    DLM 600W Series P o w er Supplies M51A Option: Isolated Analog Programming Manual Power Supplies Elgar Electronics Corporation 9250 Brown Deer Road San Diego, CA 92121-2294 1-800-73ELGAR (1-800-733-5427) Tel: (858) 450-0085 Fax: (858) 458-0267 Email: sales@elgar.com www.el gar .co m ©2002 by Elgar Electronics Corporation This document contains inf ...

  • Furuno M51A - page 2

    . ...

  • Furuno M51A - page 3

    SAFETY NOTICE Before applying power to the system, verify that t he instrument is configured properly for the user’s particular application. WARNING! Hazardous voltages may be present when covers are removed. Qualified personnel must use extreme caution when servicing this equipment. Circuit boards, test points, and output voltages also may be fl ...

  • Furuno M51A - page 4

    SAFETY SYMBOLS ii ...

  • Furuno M51A - page 5

    ELGAR FIVE–YEAR WARRANTY Elgar Electronics Corporation (hereinafter referred to as Elgar) warrants its products to be free from defects in material and workmanship. This warranty is effective for one year from the date of shipment of the product to the original purchaser. Liability of Elgar under this warranty shall exist provided that: • the B ...

  • Furuno M51A - page 6

    This page intentionally left blank. iv ...

  • Furuno M51A - page 7

    CONTENTS SECTION 1 M51A OPTION OVERVIEW 1.1 Introduction ...................................................................................................... 1-1 1.2 General Description ......................................................................................... 1-1 1.3 Specifications.................................................. ...

  • Furuno M51A - page 8

    Contents DLM 600W Series LIST OF TABLES Table 2–1. INTFC SETUP Switch ............................................................................... 2-1 Table 2–2. ISOLATED ANALOG INTERFACE Connector Pinout .............................. 2-4 Table 2–3. Remote Programming Configuration Options ........................................... 2-7 T ...

  • Furuno M51A - page 9

    SECTION 1 1.1 Introduction 1.2 M51A OPTION OVERVIEW This addendum is to be used in conjunction with the DLM 600W Series Power Supplies Operation Manual, Sorensen Document No. M362161-01. The Sorensen M51A Option for the DLM 600W Series power supplies provides a remote analog interface, which has safety isolation from the output terminals. This allo ...

  • Furuno M51A - page 10

    M51A Option Overview DLM 600W Series 1.3 Specifications 1.3.1 1.3.2 Electrical Specifications Remote Voltage Programming Accuracy, 0-5/10V Inputs: Output Voltage: 0.5% of Vmax Output Current: 0.75% of Imax OVP: 1.0% of 1.1 X Vmax Remote 4-20mA Programming Accuracy: Output Voltage: 0.75% of Vmax Output Current: 1.0% of Imax Supplemental Characterist ...

  • Furuno M51A - page 11

    SECTION 2 2.1 ISOLATED REMOTE ANALOG INTERFACE OPERATION INTFC SETUP Switch The INTFC SETUP (Interface Setup) switch is accessible from the rear panel of the unit. It provides user selectability of the programming/monitoring ranges and signal types, as well as configuring the power supply for operation under remote control. Setting a switch to the ...

  • Furuno M51A - page 12

    Isolated Remote Analog Interface Operation DLM 600W Series 2-2 M51A Option 2.1.1 2.2 INTFC SETUP Switch Functions The following sections describe the functions of the various switch positions: V, 10V or 4-20mA Select: Position-1, when ON, selects 0-10VDC programming of the output voltage. Also, must be set to ON position when the ISOLATED ANALOG IN ...

  • Furuno M51A - page 13

    DLM 600W Series Isolated Remote Analog Interface Operation M51A Option 2-3 Figure 2–1. Rear Panel View, Low–Voltage Models Figure 2–2. Rear Panel View, High–Voltage Models ...

  • Furuno M51A - page 14

    Isolated Remote Analog Interface Operation DLM 600W Series 2-4 M51A Option 2.3 Isolated Analog Interface Connector The ISOLATED ANALOG INTERFACE connector is a 25-position female Subminiature-D type. Pin Function 1 ANALOG-CONTROL input 2 Return for 0-5/10V monitor outputs and EXTERNAL-OFF 3 OVP programming input 4 Voltage monitor output, 4-20mA 5 V ...

  • Furuno M51A - page 15

    DLM 600W Series Isolated Remote Analog Interface Operation M51A Option 2-5 2.3.1 ISOLATED ANALOG INTERFACE Functions The following sections describe the functions of the various signals of the ISOLATED ANALOG INTERFACE. Pin numbers correspond to the connector pinout of Table 2–2. Digital Control Input Signals ANALOG-CONTROL: Pin-1, enables remote ...

  • Furuno M51A - page 16

    Isolated Remote Analog Interface Operation DLM 600W Series 2-6 M51A Option Analog Programming Signals OVP PROGRAMMING INPUT: Pin-3, an input signal of 0-5 volts or 0-10 volts (user selectable with INTFC SETUP switch) programs the OVP threshold from 5-110% of full scale output voltage. Signal is referenced to Pin-12. Circui t is SELV, and has electr ...

  • Furuno M51A - page 17

    DLM 600W Series Isolated Remote Analog Interface Operation M51A Option 2-7 CURRENT RESISTANCE PROGRAMMING OUTPUT: Pin-22 provides a 1mA current source which would be connected to Pin-10, CURRENT PROGRAMMING INPUT, with a 0-5k Ω external resistor connected between Pin-22 to Pin-12, to program the output current from 0-100% of full scale output. Th ...

  • Furuno M51A - page 18

    Isolated Remote Analog Interface Operation DLM 600W Series 2-8 M51A Option 2.4.1 2.4.2 2.4.3 Voltage Source Progra mming of Output Voltage Setting up for voltage source programming of the output voltage is as follows: 1. Set Position-1, V, of the INTFC SETUP switch to OFF (down) for 0-5VDC programming range. 2. Set Position-1, V, of the INTFC SETUP ...

  • Furuno M51A - page 19

    DLM 600W Series Isolated Remote Analog Interface Operation M51A Option 2-9 4. Program the other parameters to the desired limit values: VOLTAGE PROGRAMMING INPUT, Pin-9, and the CURRENT PROGRAMMING INPUT, Pin-10, with respect to Pin-12. 5. Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG INTERFACE connector to Pin-15. 2.4.4 2.4.5 Resistance Pr ...

  • Furuno M51A - page 20

    Isolated Remote Analog Interface Operation DLM 600W Series 2-10 M51A Option 2.4.6 2.4.7 2.4.8 Resistance Programming of OVP Setting up for resistance programming OVP is as follows: 1. Set Position-3, OVP, of the INTFC SETUP switch to OFF (down) for 0-5VDC programming range. 2. Connect the external programming resistance, 0-5k Ω , to the ISOLATED ...

  • Furuno M51A - page 21

    DLM 600W Series Isolated Remote Analog Interface Operation M51A Option 2-11 3. Connect a jumper from Pin-13 to Pin-12. 4. Connect a jumper from Pin-11 to Pin-23. 5. Program the other parameters to the desired limit values: VOLTAGE PROGRAMMING INPUT, Pin-9, and the OVP PROGRAMMING INPUT, Pin-3, with respect to pin-12. 6. Connect Pin-1, ANALOG-CONTRO ...

  • Furuno M51A - page 22

    Isolated Remote Analog Interface Operation DLM 600W Series 2-12 M51A Option 2.7 Remote Digital Status Signals Digital signals are available for remote monitoring the operational status of the unit. Refer to Table 2–5 for information on the characteristics of the signals. ISOLATED ANALOG INTERFACE Connections Logic Levels (with No Signal Output Cu ...

Fabbricante Furuno Categoria Power Supply

I documenti che otteniamo dal fabbricante del dispositivoFuruno M51A possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Furuno
- manuali per l’uso M51A
- schede prodotto Furuno
- opuscoli
- o etichette energetiche Furuno M51A
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Furuno M51A.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Furuno M51A, manuali di manutenzione, brevi manuali o manuali utente Furuno M51A. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Furuno M51A.

Manuali per l’uso simili

Manuale completo del dispositivo Furuno M51A, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Furuno M51A dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Furuno M51A.

Il manuale per l’uso completo Furuno, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Furuno M51A - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Furuno M51A, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Furuno M51A che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Furuno M51A - che ci dovrebbe aiutare nei primi passi durante l'uso Furuno M51A
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Furuno M51A
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Furuno M51A in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Furuno M51A?

Utilizza il modulo sottostante

Se non hai risolto il problema con Furuno M51A con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Furuno M51A è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)