Manuel d’utilisation Emerson 5081T-FF/FI

24 pages 0.97 mb
Télécharger

Aller à la page of 24

Summary
  • Emerson 5081T-FF/FI - page 1

    Model 5081T -FF/FI Instruction Sheet PN 51A-5081T -FF/FI/rev .A November 2005 Y our purchase from Rosemount Analytical, Inc. has result- ed in one of the finest instruments available for your p ar- ticular application. These instrument s have been designed, and tested to meet many national and interna- tional standards. Experience indicates that it ...

  • Emerson 5081T-FF/FI - page 2

    PHYSICAL SPECIFICA TIONS HOUSING: Epoxy-polyester painted over low-copper alu- minum. Neoprene O-rings on cover . 160.5 mm x 175.3 mm x 161.3 mm (6.3 in. x 6.9 in. x 6.4 in.) DIAMETER: 155.4 mm (6.1 in.) ELECTRICAL CONDUIT OPENINGS: 3/4 in. FNPT POWER SUPPL Y AND LOAD: A power supply voltage of 9 Vdc to 32 Vdc at 22 mA is required; Intrinsically Sa ...

  • Emerson 5081T-FF/FI - page 3

    3 3 MODEL 5081T -FF/FI SPECIFICA TIONS TRANSMITTER DISPLA Y DURING CALIBRA TION AND PROGRAMMING (FIGURE 1) 1. Continuous display of conductivity , % concentration, or custom reading. 2. Units: µS/cm, mS/cm, ppm, %, or none. 3. Current menu appears here. 4. Submenus, prompts, and diagnostic readings appear hear . 5. Commands available in each subme ...

  • Emerson 5081T-FF/FI - page 4

    4 U1 7 :! <[9:1 -E< / ! 922<U '"*#=22 /1[[! /9P<U <Q2U 4-SG U<[9:1 2D>[=T '""" 25.0C 12.00mA CAL key PROG key DIAG key HOLD key Model 5081T -FF/FI Process Display Screen µS/cm /-[5ES-U1 /1[[! /9P<U <1P<9S! " U1 7 :! -G6 U1 7 : G5<:[-A <1U>:! /V<= G12->[= PROGRAM Proc ...

  • Emerson 5081T-FF/FI - page 5

    MODEL 5081T -FF/FI DEF AUL T SETTINGS V ARIABLE NAME MNEMONIC F ACTOR Y SETTINGS CUSTOMER SETTINGS Program Menu T emperature UH OR Auto temperature compensation UDVUQ on ___________ Manual temperature UODP 25.0°C (overridden by auto) ___________ T emperature compensation algorithm /97: ( [LPHDS or P9P1 ) LInEAr ___________ Display GLTRND Y Measure ...

  • Emerson 5081T-FF/FI - page 6

    6 MODEL 5081T -FF/FI WIRING WIRING Wire sensor as shown below in Figure 2. Keep sensor wiring separate from power wiring. For best EMI/RFI protection, use shielded output signal cable in an earth-grounded metal conduit. Refer to the sensor instruction manual for more det ails. FIGURE 2. Wiring Model 5081T -FF/FI ...

  • Emerson 5081T-FF/FI - page 7

    7 7 MODEL 5081T -FF/FI WIRING WIRING THROUGH A JUNCTION BOX The sensor can be wired to the analyzer through a remote junction box (PN 23550-00). Wire the extension cable and sensor cable point-to-point. Refer to the sensor instruction manual for more details. Factory-terminated (PN 23747-00) and unterminated (PN 9200275) connecting cable are availa ...

  • Emerson 5081T-FF/FI - page 8

    8 MODEL 5081T -FF/FI INST ALLA TION INST ALLA TION UNP ACKING AND INSPECTION Inspect the shipping container . If it is damaged, cont act the shipper immediately for instructions. Save the box. If there is no apparent damage, unp ack the container . Be sure all items shown on the packing list are present. If items are missing, notify Rosemount Analy ...

  • Emerson 5081T-FF/FI - page 9

    9 ...

  • Emerson 5081T-FF/FI - page 10

    10 ...

  • Emerson 5081T-FF/FI - page 11

    11 ...

  • Emerson 5081T-FF/FI - page 12

    1 1 2 2 ...

  • Emerson 5081T-FF/FI - page 13

    13 ...

  • Emerson 5081T-FF/FI - page 14

    1 1 4 4 FM A 5/6/04 J. FLOCK 5/6/04 J. FLOCK .140 ±. 0 0 5 1.30 ±. 0 2 .650 ±. 0 15 .125 2.180 ±. 0 0 5 2.56 ±. 0 2 .120 ±. 0 15 Ø .125 R .25 5-6-04 89 33 4 4 FINISH:SILKSCREEN BLACK EPOX Y PAINT (BAKED). 5081-T-FI-67 MODEL 5081-T-FI HARDNES S BRINEL L 190 . BE ANNEALED & PASSIVATED. MAX IMUM STEEL .015+/-.005 THICK. MATERIAL TO 1 MATERI ...

  • Emerson 5081T-FF/FI - page 15

    1 1 5 5 5/6/04 J. FLOCK 5/6/04 J. FLOCK 70°C MA X CLASS III, DI V 1 CLASS II, DIV 1, GPS E-G CLASS I, DIV 1, GPS B-D HAZARDOU S AREA 3 R T D C O M 6 R C V S H L D 7 R C V C O M 8 R C V 9 D R V S H L D 1 0 D R V C OM 2 R T D S H L D 5 R T D I N 1 2 N C 1 3 N C 4 R T D S E N S E 1 R E S E R V E D 1 5 H T / F F ( - ) 1 6 H T / F F ( + ) 1 4 N C 1 1 D ...

  • Emerson 5081T-FF/FI - page 16

    1 1 6 6 FM B La, Lt OR Lo; OR Lc/Rc (La/Ra OR Lo/Ro) AND Li/Ri (L a/Ra OR Lo /Ro) 1. INSTALLATION SHOULD BE IN ACCORDANC E W ITH ANSI /ISA RP12.06 "INSTALLATION OF INTRIN SICALLY SAFE SYSTEMS FOR H AZARD OUS (C LASSIFIED) LOC ATIONS" (EXCE PT CHAPTER 5 FOR FISCO INSTALLATIONS) AND THE NATIONAL ELECTRICAL CODE (A NSI/NFPA 70) SECTIONS 504 ...

  • Emerson 5081T-FF/FI - page 17

    1 1 7 7 THIS DOCUMENT IS CERTIFIED BY REV REV REV REV REV REV REVISIONS NOT PERMITTED W/O AGENCY APPROVAL DIMENSIONS ARE IN INC HES REMOVE BURRS & SHA RP EDGES .020 MAX MACHINED FILLE T RADII .020 MAX - ITEM PART NO DESCRIPTION QT Y SCALE SIZE REV DW G NO BILL OF M AT ERIAL MATERIAL FINIS H DRAW N CHECKED PROJECT ENGR APVD NOTES: UNLESS OTHERW ...

  • Emerson 5081T-FF/FI - page 18

    1 1 8 8 Rosemount Analytical, Uniloc Divisi on 2400 Barran ca Pkwy Irvine, CA 92 606 UNLESS OTHERWISE SPECIFIED DIMENSIO NS ARE IN INCHES REMOVE BURRS & S HARP EDGES .02 0 MAX MACHINED F ILLET RADII .0 20 MAX FINISH MATERIAL PROJECT ENGR A PVD SIZE DWG NO. REV TITLE SCALE TYPE This document contains information propriet ary to Rosemount Analyti ...

  • Emerson 5081T-FF/FI - page 19

    1 1 9 9 9241514-01/ A DIME NSIONS ARE IN I NCHES REMOVE BURRS & SHA RP EDGES .020 MAX MACHINED FILLE T RADII .020 MA X - ITEM PART NO DESCRIPTION QT Y SCALE SIZE REV DW G NO BILL OF M AT ERIAL MATERIAL FINIS H DRAW N CHECKED PROJECT ENGR APVD NOTES: UNLESS OTHERW ISE SPECIFIED REV ECO NO RELEASE DATE LTR ECO REVISIONS DESCRIPTION BY DATE CHK Th ...

  • Emerson 5081T-FF/FI - page 20

    2 2 0 0 Rosemount Analytical, Uniloc Division 2400 Ba rranca Pk wy Irvine, CA 9 2 606 UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES REMOVE BURRS & SHARP EDGES .020 MAX MACHINED FILLET RADII .020 MAX FINISH MATER IAL PROJECT ENGR APV D SIZE DWG NO. REV TITLE SCALE TYPE This document contains information proprietary to Rosemount Analytical, ...

  • Emerson 5081T-FF/FI - page 21

    2 2 1 1 OVERVIEW This section gives general procedures for routine maintenance of the 5081-T transmitter . The transmitter needs almost no routine maintenance. TRANSMITTER MAINTENANCE Periodically clean the transmitter window with household ammonia or glass cleaner . The detector for the infrared remote controller is located behind the window at th ...

  • Emerson 5081T-FF/FI - page 22

    2 2 2 2 Replacement Part s for Model 5081-T -FF/FI T ransmitter Location in Shipping drawing PN Description Weight 1 23992-07 PCB stack consisting of the CPU (p art 3) and analog (part 4) boards, 1 lb/0.5 kg display board is not included, CPU and analog boards are factory- calibrated as a unit and cannot be ordered separately 2 23638-01 LCD display ...

  • Emerson 5081T-FF/FI - page 23

    2 2 3 3 QUICK-ST ART 1. On the Remote, press PROG , NEXT , ENTER. 2. Use the arrow buttons to select COnduc (conductivity), nAOH (Sodium Hydroxide 0-15%), HCL (Hydrochloric Acid 0-16%), H2SO4L (Sulfuric Acid 0-30%), H2SO4H (Sulfuric Acid 95-99.99%), or CuSt (custom curve) mode. Press ENTER. If you chose CuSt , continue with step 3. If you chose COn ...

  • Emerson 5081T-FF/FI - page 24

    Credit Cards for U.S. Purchases Only . The right people, the right answers, right now . ON-LINE ORDERING NOW A V AILABLE ON OUR WEB SITE http://www .raihome.com Specifications subject to change without notice. Emerson Process Management Liquid Division 2400 Barranca Parkway Irvine, CA 92606 USA T el: (949) 757-8500 Fax: (949) 474-7250 http://www .r ...

Fabricant Emerson Catégorie TV Converter Box

Les documents que nous recevons du fabricant de l'appareilEmerson 5081T-FF/FI peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Emerson
- manuels d’utilisations 5081T-FF/FI
- fiches produit Emerson
- dépliants
- ou étiquettes-énergie Emerson 5081T-FF/FI
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Emerson 5081T-FF/FI.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Emerson 5081T-FF/FI, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Emerson 5081T-FF/FI. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Emerson 5081T-FF/FI.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Emerson 5081T-FF/FI, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Emerson 5081T-FF/FI par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Emerson 5081T-FF/FI.

Le manuel d’utilisation complet Emerson, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Emerson 5081T-FF/FI - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Emerson 5081T-FF/FI, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lEmerson 5081T-FF/FI qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Emerson 5081T-FF/FI - qui devraient nous aider dans les premières étapes lors de l'utilisation Emerson 5081T-FF/FI
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Emerson 5081T-FF/FI
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Emerson 5081T-FF/FI dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Emerson 5081T-FF/FI?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Emerson 5081T-FF/FI, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Emerson 5081T-FF/FI il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)