  • York AHP18 THRU 60 - page 1

    TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT -SYSTEM COOLING & HEA T PUMPS MODELS: AHP18 THRU 60 AND SHP48 THRU 60 Due to continuous product im provement, specifications are subjec t to ch a nge without notic e. V isit us on the web at www .york.com Additional rati ng information ca n be found at www .ari.org/ari directory . ISO ...

  • York AHP18 THRU 60 - page 2

    255029-YTG-J-1007 2 Unitary Products Group DIMENSIONS 10-3/8” F CIRCUIT BREAKER P ANEL BOTTOM INLET DIMENSIONS DRAIN P AN CONNECTIONS FOR HORIZONT AL APPLICATIONS J BLOWER COMP ARTMENT REFRIGERANT CONNECTIONS DRAIN CONNECTIONS FOR UPFLOW AND DOWNFLOW APPLICA TIONS 7-1 1/32” D B A K C 1-1/2” 18-9/32” E TOP OUTLET DIMENSIONS FIL TER ACCESS DI ...

  • York AHP18 THRU 60 - page 3

    255029-YTG-J-1007 Unitary Products Group 3 COOLING CAP ACITY Models Rated CFM Entering Air °F (Dry / Wet Bulb) MBH@ Evaporator T emperature and Corresponding Pressure °F / PSIG 35 / 61.5 40 / 68.5 45 / 76.0 50 / 84.0 FULL-CASED “A” TYPE MUL TI-POSITION AHP18B2A(N,H)21 650 85/72 24.5 22.3 19.9 17.3 80/67 22.6 20.3 18.0 15.6 75/62 18.5 16.4 14. ...

  • York AHP18 THRU 60 - page 4

    255029-YTG-J-1007 4 Unitary Products Group ACCESSORIES Refer to Price Manual for specific model numbers. TXV Kits - TXV kits are available for “Flex-coil” applica tions and converting R22 to R410A or as a service replacement. All kits are bolt-on and require no brazing to install. Non-Combustible Bases - A combustible floor base acces- sory is ...

  • York AHP18 THRU 60 - page 5

    255029-YTG-J-1007 Unitary Products Group 5 All air handle r units are UL Liste d up to 0.50" w.c. external static press ure, incl ud ing air fil ter , wet coil, an d l argest KW s ize heater, unless otherwise noted. AIR FLOW DA T A - 60 Hz MODELS Models Blower Motor Speed 230 V olt CFM 1 @ External St atic Pressure - IWC 0.10 0.20 0.30 0.40 0. ...

  • York AHP18 THRU 60 - page 6

    255029-YTG-J-1007 6 Unitary Products Group PHYSICAL & ELECTRICAL DA T A Models AHP18B**(N,H)21 AHP24B**(N,H)21 AHP30B**(N,H)21 AHP36C **(N,H)21 Blower - Diameter x Width 9 x 6 10 x 9 10 x 9 10 x 10 Motor HP 1/3 HP 1/4 HP 1/2 HP 3/4 HP Nominal RPM 1075 1075 1075 1075 V oltage 230 Amps Full Load ( 230) 1.9 1.5 2.2 3.6 Filter 1 T ype DISPOSABLE OR ...

  • York AHP18 THRU 60 - page 7

    255029-YTG-J-1007 Unitary Products Group 7 * May be 0 (no breaker) or 1 (with breaker). ELECTRICAL DA T A - 208/230-1-60 Models Heater Models* Max. Static Min. Speed Ta p T otal Heat 1 kW St a ging kW MBH W1 Only W2 Only W1 + W2 208V 240V 208V 2 40V 208V 240V 208V 240V 208V 240V AHP18B**(N,H)21 4HK*6500206 0.5 Lo 1.9 2.5 6.4 8.5 1.9 2.5 1 .9 2.5 1. ...

  • York AHP18 THRU 60 - page 8

    255029-YTG-J-1007 8 Unitary Products Group * May be 0 (no breaker) or 1 (with breaker). ELECTRICAL DA T A (FOR SI NGLE SOURCE POWER SUPPL Y) - COPPER WIRE 208/230-1-60 Models Heater Models* Heater Amps 240V Field Wiring Min. Circuit Ampacity Max. O.C.P . 1 Amps/T ype 75 ° C Wire Size - AWG 208V 240V 208V 2 40V 208V 240V AHP18B**(N,H)21 4HK*6500206 ...

  • York AHP18 THRU 60 - page 9

    255029-YTG-J-1007 Unitary Products Group 9 ELECTRICAL DA T A (FOR MUL TI SOURCE PO WER SUPPL Y) - COPPER WIRE 208/230-1-60 Models Heater Models Min. Circuit Ampacity Max. O.C.P . 1 Amp s/T ype 75 ° C Wire Size - A WG Circuit Circuit Circuit 1st 2nd 3rd 1st 2nd 3rd 1st 2nd 3rd 208/240 208/240 208/240 208/240 208/240 208/240 208/240 208/240 208/240 ...

  • York AHP18 THRU 60 - page 10

    255029-YTG-J-1007 10 Unitary Products Group 2. Heaters are 3 Phase. ELECTRICAL DA T A (FOR SI NGLE SOURCE POWER SUPPL Y) - COPPER WIRE 208/230-3-60 Models Heat Kit - Three Phase Heater Amps 240V Field Wiring Min. Circuit Ampacity Max. O.C.P . 1 Amp s/T ype 75 ° C Wire Size - A WG 208V 240V 208V 2 40V 208V 240V AHP24B**(N,H)21 4HK06501025 23.1 27.1 ...

  • York AHP18 THRU 60 - page 11

    255029-YTG-J-1007 Unitary Products Group 11 COOLING MODELS W ITH ELECTRIC HEA T WI RING * O ptional dehumidification humidistat switch contacts open on humidity rise. Notes: 1. “Y” T erminal on Air Handler Control Boa rd must be connecte d for full CFM and applications requiring 60 second blower off del ay for SEER enhancement. 2. Move HUM ST A ...

  • York AHP18 THRU 60 - page 12

    Subject to change without notice. Printe d in U.S.A. 255029-YTG-J-1007 Copyright © by Unitary Products Gr oup. 2007. All rights reserved. Supersedes: 255029-YTG-I-0507 Unitary 5005 Norman Product s Y ork OK Group Drive 73069 TYPICAL APPLICA TIONS UPFLOW DOWNFLOW HORIZONT AL RIGHT HORIZONT AL LEFT ...

Fabbricante York Categoria Heat Pump

I documenti che otteniamo dal fabbricante del dispositivoYork AHP18 THRU 60 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici York
- manuali per l’uso AHP18 THRU 60
- schede prodotto York
- opuscoli
- o etichette energetiche York AHP18 THRU 60
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso York AHP18 THRU 60.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione York AHP18 THRU 60, manuali di manutenzione, brevi manuali o manuali utente York AHP18 THRU 60. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto York AHP18 THRU 60.

Manuali per l’uso simili

Manuale completo del dispositivo York AHP18 THRU 60, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare York AHP18 THRU 60 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti York AHP18 THRU 60.

Il manuale per l’uso completo York, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale York AHP18 THRU 60 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice York AHP18 THRU 60, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per York AHP18 THRU 60 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo York AHP18 THRU 60 - che ci dovrebbe aiutare nei primi passi durante l'uso York AHP18 THRU 60
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del York AHP18 THRU 60
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio York AHP18 THRU 60 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su York AHP18 THRU 60?

Utilizza il modulo sottostante

Se non hai risolto il problema con York AHP18 THRU 60 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con York AHP18 THRU 60 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)