Furuno M51Aの取扱説明書

22ページ 0.39 mb
ダウンロード

ページに移動 of 22

Summary
  • Furuno M51A - page 1

    DLM 600W Series P o w er Supplies M51A Option: Isolated Analog Programming Manual Power Supplies Elgar Electronics Corporation 9250 Brown Deer Road San Diego, CA 92121-2294 1-800-73ELGAR (1-800-733-5427) Tel: (858) 450-0085 Fax: (858) 458-0267 Email: sales@elgar.com www.el gar .co m ©2002 by Elgar Electronics Corporation This document contains inf ...

  • Furuno M51A - page 2

    . ...

  • Furuno M51A - page 3

    SAFETY NOTICE Before applying power to the system, verify that t he instrument is configured properly for the user’s particular application. WARNING! Hazardous voltages may be present when covers are removed. Qualified personnel must use extreme caution when servicing this equipment. Circuit boards, test points, and output voltages also may be fl ...

  • Furuno M51A - page 4

    SAFETY SYMBOLS ii ...

  • Furuno M51A - page 5

    ELGAR FIVE–YEAR WARRANTY Elgar Electronics Corporation (hereinafter referred to as Elgar) warrants its products to be free from defects in material and workmanship. This warranty is effective for one year from the date of shipment of the product to the original purchaser. Liability of Elgar under this warranty shall exist provided that: • the B ...

  • Furuno M51A - page 6

    This page intentionally left blank. iv ...

  • Furuno M51A - page 7

    CONTENTS SECTION 1 M51A OPTION OVERVIEW 1.1 Introduction ...................................................................................................... 1-1 1.2 General Description ......................................................................................... 1-1 1.3 Specifications.................................................. ...

  • Furuno M51A - page 8

    Contents DLM 600W Series LIST OF TABLES Table 2–1. INTFC SETUP Switch ............................................................................... 2-1 Table 2–2. ISOLATED ANALOG INTERFACE Connector Pinout .............................. 2-4 Table 2–3. Remote Programming Configuration Options ........................................... 2-7 T ...

  • Furuno M51A - page 9

    SECTION 1 1.1 Introduction 1.2 M51A OPTION OVERVIEW This addendum is to be used in conjunction with the DLM 600W Series Power Supplies Operation Manual, Sorensen Document No. M362161-01. The Sorensen M51A Option for the DLM 600W Series power supplies provides a remote analog interface, which has safety isolation from the output terminals. This allo ...

  • Furuno M51A - page 10

    M51A Option Overview DLM 600W Series 1.3 Specifications 1.3.1 1.3.2 Electrical Specifications Remote Voltage Programming Accuracy, 0-5/10V Inputs: Output Voltage: 0.5% of Vmax Output Current: 0.75% of Imax OVP: 1.0% of 1.1 X Vmax Remote 4-20mA Programming Accuracy: Output Voltage: 0.75% of Vmax Output Current: 1.0% of Imax Supplemental Characterist ...

  • Furuno M51A - page 11

    SECTION 2 2.1 ISOLATED REMOTE ANALOG INTERFACE OPERATION INTFC SETUP Switch The INTFC SETUP (Interface Setup) switch is accessible from the rear panel of the unit. It provides user selectability of the programming/monitoring ranges and signal types, as well as configuring the power supply for operation under remote control. Setting a switch to the ...

  • Furuno M51A - page 12

    Isolated Remote Analog Interface Operation DLM 600W Series 2-2 M51A Option 2.1.1 2.2 INTFC SETUP Switch Functions The following sections describe the functions of the various switch positions: V, 10V or 4-20mA Select: Position-1, when ON, selects 0-10VDC programming of the output voltage. Also, must be set to ON position when the ISOLATED ANALOG IN ...

  • Furuno M51A - page 13

    DLM 600W Series Isolated Remote Analog Interface Operation M51A Option 2-3 Figure 2–1. Rear Panel View, Low–Voltage Models Figure 2–2. Rear Panel View, High–Voltage Models ...

  • Furuno M51A - page 14

    Isolated Remote Analog Interface Operation DLM 600W Series 2-4 M51A Option 2.3 Isolated Analog Interface Connector The ISOLATED ANALOG INTERFACE connector is a 25-position female Subminiature-D type. Pin Function 1 ANALOG-CONTROL input 2 Return for 0-5/10V monitor outputs and EXTERNAL-OFF 3 OVP programming input 4 Voltage monitor output, 4-20mA 5 V ...

  • Furuno M51A - page 15

    DLM 600W Series Isolated Remote Analog Interface Operation M51A Option 2-5 2.3.1 ISOLATED ANALOG INTERFACE Functions The following sections describe the functions of the various signals of the ISOLATED ANALOG INTERFACE. Pin numbers correspond to the connector pinout of Table 2–2. Digital Control Input Signals ANALOG-CONTROL: Pin-1, enables remote ...

  • Furuno M51A - page 16

    Isolated Remote Analog Interface Operation DLM 600W Series 2-6 M51A Option Analog Programming Signals OVP PROGRAMMING INPUT: Pin-3, an input signal of 0-5 volts or 0-10 volts (user selectable with INTFC SETUP switch) programs the OVP threshold from 5-110% of full scale output voltage. Signal is referenced to Pin-12. Circui t is SELV, and has electr ...

  • Furuno M51A - page 17

    DLM 600W Series Isolated Remote Analog Interface Operation M51A Option 2-7 CURRENT RESISTANCE PROGRAMMING OUTPUT: Pin-22 provides a 1mA current source which would be connected to Pin-10, CURRENT PROGRAMMING INPUT, with a 0-5k Ω external resistor connected between Pin-22 to Pin-12, to program the output current from 0-100% of full scale output. Th ...

  • Furuno M51A - page 18

    Isolated Remote Analog Interface Operation DLM 600W Series 2-8 M51A Option 2.4.1 2.4.2 2.4.3 Voltage Source Progra mming of Output Voltage Setting up for voltage source programming of the output voltage is as follows: 1. Set Position-1, V, of the INTFC SETUP switch to OFF (down) for 0-5VDC programming range. 2. Set Position-1, V, of the INTFC SETUP ...

  • Furuno M51A - page 19

    DLM 600W Series Isolated Remote Analog Interface Operation M51A Option 2-9 4. Program the other parameters to the desired limit values: VOLTAGE PROGRAMMING INPUT, Pin-9, and the CURRENT PROGRAMMING INPUT, Pin-10, with respect to Pin-12. 5. Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG INTERFACE connector to Pin-15. 2.4.4 2.4.5 Resistance Pr ...

  • Furuno M51A - page 20

    Isolated Remote Analog Interface Operation DLM 600W Series 2-10 M51A Option 2.4.6 2.4.7 2.4.8 Resistance Programming of OVP Setting up for resistance programming OVP is as follows: 1. Set Position-3, OVP, of the INTFC SETUP switch to OFF (down) for 0-5VDC programming range. 2. Connect the external programming resistance, 0-5k Ω , to the ISOLATED ...

  • Furuno M51A - page 21

    DLM 600W Series Isolated Remote Analog Interface Operation M51A Option 2-11 3. Connect a jumper from Pin-13 to Pin-12. 4. Connect a jumper from Pin-11 to Pin-23. 5. Program the other parameters to the desired limit values: VOLTAGE PROGRAMMING INPUT, Pin-9, and the OVP PROGRAMMING INPUT, Pin-3, with respect to pin-12. 6. Connect Pin-1, ANALOG-CONTRO ...

  • Furuno M51A - page 22

    Isolated Remote Analog Interface Operation DLM 600W Series 2-12 M51A Option 2.7 Remote Digital Status Signals Digital signals are available for remote monitoring the operational status of the unit. Refer to Table 2–5 for information on the characteristics of the signals. ISOLATED ANALOG INTERFACE Connections Logic Levels (with No Signal Output Cu ...

メーカー Furuno カテゴリー Power Supply

Furuno M51Aのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- M51Aの取扱説明書
- Furunoの製品カード
- パンフレット
- またはFuruno M51Aの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Furuno M51Aの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Furuno M51Aの取り付け説明書、サービスマニュアル、簡易説明書、またはFuruno M51Aのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Furuno M51Aの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Furuno M51Aデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがFuruno M51Aを使用するのを助ける技術的文書のことです。説明書は通常、全てのFuruno M51Aユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Furunoの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Furuno M51Aの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははFuruno M51Aの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Furuno M51Aに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Furuno M51Aデバイスの基本機能を使うにあたってのヒント。 Furuno M51Aのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Furuno M51Aに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるFuruno M51Aのメーカー/サービスへの連絡先に関する情報。

Furuno M51Aについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもFuruno M51Aの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがFuruno M51Aで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)