Инструкция обслуживания Datalogic DS6500

36 страниц 4.03 mb
Скачать

Перейти на страницу of 36

Summary
  • Datalogic DS6500 - page 1

    DS6500 INSTA LLA TION QUICK REFERENCE ...

  • Datalogic DS6500 - page 2

    CONTENTS DS6500-100-010 M ASTER/SLAVE MODEL ........................................................................................................... 1 DS6500-100-011 PROFIBUS MODEL ..................................................................................................................... 8 DS6500-100-012 ET HERNET MODEL ............... ...

  • Datalogic DS6500 - page 3

    DS6500 MASTER/SLAVE MODEL DS6500-100-010 MASTER/SLAVE MODEL Figure A Laser Beam Output W indow 1 Figure B Programming Keyp ad 1 Phase On LED (Yellow) 3 TX Data LED (Gree n) 2 Pow er On L ED (Re d) 4 LCD Display 5 Figure C Main/Aux. I nterf ace 25 -pin D-su b Male Connector 1 Lonworks 9-pin Male Connecto r 2 Lonworks 9-pi n Female Con nector 3 2 3 4 ...

  • Datalogic DS6500 - page 4

    DS6500 MASTER/SLAVE MODEL SOFTWA RE FEA TURES ENVIRONMENTA L FEA TURES Interleaved 2/5 Readable Codes Code 39 standard Operating Temperature 0° to +40 °C (+32 to +104 °F) Codabar Code 128 Storage Temperature -20° to +70 °C (-4° to +158 °F) EAN 128 Humidity 90% non condensing Code 93 (Standard & Full ASCII) A mbient Light EAN/UPC (includi ...

  • Datalogic DS6500 - page 5

    DS6500 MASTER/SLAVE MODEL The details of the connector pins ar e indicated in the following table: 25-pin D-Sub Connector Pinout Pin Name Function Chassis - internally connected to GND 1 CHASSIS Cable shield connected to chassis 20 RX AU X Receive data of auxiliary RS232 (referred to GND) 21 TXAU X Transmit data of auxiliary RS232 (referred to GND) ...

  • Datalogic DS6500 - page 6

    DS6500 MASTER/SLAVE MODEL Connectivity: Point-to-Point Layout DS6500 CAB-600X C-BOX 100 Local Host *P.S. PG6000 * P.S. (Presence Sensor) connect ed to External Trigger/PS input. Pass Through Layout E N T < < E N T < < *P.S. *P.S. Gryphon DS4600A DS4600A DS6500 CAB-600X C-BOX 100 C-BOX 100 C-BOX 100 A U X MAIN *P.S. 2 2 1 1 Local Host 1 ...

  • Datalogic DS6500 - page 7

    DS6500 MASTER/SLAVE MODEL Multiplexer Layout E N T < < E N T < < *P.S. *P.S. DS4600A DS4600A DS6500 PWR-120 CAB-600X C-BOX 100 C-BOX 100 C-BOX 100 MX4000 #0 1 #31 #1 Local Host 1 RS485 HD M ain Interface * P.S. (Presence Sensor) connect ed to External Trigger/PS input. RS232 Master/Slave Lay out E N T < < E N T < < DS6500 Ma ...

  • Datalogic DS6500 - page 8

    DS6500 MASTER/SLAVE MODEL Local Lonworks Netw ork CAB-60XX CAB-610X BTK-6000 C-BOX 100** Master Encoder*** BTK-6000 Slave 1 *P.S. Local Host CAB-63XX PWR-120 Small Synchronized Network w ith 2 Readers * P.S. (Presence Sensor) connect ed to External Trigger/PS input. ** C-BOX 100 modified to accept scanner power. *** Encoder connected to IN2/ENC inp ...

  • Datalogic DS6500 - page 9

    DS6500 MASTER/SLAVE MODEL Large Synchronized Ne tw ork ** * * P.S. (Presence Sensor) connect ed to External Trigger/PS input. ** Encoder connected to IN2/ENC input. Large Synchronized Network wi th DX6X00 and DS6XXX Scanners . 7 ...

  • Datalogic DS6500 - page 10

    DS6500 PROFIBUS MODEL DS6500-100-011 PROFIBUS MODEL Figure A Laser Beam Output W indow 1 Figure B Programming Keyp ad 1 Phase On LED (Yellow) 3 TX Data LED (Gree n) 2 Pow er On L ED (Re d) 4 LCD Display 5 Figure C Prof ibus 9- pin Female Connector (whit e) 1 Lonworks 9-pin Female Con nector 2 Ma in/Aux. Interface 2 6-pin D -Sub M ale Co nnector 3 1 ...

  • Datalogic DS6500 - page 11

    DS6500 PROFIBUS MODEL SOFTWA RE FEA TURES ENVIRONMENTA L FEA TURES Interleaved 2/5 Readable Codes Code 39 standard Operating Temperature 0° to +40 °C (+32 to +104 °F) Codabar Code 128 Storage Temperature -20° to +70 °C (-4° to +158 °F) EAN 128 Humidity 90% non condensing Code 93 (Standard & Full ASCII) A mbient Light EAN/UPC (including A ...

  • Datalogic DS6500 - page 12

    DS6500 PROFIBUS MODEL 26-pin D-Sub Connector Pinout Pin Name Function Chassis - internally connected to GND 1 CHASSIS Cable shield connected to chassis 20 RX AU X Receive data of auxiliary RS232 (referred to GND) 21 TXAU X Transmit data of auxiliary RS232 (referred to GND) 8 OUT 1+ Configurable digi tal output 1 – positive pin 22 OUT 1- Configura ...

  • Datalogic DS6500 - page 13

    DS6500 PROFIBUS MODEL Connectivity: Point-to-Point Layout Remote Host Fieldbus Netw ork DS6500 C-BOX 100 CAB-601X *P.S. PG6000 * P.S. (Presence Sensor) connect ed to External Trigger/PS input. Pass Through Layout Remote Host E N T < < E N T < < *P.S. *P.S. Gryphon Fieldbus Network DS4600A DS4600A DS6500 CAB-601 X C-BOX 100 C-BOX 100 AUX ...

  • Datalogic DS6500 - page 14

    DS6500 PROFIBUS MODEL Local Lonworks Netw ork Remote Host Fieldbus Network Master Slave 2*** Slave 1*** C-BOX 100** CAB-610X CAB-610X CAB-60XX P.S.* CAB-610X Encoder**** CAB-610X CAB-610X CAB-63XX BTK-6000 Slave 3*** Slave 5*** Slave 4*** PWR-240 CAB-63XX Fieldbus Small Synchronized Network * P.S. (Presence Sensor) connect ed to External Trigger/PS ...

  • Datalogic DS6500 - page 15

    DS6500 ETHERNET MODEL DS6500-100-012 ETHERNET MODEL Figure A Laser Beam Output W indow 1 Figure B Programming Keyp ad 1 Phase On LED (Yellow) 3 TX Data LED (Gree n) 2 Pow er On L ED (Re d) 4 LCD Display 5 Figure C RJ45 Modular Connect or f or Ethe rnet Inter fac e 1 Lonworks 9-pi n Female Con nector 2 Ma in/Aux. Interface 2 6-pin D -Sub M ale C onn ...

  • Datalogic DS6500 - page 16

    DS6500 ETHERNET MODEL SOFTWA RE FEA TURES ENVIRONMENTA L FEA TURES Interleaved 2/5 Readable Codes Code 39 standard Operating Temperature 0° to +40 °C (+32 to +104 °F) Codabar Code 128 Storage Temperature -20° to +70 °C (-4° to +158 °F) EAN 128 Humidity 90% non condensing Code 93 (Standard & Full ASCII) A mbient Light EAN/UPC (including A ...

  • Datalogic DS6500 - page 17

    DS6500 ETHERNET MODEL 26-pin D-Sub Connector Pinout Pin Name Function Chassis - internally connected to GND 1 CHASSIS Cable shield connected to chassis 20 RX AU X Receive data of auxiliary RS232 (referred to GND) 21 TXAU X Transmit data of auxiliary RS232 (referred to GND) 8 OUT 1+ Configurable digi tal output 1 – positive pin 22 OUT 1- Configura ...

  • Datalogic DS6500 - page 18

    DS6500 ETHERNET MODEL Connectivity: Point-to-Point Layout Remote Host Fieldbus Netw ork DS6500 C-BOX 100 CAB-601X *P.S. PG6000 * P.S. (Presence Sensor) connect ed to External Trigger/PS input. Pass Through Layout Remote Host E N T < < E N T < < *P.S. *P.S. Gryphon Fieldbus Network DS4600A DS4600A DS6500 CAB-601X C-BOX 100 C-BOX 100 AUX ...

  • Datalogic DS6500 - page 19

    DS6500 ETHERNET MODEL Local Lonworks Netw ork Remote Host Fieldbus Network Master Slave 2*** Slave 1*** C-BOX 100** CAB-610X CAB-610X CAB-60XX P.S.* CAB-610X Encoder**** CAB-610X CAB-610X CAB-63XX BTK-6000 Slave 3*** Slave 5*** Slave 4*** PWR-240 CAB-63XX Fieldbus Small Synchronized Network * P.S. (Presence Sensor) connect ed to External Trigger/PS ...

  • Datalogic DS6500 - page 20

    DS6500 DEVICENET MODEL DS6500-100-015 DEVICENET MODEL Figure A Laser Beam Output W indow 1 Figure B Figure C Programming Keyp ad 1 Phase On LED (Yellow) 3 TX Data LED (Gree n) 2 Pow er On L ED (Re d) 4 LCD Display 5 Main/Aux. I nterf ace 26 -pin D-su b Male Connector 1 Lonworks 9-pi n Female Con nector 2 DeviceNet 5 -pin Male Conn ector 3 1 2 3 4 5 ...

  • Datalogic DS6500 - page 21

    DS6500 DEVICENET MODEL SOFTWA RE FEA TURES ENVIRONMENTA L FEA TURES Interleaved 2/5 Readable Codes Code 39 standard Operating Temperature 0° to +40 °C (+32 to +104 °F) Codabar Code 128 Storage Temperature -20° to +70 °C (-4° to +158 °F) EAN 128 Humidity 90% non condensing Code 93 (Standard & Full ASCII) A mbient Light EAN/UPC (including ...

  • Datalogic DS6500 - page 22

    DS6500 DEVICENET MODEL The details of the connector pins ar e indicated in the following table: 26-pin D-Sub Connector Pinout Pin Name Function Chassis - internally connected to GND 1 CHASSIS Cable shield connected to chassis 20 RX AU X Receive data of auxiliary RS232 (referred to GND) 21 TXAU X Transmit data of auxiliary RS232 (referred to GND) 8 ...

  • Datalogic DS6500 - page 23

    DS6500 DEVICENET MODEL Connectivity: Point-to-Point Layout Remote Host Fieldbus Network DS6500 C-BOX 100 CAB-601X *P.S. PG6000 * P.S. (Presence Sensor) connect ed to External Trigger/PS input. Pass Through Layout Remote Host E N T < < E N T < < *P.S. *P.S. Gryphon Fieldbus Network DS4600A DS4600A DS6500 CAB 601X C-BOX 100 C-BOX 100 AUX ...

  • Datalogic DS6500 - page 24

    DS6500 DEVICENET MODEL Local Lonworks Netw ork Remote Host Fieldbus Network Master Slave 2*** Slave 1*** C-BOX 100** CAB-610X CAB-610X CAB-60XX P.S.* CAB-610X Encoder**** CAB-610X CAB-610X CAB-63XX BTK-6000 Slave 3*** Slave 5*** Slave 4*** PWR-240 CAB-63XX Fieldbus Small Synchronized Network * P.S. (Presence Sensor) connect ed to External Trigger/P ...

  • Datalogic DS6500 - page 25

    DS6500 OSCILLATING MIRROR MODEL DS6500-105-0XX OSCILLATING MIRROR MODEL Figure A Laser Beam Output W indow 1 1 Oscillating mirror models are used when coverage of a lar ge reading area is required, mainly in picket fence applications. The DS6500 scanner mounts a dedicated optic head with int egrated oscillating mirror driven by a linear motor. The ...

  • Datalogic DS6500 - page 26

    DS6500 OSCILLATING MIRROR MODEL In the above case, the zone where the scan line is perpendicular to the reflec ting surface corresponds to a neutral zone at the center of the reading field. The mirror can be deflected up to 40°. Oscillation with res pect to the output window medi an axis is asymmetrical (see figure below). 40° 3 7 . 5 ° 0° - 2 ...

  • Datalogic DS6500 - page 27

    COMMON FEATURES COMMON FEATURES C-BOX 100 Pinout for DS6500: The table below gives the pinout of the C-BOX 100 terminal block connecto rs. Use this pinout when the DS6500 reader is connected in a network by means of the C-BOX 100: C-BOX 100 Terminal Block Connectors Pow er 1, 3, 5 VS 2, 4, 6 GND 7, 8 EARTH GROUND 20, 40 Reserved Inputs 27 EXT T RIG ...

  • Datalogic DS6500 - page 28

    COMMON FEATURES Mechanical Installation: The DS6500 reader can be positioned and in stalled in the best way possible as a result of the Step-A-Head TM feature. Thanks to the s eparation between Head and Base, you can modify the orientation of the decoder base, and therefore display-keypad and connector panels, w hile k eeping the optic head in the ...

  • Datalogic DS6500 - page 29

    COMMON FEATURES Typical Installations: Standard Installation The DS6500 scanner is mounted on the ST -237 106° mounting bracket w hic h guarantees a built-in Skew angle ( S in the figure below) of 16° w ith respect to the frame plane (typically the Skew angle should be between 10° - 20°). This avoids the direct reflection of the laser light emi ...

  • Datalogic DS6500 - page 30

    COMMON FEATURES Minimum Code Height for A CR Reading (mm) 45° 30° Conveyor Speed (m/s) 0.5 1 1. 5 2 2.5 3 0.5 1 1.5 2 2.5 3 0.25 10 12 14 16 18 20 7 9 10 12 13 15 0.30 12 14 15 17 19 21 8 9 11 12 14 15 0.33 13 14 16 18 20 22 8 10 11 13 14 16 0.38 14 16 18 19 21 23 9 11 12 14 15 17 0.50 18 19 21 23 25 26 11 12 14 15 17 18 0.72 24 25 27 28 30 32 15 ...

  • Datalogic DS6500 - page 31

    COMMON FEATURES Reading Diagrams: In the following reading diagrams (0,0) is t he center of the laser beam output w indow . DS6500-100-0XX CONDITIONS Code = Interleaved 2/5 o r Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0° 0 4 (in) 81 2 1 6 0 10 20 30 40 50 (cm) 60 20 24 80 32 (in) (cm) 0 -10 -20 -30 -8 -12 -4 0 -40 ...

  • Datalogic DS6500 - page 32

    COMMON FEATURES Reading Diagrams: DS6500-200-0XX CONDITIONS Code = Interleaved 2/5 o r Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0° 0 14 (in) 20 26 32 0 35 50 6 5 80 95 (cm ) 110 38 44 140 56 (in) (c m) 0 -15 -30 -45 -12 -18 -6 0 -60 -24 -75 -30 15 6 30 12 0.5 mm (20 mils) 155 62 170 68 125 50 60 24 75 30 45 18 0.3 ...

  • Datalogic DS6500 - page 33

    COMMON FEATURES User Interface: RS232 PC-side connections 1 5 9 6 9-pin male connector 13 25 14 1 25-pin male connec tor Pin Name Pin Name 2 RX 3 RX 3 TX 2 TX 5 GND 7 GND 7 RTS 4 RTS 8 CTS 5 CTS How To Build A Simple Interface Test Cable: The following w iring diagram shows a simple test cable including power, external (push-button) trigger and PC ...

  • Datalogic DS6500 - page 34

    COMMON FEATURES Compliance: Laser Safety Figure A Laser Saf ety Label 1 Identif ication Label 2 Figure B W arning and Device Class Label 1 Figure C Laser Safety Label 1 1 2 1 1 The scanner is classified as a Class 2 laser product according to EN 60825-1 regulations and as a Class II laser product according to CDRH regulations. Disconnect the power ...

  • Datalogic DS6500 - page 35

    COMMON FEATURES The laser diode used in this device is classified as a Class 3B laser product according to EN 60825-1 regulations and as a Class IIIb laser product according to CDRH regulati ons. As it is not possible to apply a classification label on the laser diode used in this devic e, the following label is reproduced below : LASER LIGHT AVOID ...

  • Datalogic DS6500 - page 36

    DATALOGIC S.p.A., DATALOGIC S.p.A., 05 Via Candini, 2 Via Candini, 2 40012 - Lippo di Calderara 40012 - Lippo di Calderara Bologna - Italy Bologna - Italy dichiara che dichi ara che declares that the declares that the déclare que le déclare que le bescheinigt, daß das Gerät bescheinigt, daß das Gerät declare que el declare que el DS6500-XXX-X ...

Производитель Datalogic Категория Scanner

Документы, которые мы получаем от производителя устройства Datalogic DS6500 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Datalogic
- инструкции обслуживания DS6500
- паспорта изделия Datalogic
- информационные брошюры
- энергетические этикетки Datalogic DS6500
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Datalogic DS6500.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Datalogic DS6500, инструкции обслуживания, короткие инструкции или инструкции пользователя Datalogic DS6500. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Datalogic DS6500.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Datalogic DS6500, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Datalogic DS6500 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Datalogic DS6500.

Полная инструкция обслуживания Datalogic, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Datalogic DS6500 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Datalogic DS6500, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Datalogic DS6500, которое найдем в данном документе
3. Советы по использованию основных функций устройства Datalogic DS6500 - которые должны облегчить нам первые шаги во время использования Datalogic DS6500
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Datalogic DS6500
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Datalogic DS6500 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Datalogic DS6500?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Datalogic DS6500, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Datalogic DS6500 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)