Manuel d’utilisation Oregon Scientific BAR182HG

14 pages 0.29 mb
Télécharger

Aller à la page of 14

Summary
  • Oregon Scientific BAR182HG - page 1

    1 EN DIGIT AL WEA THER FORECASTER WITH REMOTE THERMO-HYGRO SENSOR AND ALARM CLOCK MODEL NO.: BAA182HG USER’S MANUAL INTRODUCTION Congratulations on your purchase of the W eather forecaster with cable free sensor and clock (BAR182HG). This unit has a large four-line liquid crystal display (LCD) for displaying weather forecast information, in/outdo ...

  • Oregon Scientific BAR182HG - page 2

    2 EN A . FRONT DISPLA Y A four line easy-to-read LCD A1. WEA THER FORECAST WINDOW Graphically illustrates a weather forecast B. [ ] BA TTERY-LOW INDICA TOR Activates when the remote-sensor or main unit battery power is low C. [ 1 ] / [ 2 ] ALARM-ON ICONS Appears when the alarm is activated D . [((1))] / [((2))] ALARM ICONS Appears when the respecti ...

  • Oregon Scientific BAR182HG - page 3

    3 EN FEA TURES: REMOTE THERMO-HYGRO SENSOR A. TWO-LINE LCD Displays the current temperature and humidity monitored by the remote unit B . LED INDICA TOR Flashes when the remote sensor transmits a reading C. °C/°F SLIDE SWITCH Selects between Centigrade (°C) and Fahrenheit (°F) D . CHANNEL SLIDE SWITCH Select the remote sensor Channel 1, Channel ...

  • Oregon Scientific BAR182HG - page 4

    4 EN easier synchronization between the transmission and reception of signals. 4. Position the remote unit and main unit within effective transmission range, which, in usual circumstances, is up to 30 meters. Note that the effective range is vastly affected by the building materials and where the main and remote units are positioned. Try various se ...

  • Oregon Scientific BAR182HG - page 5

    5 EN LOW BA TTERY W ARNING When it is time to replace batteries, the respective low-battery indicator will show up when the respective channel is selected. HOW TO USE THE T ABLE ST AND OR W ALL MOUNTING The main unit has a removable table stand, which when connected, can support the unit on a flat surface. Or you can remove the stand and mount the ...

  • Oregon Scientific BAR182HG - page 6

    6 EN T o force a signal search: Press and hold [CHANNEL] & [MEM] for 2-seconds to enforce a 3-minute search. This is useful in synchronizing the transmission and reception of the remote and main units. Repeat this step whenever you find discrepancies between the reading shown on the main unit and that on the respective remote unit. HOW TO CHECK ...

  • Oregon Scientific BAR182HG - page 7

    7 EN HOW TO READ THE KINETIC W A VE DISPLA Y The kinetic wave display shows the signal receiving status of the main unit. There are three possible forms: The unit is in searching mode. Transmission data are securely registered. No signal received in search mode. REMOTE SENSOR SCANNING The unit can be set to automatically scan and display readings f ...

  • Oregon Scientific BAR182HG - page 8

    8 EN TEMPERA TURE, HUMIDITY & PRESSURE TREND INDICA T ORS The temperature-trend, humidity-trend and pressure trend indicators show the trends of collected readings. Arrows indicate a rising, steady or falling trend. Note: If the readings goes above or below the measuring range of the main unit or the remote unit ( stated in specification), the ...

  • Oregon Scientific BAR182HG - page 9

    9 EN The high-low displays are as follows: T o set a high or low temperature or humidity alarm: 1. Press [HI/LO] , channel-1 will be displayed. 2. Press [ ] to set the temperature or humidity limit. Each press will increase increments by one degree or percentage. Press and hold the button for a rapid-scrolling sequence by increments of five. Note: ...

  • Oregon Scientific BAR182HG - page 10

    10 EN Cloudy Sunny Forecast Rainy Slightly Cloudy Indicator displays on the unit NOTE: 1. The accuracy of a general pressure-based weather forecast is about 70% to 75%. 2. The weather forecasts from this unit are predictions that cover the next 12 to 24 hours. It may not necessarily reflect the current situation. 3. The “Sunny” icon, as applies ...

  • Oregon Scientific BAR182HG - page 11

    11 EN For the 2nd time zone, which is indicated by the ZONE icon, enter the hour offset using the [ ] and [ ] (CLOCK) buttons and the BAA182HG will calculate the second zone-time accordingly . If there is an item you do not wish to change, simply press [ MODE] to bypass the item. When you are done, press [ MODE ] to exit. The display will return to ...

  • Oregon Scientific BAR182HG - page 12

    12 EN MAINTENANCE When handled properly , this unit is engineered to give you years of satisfactory service. Here are a few product care instructions: 1. Do not immerse the unit in water. If the unit comes in contact with water, dry it immediately with a soft lint-free cloth. 2. Do not clean the unit with abrasive or corrosive materials. Abrasive c ...

  • Oregon Scientific BAR182HG - page 13

    13 EN NOTE ON COMPLIANCE This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operations. Warning: Changes or modifications to this unit n ...

  • Oregon Scientific BAR182HG - page 14

    14 EN W ARRANTY This product is warranted to be free of manufacturing defects for a period of 1 year from date of retail purchase. Defective product should be directed to the place of retail purchase for exchange. Should this not be possible, contact our customer care department for assistance and a return material authorization. No returns may be ...

Fabricant Oregon Scientific Catégorie Radar Detector

Les documents que nous recevons du fabricant de l'appareilOregon Scientific BAR182HG peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Oregon Scientific
- manuels d’utilisations BAR182HG
- fiches produit Oregon Scientific
- dépliants
- ou étiquettes-énergie Oregon Scientific BAR182HG
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Oregon Scientific BAR182HG.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Oregon Scientific BAR182HG, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Oregon Scientific BAR182HG. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Oregon Scientific BAR182HG.

Manuel d’utilisation complet de l’appareil Oregon Scientific BAR182HG, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Oregon Scientific BAR182HG par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Oregon Scientific BAR182HG.

Le manuel d’utilisation complet Oregon Scientific, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Oregon Scientific BAR182HG - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Oregon Scientific BAR182HG, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lOregon Scientific BAR182HG qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Oregon Scientific BAR182HG - qui devraient nous aider dans les premières étapes lors de l'utilisation Oregon Scientific BAR182HG
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Oregon Scientific BAR182HG
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Oregon Scientific BAR182HG dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Oregon Scientific BAR182HG?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Oregon Scientific BAR182HG, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Oregon Scientific BAR182HG il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)