Manuale per l’uso Datalogic DS6500

36 pagine 4.03 mb
Scarica

Vai alla pagina of 36

Summary
  • Datalogic DS6500 - page 1

    DS6500 INSTA LLA TION QUICK REFERENCE ...

  • Datalogic DS6500 - page 2

    CONTENTS DS6500-100-010 M ASTER/SLAVE MODEL ........................................................................................................... 1 DS6500-100-011 PROFIBUS MODEL ..................................................................................................................... 8 DS6500-100-012 ET HERNET MODEL ............... ...

  • Datalogic DS6500 - page 3

    DS6500 MASTER/SLAVE MODEL DS6500-100-010 MASTER/SLAVE MODEL Figure A Laser Beam Output W indow 1 Figure B Programming Keyp ad 1 Phase On LED (Yellow) 3 TX Data LED (Gree n) 2 Pow er On L ED (Re d) 4 LCD Display 5 Figure C Main/Aux. I nterf ace 25 -pin D-su b Male Connector 1 Lonworks 9-pin Male Connecto r 2 Lonworks 9-pi n Female Con nector 3 2 3 4 ...

  • Datalogic DS6500 - page 4

    DS6500 MASTER/SLAVE MODEL SOFTWA RE FEA TURES ENVIRONMENTA L FEA TURES Interleaved 2/5 Readable Codes Code 39 standard Operating Temperature 0° to +40 °C (+32 to +104 °F) Codabar Code 128 Storage Temperature -20° to +70 °C (-4° to +158 °F) EAN 128 Humidity 90% non condensing Code 93 (Standard & Full ASCII) A mbient Light EAN/UPC (includi ...

  • Datalogic DS6500 - page 5

    DS6500 MASTER/SLAVE MODEL The details of the connector pins ar e indicated in the following table: 25-pin D-Sub Connector Pinout Pin Name Function Chassis - internally connected to GND 1 CHASSIS Cable shield connected to chassis 20 RX AU X Receive data of auxiliary RS232 (referred to GND) 21 TXAU X Transmit data of auxiliary RS232 (referred to GND) ...

  • Datalogic DS6500 - page 6

    DS6500 MASTER/SLAVE MODEL Connectivity: Point-to-Point Layout DS6500 CAB-600X C-BOX 100 Local Host *P.S. PG6000 * P.S. (Presence Sensor) connect ed to External Trigger/PS input. Pass Through Layout E N T < < E N T < < *P.S. *P.S. Gryphon DS4600A DS4600A DS6500 CAB-600X C-BOX 100 C-BOX 100 C-BOX 100 A U X MAIN *P.S. 2 2 1 1 Local Host 1 ...

  • Datalogic DS6500 - page 7

    DS6500 MASTER/SLAVE MODEL Multiplexer Layout E N T < < E N T < < *P.S. *P.S. DS4600A DS4600A DS6500 PWR-120 CAB-600X C-BOX 100 C-BOX 100 C-BOX 100 MX4000 #0 1 #31 #1 Local Host 1 RS485 HD M ain Interface * P.S. (Presence Sensor) connect ed to External Trigger/PS input. RS232 Master/Slave Lay out E N T < < E N T < < DS6500 Ma ...

  • Datalogic DS6500 - page 8

    DS6500 MASTER/SLAVE MODEL Local Lonworks Netw ork CAB-60XX CAB-610X BTK-6000 C-BOX 100** Master Encoder*** BTK-6000 Slave 1 *P.S. Local Host CAB-63XX PWR-120 Small Synchronized Network w ith 2 Readers * P.S. (Presence Sensor) connect ed to External Trigger/PS input. ** C-BOX 100 modified to accept scanner power. *** Encoder connected to IN2/ENC inp ...

  • Datalogic DS6500 - page 9

    DS6500 MASTER/SLAVE MODEL Large Synchronized Ne tw ork ** * * P.S. (Presence Sensor) connect ed to External Trigger/PS input. ** Encoder connected to IN2/ENC input. Large Synchronized Network wi th DX6X00 and DS6XXX Scanners . 7 ...

  • Datalogic DS6500 - page 10

    DS6500 PROFIBUS MODEL DS6500-100-011 PROFIBUS MODEL Figure A Laser Beam Output W indow 1 Figure B Programming Keyp ad 1 Phase On LED (Yellow) 3 TX Data LED (Gree n) 2 Pow er On L ED (Re d) 4 LCD Display 5 Figure C Prof ibus 9- pin Female Connector (whit e) 1 Lonworks 9-pin Female Con nector 2 Ma in/Aux. Interface 2 6-pin D -Sub M ale Co nnector 3 1 ...

  • Datalogic DS6500 - page 11

    DS6500 PROFIBUS MODEL SOFTWA RE FEA TURES ENVIRONMENTA L FEA TURES Interleaved 2/5 Readable Codes Code 39 standard Operating Temperature 0° to +40 °C (+32 to +104 °F) Codabar Code 128 Storage Temperature -20° to +70 °C (-4° to +158 °F) EAN 128 Humidity 90% non condensing Code 93 (Standard & Full ASCII) A mbient Light EAN/UPC (including A ...

  • Datalogic DS6500 - page 12

    DS6500 PROFIBUS MODEL 26-pin D-Sub Connector Pinout Pin Name Function Chassis - internally connected to GND 1 CHASSIS Cable shield connected to chassis 20 RX AU X Receive data of auxiliary RS232 (referred to GND) 21 TXAU X Transmit data of auxiliary RS232 (referred to GND) 8 OUT 1+ Configurable digi tal output 1 – positive pin 22 OUT 1- Configura ...

  • Datalogic DS6500 - page 13

    DS6500 PROFIBUS MODEL Connectivity: Point-to-Point Layout Remote Host Fieldbus Netw ork DS6500 C-BOX 100 CAB-601X *P.S. PG6000 * P.S. (Presence Sensor) connect ed to External Trigger/PS input. Pass Through Layout Remote Host E N T < < E N T < < *P.S. *P.S. Gryphon Fieldbus Network DS4600A DS4600A DS6500 CAB-601 X C-BOX 100 C-BOX 100 AUX ...

  • Datalogic DS6500 - page 14

    DS6500 PROFIBUS MODEL Local Lonworks Netw ork Remote Host Fieldbus Network Master Slave 2*** Slave 1*** C-BOX 100** CAB-610X CAB-610X CAB-60XX P.S.* CAB-610X Encoder**** CAB-610X CAB-610X CAB-63XX BTK-6000 Slave 3*** Slave 5*** Slave 4*** PWR-240 CAB-63XX Fieldbus Small Synchronized Network * P.S. (Presence Sensor) connect ed to External Trigger/PS ...

  • Datalogic DS6500 - page 15

    DS6500 ETHERNET MODEL DS6500-100-012 ETHERNET MODEL Figure A Laser Beam Output W indow 1 Figure B Programming Keyp ad 1 Phase On LED (Yellow) 3 TX Data LED (Gree n) 2 Pow er On L ED (Re d) 4 LCD Display 5 Figure C RJ45 Modular Connect or f or Ethe rnet Inter fac e 1 Lonworks 9-pi n Female Con nector 2 Ma in/Aux. Interface 2 6-pin D -Sub M ale C onn ...

  • Datalogic DS6500 - page 16

    DS6500 ETHERNET MODEL SOFTWA RE FEA TURES ENVIRONMENTA L FEA TURES Interleaved 2/5 Readable Codes Code 39 standard Operating Temperature 0° to +40 °C (+32 to +104 °F) Codabar Code 128 Storage Temperature -20° to +70 °C (-4° to +158 °F) EAN 128 Humidity 90% non condensing Code 93 (Standard & Full ASCII) A mbient Light EAN/UPC (including A ...

  • Datalogic DS6500 - page 17

    DS6500 ETHERNET MODEL 26-pin D-Sub Connector Pinout Pin Name Function Chassis - internally connected to GND 1 CHASSIS Cable shield connected to chassis 20 RX AU X Receive data of auxiliary RS232 (referred to GND) 21 TXAU X Transmit data of auxiliary RS232 (referred to GND) 8 OUT 1+ Configurable digi tal output 1 – positive pin 22 OUT 1- Configura ...

  • Datalogic DS6500 - page 18

    DS6500 ETHERNET MODEL Connectivity: Point-to-Point Layout Remote Host Fieldbus Netw ork DS6500 C-BOX 100 CAB-601X *P.S. PG6000 * P.S. (Presence Sensor) connect ed to External Trigger/PS input. Pass Through Layout Remote Host E N T < < E N T < < *P.S. *P.S. Gryphon Fieldbus Network DS4600A DS4600A DS6500 CAB-601X C-BOX 100 C-BOX 100 AUX ...

  • Datalogic DS6500 - page 19

    DS6500 ETHERNET MODEL Local Lonworks Netw ork Remote Host Fieldbus Network Master Slave 2*** Slave 1*** C-BOX 100** CAB-610X CAB-610X CAB-60XX P.S.* CAB-610X Encoder**** CAB-610X CAB-610X CAB-63XX BTK-6000 Slave 3*** Slave 5*** Slave 4*** PWR-240 CAB-63XX Fieldbus Small Synchronized Network * P.S. (Presence Sensor) connect ed to External Trigger/PS ...

  • Datalogic DS6500 - page 20

    DS6500 DEVICENET MODEL DS6500-100-015 DEVICENET MODEL Figure A Laser Beam Output W indow 1 Figure B Figure C Programming Keyp ad 1 Phase On LED (Yellow) 3 TX Data LED (Gree n) 2 Pow er On L ED (Re d) 4 LCD Display 5 Main/Aux. I nterf ace 26 -pin D-su b Male Connector 1 Lonworks 9-pi n Female Con nector 2 DeviceNet 5 -pin Male Conn ector 3 1 2 3 4 5 ...

  • Datalogic DS6500 - page 21

    DS6500 DEVICENET MODEL SOFTWA RE FEA TURES ENVIRONMENTA L FEA TURES Interleaved 2/5 Readable Codes Code 39 standard Operating Temperature 0° to +40 °C (+32 to +104 °F) Codabar Code 128 Storage Temperature -20° to +70 °C (-4° to +158 °F) EAN 128 Humidity 90% non condensing Code 93 (Standard & Full ASCII) A mbient Light EAN/UPC (including ...

  • Datalogic DS6500 - page 22

    DS6500 DEVICENET MODEL The details of the connector pins ar e indicated in the following table: 26-pin D-Sub Connector Pinout Pin Name Function Chassis - internally connected to GND 1 CHASSIS Cable shield connected to chassis 20 RX AU X Receive data of auxiliary RS232 (referred to GND) 21 TXAU X Transmit data of auxiliary RS232 (referred to GND) 8 ...

  • Datalogic DS6500 - page 23

    DS6500 DEVICENET MODEL Connectivity: Point-to-Point Layout Remote Host Fieldbus Network DS6500 C-BOX 100 CAB-601X *P.S. PG6000 * P.S. (Presence Sensor) connect ed to External Trigger/PS input. Pass Through Layout Remote Host E N T < < E N T < < *P.S. *P.S. Gryphon Fieldbus Network DS4600A DS4600A DS6500 CAB 601X C-BOX 100 C-BOX 100 AUX ...

  • Datalogic DS6500 - page 24

    DS6500 DEVICENET MODEL Local Lonworks Netw ork Remote Host Fieldbus Network Master Slave 2*** Slave 1*** C-BOX 100** CAB-610X CAB-610X CAB-60XX P.S.* CAB-610X Encoder**** CAB-610X CAB-610X CAB-63XX BTK-6000 Slave 3*** Slave 5*** Slave 4*** PWR-240 CAB-63XX Fieldbus Small Synchronized Network * P.S. (Presence Sensor) connect ed to External Trigger/P ...

  • Datalogic DS6500 - page 25

    DS6500 OSCILLATING MIRROR MODEL DS6500-105-0XX OSCILLATING MIRROR MODEL Figure A Laser Beam Output W indow 1 1 Oscillating mirror models are used when coverage of a lar ge reading area is required, mainly in picket fence applications. The DS6500 scanner mounts a dedicated optic head with int egrated oscillating mirror driven by a linear motor. The ...

  • Datalogic DS6500 - page 26

    DS6500 OSCILLATING MIRROR MODEL In the above case, the zone where the scan line is perpendicular to the reflec ting surface corresponds to a neutral zone at the center of the reading field. The mirror can be deflected up to 40°. Oscillation with res pect to the output window medi an axis is asymmetrical (see figure below). 40° 3 7 . 5 ° 0° - 2 ...

  • Datalogic DS6500 - page 27

    COMMON FEATURES COMMON FEATURES C-BOX 100 Pinout for DS6500: The table below gives the pinout of the C-BOX 100 terminal block connecto rs. Use this pinout when the DS6500 reader is connected in a network by means of the C-BOX 100: C-BOX 100 Terminal Block Connectors Pow er 1, 3, 5 VS 2, 4, 6 GND 7, 8 EARTH GROUND 20, 40 Reserved Inputs 27 EXT T RIG ...

  • Datalogic DS6500 - page 28

    COMMON FEATURES Mechanical Installation: The DS6500 reader can be positioned and in stalled in the best way possible as a result of the Step-A-Head TM feature. Thanks to the s eparation between Head and Base, you can modify the orientation of the decoder base, and therefore display-keypad and connector panels, w hile k eeping the optic head in the ...

  • Datalogic DS6500 - page 29

    COMMON FEATURES Typical Installations: Standard Installation The DS6500 scanner is mounted on the ST -237 106° mounting bracket w hic h guarantees a built-in Skew angle ( S in the figure below) of 16° w ith respect to the frame plane (typically the Skew angle should be between 10° - 20°). This avoids the direct reflection of the laser light emi ...

  • Datalogic DS6500 - page 30

    COMMON FEATURES Minimum Code Height for A CR Reading (mm) 45° 30° Conveyor Speed (m/s) 0.5 1 1. 5 2 2.5 3 0.5 1 1.5 2 2.5 3 0.25 10 12 14 16 18 20 7 9 10 12 13 15 0.30 12 14 15 17 19 21 8 9 11 12 14 15 0.33 13 14 16 18 20 22 8 10 11 13 14 16 0.38 14 16 18 19 21 23 9 11 12 14 15 17 0.50 18 19 21 23 25 26 11 12 14 15 17 18 0.72 24 25 27 28 30 32 15 ...

  • Datalogic DS6500 - page 31

    COMMON FEATURES Reading Diagrams: In the following reading diagrams (0,0) is t he center of the laser beam output w indow . DS6500-100-0XX CONDITIONS Code = Interleaved 2/5 o r Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0° 0 4 (in) 81 2 1 6 0 10 20 30 40 50 (cm) 60 20 24 80 32 (in) (cm) 0 -10 -20 -30 -8 -12 -4 0 -40 ...

  • Datalogic DS6500 - page 32

    COMMON FEATURES Reading Diagrams: DS6500-200-0XX CONDITIONS Code = Interleaved 2/5 o r Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0° 0 14 (in) 20 26 32 0 35 50 6 5 80 95 (cm ) 110 38 44 140 56 (in) (c m) 0 -15 -30 -45 -12 -18 -6 0 -60 -24 -75 -30 15 6 30 12 0.5 mm (20 mils) 155 62 170 68 125 50 60 24 75 30 45 18 0.3 ...

  • Datalogic DS6500 - page 33

    COMMON FEATURES User Interface: RS232 PC-side connections 1 5 9 6 9-pin male connector 13 25 14 1 25-pin male connec tor Pin Name Pin Name 2 RX 3 RX 3 TX 2 TX 5 GND 7 GND 7 RTS 4 RTS 8 CTS 5 CTS How To Build A Simple Interface Test Cable: The following w iring diagram shows a simple test cable including power, external (push-button) trigger and PC ...

  • Datalogic DS6500 - page 34

    COMMON FEATURES Compliance: Laser Safety Figure A Laser Saf ety Label 1 Identif ication Label 2 Figure B W arning and Device Class Label 1 Figure C Laser Safety Label 1 1 2 1 1 The scanner is classified as a Class 2 laser product according to EN 60825-1 regulations and as a Class II laser product according to CDRH regulations. Disconnect the power ...

  • Datalogic DS6500 - page 35

    COMMON FEATURES The laser diode used in this device is classified as a Class 3B laser product according to EN 60825-1 regulations and as a Class IIIb laser product according to CDRH regulati ons. As it is not possible to apply a classification label on the laser diode used in this devic e, the following label is reproduced below : LASER LIGHT AVOID ...

  • Datalogic DS6500 - page 36

    DATALOGIC S.p.A., DATALOGIC S.p.A., 05 Via Candini, 2 Via Candini, 2 40012 - Lippo di Calderara 40012 - Lippo di Calderara Bologna - Italy Bologna - Italy dichiara che dichi ara che declares that the declares that the déclare que le déclare que le bescheinigt, daß das Gerät bescheinigt, daß das Gerät declare que el declare que el DS6500-XXX-X ...

Fabbricante Datalogic Categoria Scanner

I documenti che otteniamo dal fabbricante del dispositivoDatalogic DS6500 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Datalogic
- manuali per l’uso DS6500
- schede prodotto Datalogic
- opuscoli
- o etichette energetiche Datalogic DS6500
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Datalogic DS6500.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Datalogic DS6500, manuali di manutenzione, brevi manuali o manuali utente Datalogic DS6500. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Datalogic DS6500.

Manuali per l’uso simili

Manuale completo del dispositivo Datalogic DS6500, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Datalogic DS6500 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Datalogic DS6500.

Il manuale per l’uso completo Datalogic, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Datalogic DS6500 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Datalogic DS6500, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Datalogic DS6500 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Datalogic DS6500 - che ci dovrebbe aiutare nei primi passi durante l'uso Datalogic DS6500
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Datalogic DS6500
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Datalogic DS6500 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Datalogic DS6500?

Utilizza il modulo sottostante

Se non hai risolto il problema con Datalogic DS6500 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Datalogic DS6500 è probabile che voglia condividere il modo di risolverlo.