  • Cornelius CH951 - page 1

    Operator ’ s Manual CHILLER (“CH” SERIES) Models: CH750, CH751, and CH951 PRINTED IN U.S.A IMI CORNELIUS INC; 2002  IMI CORNELIUS REMCOR INC  500 REGENCY DRIVE  GLENDALE HEIGHTS, IL 60139–2268 T elephone (800) 551–4423 Facsimile (800) 519–4423 Part No. 91256 Revision Date: August 9, 2002 Revision: C THIS DOCUMENT CONT AINS IMPO ...

  • Cornelius CH951 - page 2

    T ABLE OF CONTENTS INST ALLA TION INSTRUCTIONS 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . Location 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Plumbing 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Cornelius CH951 - page 3

    1 91256 INTRODUCTION The REMCOR “ CH ” Series W ater Chillers (Models CH750 – A, CH751 – A, and CH951 – A) are specifically de- signed to cool clean liquid before it is circulated to the cooling application. The Unit includes a complete refrig- eration system and associated controls housed in a sturdy sheet metal enclosure with perforated ...

  • Cornelius CH951 - page 4

    2 91256 INST ALLA TION INSTRUCTIONS LOCA TION Locate the chiller indoors in a well ventilated area with ambient temperatures in the range of 65 ° F to 100 ° F. Allow a minimum of six inches of clearance around the chiller for proper air circulation. Avoid hot air discharge from other equipment or enclosed areas where heat could build up and cause ...

  • Cornelius CH951 - page 5

    3 91256 Once these start – up procedures are complete, the chiller is ready for standard operation. NOTE: 1) Never operate the chiller with enclosure panels removed. 2) Always use the illuminated switch to turn off the chiller when it is not being used. 3) Always ensure that all air inlets and outlets are free of obstructions. MAINTENANCE W ARNIN ...

  • Cornelius CH951 - page 6

    4 91256 5. Install the new thermostat in the front panel and secure it with the mounting bracket. 6. Reconnect the wires at back of the thermostat. 7. Install the wrapper . REPLACING ELECTRONIC DIFFERENTIAL THERMOST A T 1. Remove the wrapper as specified in REMOVING WRAPPER. 2. Remove the two screws securing the thermostat cover and remove the cove ...

  • Cornelius CH951 - page 7

    5 91256 FLUID RECOMMENDA TION Remcor Chillers are designed to operate with water to provide maximum performance for temperatures of 40  F – 100  F. Distilled W ater Acceptable De – Ionized W ater (1 – 5 MEG/OHMS) Acceptable De – Ionized W ater (5+MEG/OHMS) Acceptable with Stainless Steel & PVC only *No Copper or Brass Propylene Gl ...

  • Cornelius CH951 - page 8

    6 91272 TROUBLESHOOTING GUIDE T rouble Probable Cause Remedy CHILLER DOES NOT OPERA TE A. No power . A. Check fuse or circuit breaker . B. Loose or poor wire connection. B. Check wiring. Correct for loose or poor wire connection. C. Inoperable ON – OFF switch. C. Replace ON – OFF switch. D. Overload device open. D. Allow compressor to cool, the ...

  • Cornelius CH951 - page 9

    7 620909701 P ARTS LIST FIGURE 1. CH750, CH751 AND CH951 EXPLODED VIEW Item No. Part No. Name 1 31934 Switch, Illuminated 31935 Switch, Illuminated 2 32386 Thermostat, Eliwell No. EWPC902 3 620603708 Blade, Fan 4 62060371 1 Motor , Fan (CH550) 620603712 Motor , Fan (CH750) 620603713 Motor , Fan (CH551) 5 * Condenser 6 Not Used 7 620603701 Compresso ...

  • Cornelius CH951 - page 10

    ...

  • Cornelius CH951 - page 11

    8 91272 W ARRANTY IMI Cornelius Inc. warrants that all equipment and parts are free from defects in material and workmanship un- der normal use and service. For a copy of the warranty applicable to your Cornelius, Remcor or W ilshire prod- uct, in your country , please write, fax or telephone the IMI Cornelius office nearest you. Please provide the ...

  • Cornelius CH951 - page 12

    CORPORA TE HEADQUARTERS: Remcor Incorporated 500 Regency Drive Glendale Heights, IL 60139 ...

メーカー Cornelius カテゴリー Refrigerator

Cornelius CH951のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- CH951の取扱説明書
- Corneliusの製品カード
- パンフレット
- またはCornelius CH951の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Cornelius CH951の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Cornelius CH951の取り付け説明書、サービスマニュアル、簡易説明書、またはCornelius CH951のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Cornelius CH951の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Cornelius CH951デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがCornelius CH951を使用するのを助ける技術的文書のことです。説明書は通常、全てのCornelius CH951ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Corneliusの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Cornelius CH951の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははCornelius CH951の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Cornelius CH951に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Cornelius CH951デバイスの基本機能を使うにあたってのヒント。 Cornelius CH951のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Cornelius CH951に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるCornelius CH951のメーカー/サービスへの連絡先に関する情報。

Cornelius CH951についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもCornelius CH951の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがCornelius CH951で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)