  • Cornelius CH951 - page 1

    Operator ’ s Manual CHILLER (“CH” SERIES) Models: CH750, CH751, and CH951 PRINTED IN U.S.A IMI CORNELIUS INC; 2002  IMI CORNELIUS REMCOR INC  500 REGENCY DRIVE  GLENDALE HEIGHTS, IL 60139–2268 T elephone (800) 551–4423 Facsimile (800) 519–4423 Part No. 91256 Revision Date: August 9, 2002 Revision: C THIS DOCUMENT CONT AINS IMPO ...

  • Cornelius CH951 - page 2

    T ABLE OF CONTENTS INST ALLA TION INSTRUCTIONS 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . Location 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Plumbing 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Cornelius CH951 - page 3

    1 91256 INTRODUCTION The REMCOR “ CH ” Series W ater Chillers (Models CH750 – A, CH751 – A, and CH951 – A) are specifically de- signed to cool clean liquid before it is circulated to the cooling application. The Unit includes a complete refrig- eration system and associated controls housed in a sturdy sheet metal enclosure with perforated ...

  • Cornelius CH951 - page 4

    2 91256 INST ALLA TION INSTRUCTIONS LOCA TION Locate the chiller indoors in a well ventilated area with ambient temperatures in the range of 65 ° F to 100 ° F. Allow a minimum of six inches of clearance around the chiller for proper air circulation. Avoid hot air discharge from other equipment or enclosed areas where heat could build up and cause ...

  • Cornelius CH951 - page 5

    3 91256 Once these start – up procedures are complete, the chiller is ready for standard operation. NOTE: 1) Never operate the chiller with enclosure panels removed. 2) Always use the illuminated switch to turn off the chiller when it is not being used. 3) Always ensure that all air inlets and outlets are free of obstructions. MAINTENANCE W ARNIN ...

  • Cornelius CH951 - page 6

    4 91256 5. Install the new thermostat in the front panel and secure it with the mounting bracket. 6. Reconnect the wires at back of the thermostat. 7. Install the wrapper . REPLACING ELECTRONIC DIFFERENTIAL THERMOST A T 1. Remove the wrapper as specified in REMOVING WRAPPER. 2. Remove the two screws securing the thermostat cover and remove the cove ...

  • Cornelius CH951 - page 7

    5 91256 FLUID RECOMMENDA TION Remcor Chillers are designed to operate with water to provide maximum performance for temperatures of 40  F – 100  F. Distilled W ater Acceptable De – Ionized W ater (1 – 5 MEG/OHMS) Acceptable De – Ionized W ater (5+MEG/OHMS) Acceptable with Stainless Steel & PVC only *No Copper or Brass Propylene Gl ...

  • Cornelius CH951 - page 8

    6 91272 TROUBLESHOOTING GUIDE T rouble Probable Cause Remedy CHILLER DOES NOT OPERA TE A. No power . A. Check fuse or circuit breaker . B. Loose or poor wire connection. B. Check wiring. Correct for loose or poor wire connection. C. Inoperable ON – OFF switch. C. Replace ON – OFF switch. D. Overload device open. D. Allow compressor to cool, the ...

  • Cornelius CH951 - page 9

    7 620909701 P ARTS LIST FIGURE 1. CH750, CH751 AND CH951 EXPLODED VIEW Item No. Part No. Name 1 31934 Switch, Illuminated 31935 Switch, Illuminated 2 32386 Thermostat, Eliwell No. EWPC902 3 620603708 Blade, Fan 4 62060371 1 Motor , Fan (CH550) 620603712 Motor , Fan (CH750) 620603713 Motor , Fan (CH551) 5 * Condenser 6 Not Used 7 620603701 Compresso ...

  • Cornelius CH951 - page 10

    ...

  • Cornelius CH951 - page 11

    8 91272 W ARRANTY IMI Cornelius Inc. warrants that all equipment and parts are free from defects in material and workmanship un- der normal use and service. For a copy of the warranty applicable to your Cornelius, Remcor or W ilshire prod- uct, in your country , please write, fax or telephone the IMI Cornelius office nearest you. Please provide the ...

  • Cornelius CH951 - page 12

    CORPORA TE HEADQUARTERS: Remcor Incorporated 500 Regency Drive Glendale Heights, IL 60139 ...

Fabbricante Cornelius Categoria Refrigerator

I documenti che otteniamo dal fabbricante del dispositivoCornelius CH951 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Cornelius
- manuali per l’uso CH951
- schede prodotto Cornelius
- opuscoli
- o etichette energetiche Cornelius CH951
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Cornelius CH951.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Cornelius CH951, manuali di manutenzione, brevi manuali o manuali utente Cornelius CH951. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Cornelius CH951.

Manuali per l’uso simili

Manuale completo del dispositivo Cornelius CH951, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Cornelius CH951 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Cornelius CH951.

Il manuale per l’uso completo Cornelius, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Cornelius CH951 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Cornelius CH951, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Cornelius CH951 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Cornelius CH951 - che ci dovrebbe aiutare nei primi passi durante l'uso Cornelius CH951
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Cornelius CH951
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Cornelius CH951 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Cornelius CH951?

Utilizza il modulo sottostante

Se non hai risolto il problema con Cornelius CH951 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Cornelius CH951 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)