  • APC BIOM34-EC - page 1

    BIOM34-EC Installation INTRODUCTION APCs’ Biometric Mouse Password Manager (BioM34, Figure 1) enables users to log on to a system or Internet website simply by placing their fingertip on the Biometric Sensor. Use the APC Biometric hardware and software to record and store fingerprint identification for use when accessing password- protected syste ...

  • APC BIOM34-EC - page 2

    E. Once you have accepted the terms of the License Agreement the Choose Location Destination screen is displayed (Figure 7). Figure 7. Choose Destination Location Screen For most users, the destination location identified by the software is sufficient. If this is the case, click the Next button. Advanced users may want to select an alternate locati ...

  • APC BIOM34-EC - page 3

    B. The software will then display the Blank Capture Fingerprint screen (Figure 17). Place the choosen finger over the Sensor and Drive Ring (Figure 18). Figure 16. Selected Finger Screen Figure 17. Blank Capture Fingerprint Screen Note: Place the finger on the BioM34 sensor and drive ring (Figure 18) for scanning. Use light, but firm and steady pre ...

  • APC BIOM34-EC - page 4

    A. Click on the circle next to the desired selection, then click on Next, Cancel, or Start Over. B. Once the settings have been chosen, select Next and the Congratulations screen (Figure 24) will be displayed. Click Done to complete the enrollment process; the Logon New User screen (Figure 25) is displayed. Click Y es to logon the new user, or clic ...

  • APC BIOM34-EC - page 5

    LOGGING ON WITH THE BIOMETRIC HARDWARE Each time a user logs on with the BioM34 installed, a fingerprint window is displayed with the Logon User Authentication screen (Figure 11). Simply place the correct finger on the Biometric Sensor and Drive Ring. If authentication is successful, the fingerprint will turn green. If authentication is not success ...

  • APC BIOM34-EC - page 6

    Biometric Password Managers M.8 BIOPOD Installation INTRODUCTION The APC Biopod (Figure 1) enables users to log on to a system simply by placing their fingertip on the Biopod sensor. Use the Biopod hardware and software to provide fingerprint identification to access passwordprotected systems, applications, and web sites, without password authoriza ...

  • APC BIOM34-EC - page 7

    Biometric Password Managers M.9 Keep the finger on the sensor and hold it down until the flashing green box below the fingerprint display is a solid green. Lift the finger and replace it on the sensor. Repeat this procedure until a message appears indicating that the enrollment process is complete. For improved performance, place the finger in slig ...

  • APC BIOM34-EC - page 8

    Biometric Password Managers M.10 WINDOWS 98/ME CONFIGURATION In Windows 98/ME, APC OmniPass replaces the login screen to make the operating system more secure. To take advantage of this feature, do the following: 1 . From the Windows Start menu, select Start> Settings> Control Panel. 2 . Select the APC OmniPass control panel. 3 . Select the E ...

  • APC BIOM34-EC - page 9

    BIOPOD & BIOM34-EC - User Manual Softex OmniPass provides password management capabilities to Microsoft Windows operating systems. OmniPass enables you to use a "master password" for all Windows, application and on-line passwords. A "master password" is an OmniPass authentication method which simplifies all your authenticati ...

  • APC BIOM34-EC - page 10

    NOTE: For installation on Windows 2000, Windows XP, or Windows 2003, OmniPass requires that the user installing OmniPass have administrative privileges to the system. If your current user does not have administrative privileges, log out and then log in with an administrator user before proceeding with OmniPass installation. To install OmniPass on y ...

  • APC BIOM34-EC - page 11

    is assuming he is accessing those sites with the system he enrolled his OmniPass user onto. OmniPass does not actually change the credentials of the password protected resource. If he were to go to an Internet café to access his webmail, he would need to enter his original webmail credentials ("Ikari" and "warriors") to gain ac ...

  • APC BIOM34-EC - page 12

    Swipe sensors are a type of fingerprint sensor that are operated by placing your finger on the scanner and pulling the finger across the sensor firmly with even speed. Swiping too fast or too slow will result in a failed fingerprint capture. For better results, it is recommended that you use the practice fingerprint selection before enrolling the f ...

  • APC BIOM34-EC - page 13

    WARNING: Depending upon how the SmartCard was initially configured, a limited number of failed PIN attempts may be enforced. If this is the case, and you exceed the maximum failed PIN attempts, the card may become locked and permanently unusable. To find out more, contact whoever configured your SmartCard for you, or the SmartCard manufacturer If y ...

  • APC BIOM34-EC - page 14

    WARNING: This setting is more convenient in that whenever you go to a site remembered with this setting, you will bypass any authentication procedure and gain instant access to the site. But should you leave your system unattended, unlocked, with your OmniPass user logged in, anyone using your system can browse to your password protected sites and ...

  • APC BIOM34-EC - page 15

    3.6.2 Switch User Identity -- To switch identities at any time, right-click the OmniPass system tray icon and click Switch User Identity from the submenu. The Switch Identity dialog will appear. Select the desired identity and then click OK . 3.7 Identities and Password Management On the Manage Passwords interface of the Vault Management tab of the ...

  • APC BIOM34-EC - page 16

    This .opi file contains all your user specific OmniPass data, and it is both encrypted and password protected. This user profile does NOT contain any of your encrypted data files. 5.2 Importing an OmniPass User Profile NOTE: You cannot import a user into OmniPass if there already is a user with the same name enrolled in OmniPass. To import an OmniP ...

  • APC BIOM34-EC - page 17

    click Enroll Authentication Device , and authenticate with OmniPass. Select the fingerprint recognition device in the Select Authentication Device screen (it should already be marked by a green check if you have a finger enrolled) and click Next . The rest of the procedure to enroll an additional finger can be found starting with Chapter 2.3.2. If ...

  • APC BIOM34-EC - page 18

    Appendix A: Troubleshooting Most major problems can be avoided by paying special attention to the NOTES and WARNINGS distributed throughout this document. Other common problems are discussed in this appendix. For support not covered in this document contact support@softexinc.com. Windows 2000/Windows XP Issues In Windows 2000 or Windows XP, you can ...

Fabbricante APC Categoria Mouse

I documenti che otteniamo dal fabbricante del dispositivoAPC BIOM34-EC possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici APC
- manuali per l’uso BIOM34-EC
- schede prodotto APC
- opuscoli
- o etichette energetiche APC BIOM34-EC
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso APC BIOM34-EC.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione APC BIOM34-EC, manuali di manutenzione, brevi manuali o manuali utente APC BIOM34-EC. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto APC BIOM34-EC.

Manuali per l’uso simili

Manuale completo del dispositivo APC BIOM34-EC, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare APC BIOM34-EC dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti APC BIOM34-EC.

Il manuale per l’uso completo APC, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale APC BIOM34-EC - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice APC BIOM34-EC, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per APC BIOM34-EC che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo APC BIOM34-EC - che ci dovrebbe aiutare nei primi passi durante l'uso APC BIOM34-EC
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del APC BIOM34-EC
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio APC BIOM34-EC in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su APC BIOM34-EC?

Utilizza il modulo sottostante

Se non hai risolto il problema con APC BIOM34-EC con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con APC BIOM34-EC è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)