install Back Molded Brick Panel-Herring- bone • Refer to Figure 1 1.2. • Set the grate brackets in place, 26.5 in. (673 mm) center to center . • ...

  • Heat & Glo LifeStyle 50 - page 37

    37 Center of Fireplace Opening Round end of Rod through rings, then into Screen Rod Clip The noncombustible finishing material across the top of the fireplace opening will be even with the lower edge of the metal face. Noncombustible finishing materials MUST overlap side faces by 1 1/4 in. (32 mm) to cover the edges of the refractory . Finished ope ...

  • Heat & Glo LifeStyle 50 - page 38

    38 1 2 12 Fi ni shi n g A. Non-Combustible Materials • Materials which will not ignite and burn, composed of any combination of the following: - Steel - Iron - Brick - T ile - Concrete - Slate - Glass - Plasters • Materials reported as passing ASTM E 136, Standard T est Method for Behavior of Metals, in a V ertical T ube Furnace at 750° C B. C ...

  • Heat & Glo LifeStyle 50 - page 39

    39 IMPORT ANT ! H ear th ex tension design must be determined before installation of fi replac e. Floor Noncombustible Framing Material Noncombustible Finishing Material Protective Metal Hearth Strips Double HX4 or equivalent & 1/2 in. Durock Bottom of fireplace opening; finished hearth surface must NOT be above it. The bottom of the fireplace ...

  • Heat & Glo LifeStyle 50 - page 40

    40 Non-combustible Sealant After completing the framing and applying the facing mate- rials over the framing, a bead of non-combustible sealant must be used to close off any gaps at the top and sides between the fi replace and hearth. Non-combustible Sealant Noncombustible Material Protective Metal Hearth Strip 30 in. Min. Hearth Extension 1 in. ( ...

  • Heat & Glo LifeStyle 50 - page 41

    41 These surfaces may be covered with non-combustible material. Non-combustible sealant. D. Finishing Material Refer to Sections 12.A. and Sections 12.B. for combus- tible/noncombustible materials. Refer to Figure 12.10 for noncombustible zone. W ARNING! Risk of Fire! Y ou must maintain clearances. • Use only non-combustible framing material belo ...

  • Heat & Glo LifeStyle 50 - page 42

    42 E. Combustible Mantel • See Figure 12.1 1. • A combustible mantel may be positioned no lower than 22 in. (508 mm) above the top of the fi replace opening. • A combustible mantel may have a maximum depth of 12 in. (305 mm). • Combustible trim and mantels cannot be placed within 6 in. (152 mm) of the fi replace opening (top or sides). ? ...

  • Heat & Glo LifeStyle 50 - page 43

    43 F . Sidewalls/Surrounds • Adjacent combustible sidewalls must be located a minimum of 24 in. (305 mm) from the fi replace opening. • Combustible mantel legs, surrounds and stub walls may be constructed per Figure 12.12. 60-7/8 in. 50 in. 18 1/2 in. [470 mm] 19 3/4 in. [500 mm] 4 in. [102 mm] 50° angle 39° angle 24 in. [610 mm] BRICK FRONT ...

  • Heat & Glo LifeStyle 50 - page 44

    44 A. Gas Log/Lighter Provision W ARNING! Fire and/or Asphyxiation Risk! Use with solid wood fuel or decorative gas appliance only . Gas fi re gener- ates fumes. • DO NOT install unvented gas logs • Damper must be locked fully open when gas logs are installed Firebox Repack Insulation Knockout Combustible Materials Maintain air clearance to co ...

  • Heat & Glo LifeStyle 50 - page 45

    45 1 4 14 Reference Materials A. Fireplace Dimensions 16 1/8 in. 408 mm Gas Line Knockout 1 1 1/8 in. 282 mm 6 7/8 in. 175 mm 5 in. 129 mm 50 in. 1270 mm 60 7/8 in. 1546 mm 3 3/4 in. 97 mm 38 in. 965 mm 54 in. 1372 mm 74 1/8 in. 1883 mm 70 3/4 in. 1797 mm 16 1/8 in. 408 mm 1 1 1/8 in. 282 mm 6 7/8 in. 175 mm 5 in. 129 mm 45 1/8 in. 1 146 mm 11 i n ...

  • Heat & Glo LifeStyle 50 - page 46

    46 B. Fireplace Components 20 in. (508 mm) 66 in. (1676 mm) 1/2 in. (13 mm) HX4 Hearth Extension (3 required/shipped separately) Outside Air Kit (2 supplied) GR39 Grate (supplied) ID6 Insulated Duct UD6 Uninsulated Duct 42 in. (1067 mm) 6 in. (152.4 mm) i.d. 42 in. (1067 mm) 6 in. (152.4 mm) i.d. (Required/shipped separately) DFG4050 Series Glass D ...

  • Heat & Glo LifeStyle 50 - page 47

    47 C. Chimney Components Catalog # Description 14DCA-12 Pipe 12 inch 14DCA-18 Pipe 18 inch 14DCA-36 Pipe 36 inch 14DCA-48 Pipe 48 inch 14 DCA-E15 15 degree Elbow 14DCA-E30 30 dectree Elbow 14DCA-ES Elbow Strap 14DCA-SS Supplementary Support 14DCA-ST Stabilizer 14DCA-FS Firestop 14DCA-IS Insulation Shield RF-1470 Roof Flashing 14DCA-RRS Roof Radiati ...

  • Heat & Glo LifeStyle 50 - page 48

    48 C. Service Parts RUTHERFORD-50 Service Parts 1 2 3 4 8 5 6 7 16 15 18 8 19 20 17 9 8 13 11 14 10 12 Heat & Glo • RUTHERFORD-50 • 4059-333 Rev C • 06/08 ¨ ...

  • Heat & Glo LifeStyle 50 - page 49

    49 RUTHERFORD-50 Service Parts IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer . Stocked at Depot ITEM DESCRIPTION SERIAL # P ART NUMBER 1 Damper Blade Assembly 4059-030 N ...

  • Heat & Glo LifeStyle 50 - page 50

    50 This page intentionally left blank. Heat & Glo • RUTHERFORD-50 • 4059-333 Rev C • 06/08 ...

  • Heat & Glo LifeStyle 50 - page 51

    51 This page intentionally left blank. Heat & Glo • RUTHERFORD-50 • 4059-333 Rev C • 06/08 ...

  • Heat & Glo LifeStyle 50 - page 52

    52 – NOTES – D. Contact Information DO NOT DISCARD THIS MANUAL CAUTION • Important operating and maintenance instructions included. • Leave this manual with party responsible for use and operation. • Read, understand and follow these instructions for safe installation and operation. DO NOT DISCARD This product may be covered by one or mor ...

Fabricant Heat & Glo LifeStyle Catégorie Indoor Fireplace

Les documents que nous recevons du fabricant de l'appareilHeat & Glo LifeStyle 50 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Heat & Glo LifeStyle
- manuels d’utilisations 50
- fiches produit Heat & Glo LifeStyle
- dépliants
- ou étiquettes-énergie Heat & Glo LifeStyle 50
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Heat & Glo LifeStyle 50.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Heat & Glo LifeStyle 50, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Heat & Glo LifeStyle 50. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Heat & Glo LifeStyle 50.

Manuel d’utilisation complet de l’appareil Heat & Glo LifeStyle 50, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Heat & Glo LifeStyle 50 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Heat & Glo LifeStyle 50.

Le manuel d’utilisation complet Heat & Glo LifeStyle, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Heat & Glo LifeStyle 50 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Heat & Glo LifeStyle 50, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lHeat & Glo LifeStyle 50 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Heat & Glo LifeStyle 50 - qui devraient nous aider dans les premières étapes lors de l'utilisation Heat & Glo LifeStyle 50
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Heat & Glo LifeStyle 50
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Heat & Glo LifeStyle 50 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Heat & Glo LifeStyle 50?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Heat & Glo LifeStyle 50, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Heat & Glo LifeStyle 50 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)