    technic al guide W a t e r S o u r c e He at P umps ...

  • York YK145.00-EG4 - page 2

    2 Johnson Controls T echnical Guide: YK145.00-EG4 (309) W ater Source Heat Pumps Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • York YK145.00-EG4 - page 3

    Johnson Controls 3 W ater Source Heat Pumps T echnical Guide: YK145.00-EG4 (309) INTR ODUCTION Performance and dependability in a no-nonsense heat pump. The R-Series units by YORK are completely self-contained heat pumps. This equipment employs a water-to- refrigerant heat exchanger to extract (heating cycle) or reject (cooling cycle) heat from/to ...

  • York YK145.00-EG4 - page 4

    4 Johnson Controls T echnical Guide: YK145.00-EG4 (309) W ater Source Heat Pumps SPECIFICA TIONS GENERAL All R-series models ½ - 6 ton ship as factory-charged packages, complete with R-410A refrigerant. Horizontal (RSH) units are designed for suspended ceiling mount- ing. RSH models are shipped with ‘straight-through’ evaporator fan discharge ...

  • York YK145.00-EG4 - page 5

    Johnson Controls 5 W ater Source Heat Pumps T echnical Guide: YK145.00-EG4 (309) NOMENCLA TURE WA TER SOUR CE HEA T PUMP Product Category RS = Water-Cooled HP R-410A Product Indentifier V = Vertical Arrangement (Upflow) H = Horizontal Arrangment Miscellaneous Options A = None D = Condensate Overflow Switch Heating Options 0 = None Design Series t n ...

  • York YK145.00-EG4 - page 6

    6 Johnson Controls T echnical Guide: YK145.00-EG4 (309) W ater Source Heat Pumps PHY SICAL D A T A Model Series 007 009 012 018 024 030 036 042 048 060 070 Nominal Cooling (T on) 1 0.5 0.75 1.0 1.5 2.0 2.5 3 3.5 4 5 6 Compressor-T ype Rotary Reciprocating Scroll Air Coil-T ype Enhanced Copper tubes, Enhanced Aluminum Fins Face Area(sq ft) 1.17 1.17 ...

  • York YK145.00-EG4 - page 7

    Johnson Controls 7 W ater Source Heat Pumps T echnical Guide: YK145.00-EG4 (309) ARI/ISO PERFORMANCE D A T A PERFORMANCE D A T A - ARI/ISO 13256-1 WA TER LOOP CONDITIONS* Unit Model Flow Rate (USGPM) Air Flow (SCFM) Cooling Capacity (Btuh) EER Heating Capacity (Btuh) COP 007 1.8 260 6,800 12.5 8,700 4.5 009 2.4 320 8,900 12.4 1 1,600 4.4 012 3.0 40 ...

  • York YK145.00-EG4 - page 8

    8 Johnson Controls T echnical Guide: YK145.00-EG4 (309) W ater Source Heat Pumps PERFORMANCE D A T A RS*007 — 320 CFM EWT (F) GPM WPD COOLING HEA TING PSI FT TC SC kW HR EER HTG kW HE LA T (F) COP 20 1.8 4.8 1 1.0 4.1 0.44 2.6 80 2.7 30 1.0 2.1 4.9 8.5 6.0 0.30 9.5 28.0 5.0 0.45 3.5 82 3.3 1.4 2.8 6.4 8.7 6.1 0.28 9.7 30.8 5.3 0.47 3.7 83 3.3 1.8 ...

  • York YK145.00-EG4 - page 9

    Johnson Controls 9 W ater Source Heat Pumps T echnical Guide: YK145.00-EG4 (309) PERFORMANCE D A T A RS*009 — 320 CFM EWT (F) GPM WPD COOLING HEA TING PSI FT TC SC kW HR EER HTG kW HE LA T (F) COP 20 2.4 7.0 16.1 5.6 0.57 3.7 84 2.9 30 1.2 2.6 6.0 12.8 9.0 0.47 14.4 27.4 6.1 0.74 3.6 86 2.4 1.8 4.1 9.6 13.1 9.1 0.43 14.6 30.6 6.6 0.72 4.2 87 2.7 ...

  • York YK145.00-EG4 - page 10

    10 Johnson Controls T echnical Guide: YK145.00-EG4 (309) W ater Source Heat Pumps PERFORMANCE D A T A RS*012 — 400 CFM EWT (F) GPM WPD COOLING HEA TING PSI FT TC SC kW HR EER HTG kW HE LA T (F) COP 20 3.0 3.9 9.0 8.2 0.86 5.3 87 2.8 30 1.5 2.0 4.5 16.9 1 1.8 0.53 18.7 32.0 9.0 0.91 5.9 89 2.9 2.3 2.6 6.1 17.1 1 1.9 0.49 18.8 34.7 9.5 0.93 6.3 90 ...

  • York YK145.00-EG4 - page 11

    Johnson Controls 11 W ater Source Heat Pumps T echnical Guide: YK145.00-EG4 (309) PERFORMANCE D A T A RS*018 — 640 CFM EWT (F) GPM WPD COOLING HEA TING PSI FT TC SC kW HR EER HTG kW HE LA T (F) COP 20 4.8 8.4 19.4 10.4 1.09 6.7 83 2.8 30 2.4 3.1 7.1 26.6 18.6 0.96 29.9 27.7 12.0 1.17 8.0 85 3.0 3.6 4.9 1 1.3 27.3 19.1 0.90 30.4 30.2 12.4 1.21 8.3 ...

  • York YK145.00-EG4 - page 12

    12 Johnson Controls T echnical Guide: YK145.00-EG4 (309) W ater Source Heat Pumps PERFORMANCE D A T A RS*024 — 800 CFM EWT (F) GPM WPD COOLING HEA TING PSI FT TC SC kW HR EER HTG kW HE LA T (F) COP 20 6.0 9.7 22.4 13.3 1.50 8.2 83 2.6 30 3.0 3.4 7.9 35.1 24.6 1.07 38.8 32.7 15.9 1.50 10.8 86 3.1 4.5 5.2 12.0 35.9 25.0 1.01 39.4 35.4 16.4 1.50 1 1 ...

  • York YK145.00-EG4 - page 13

    Johnson Controls 13 W ater Source Heat Pumps T echnical Guide: YK145.00-EG4 (309) PERFORMANCE D A T A RS*030 — 1000 CFM EWT (F) GPM WPD COOLING HEA TING PSI FT TC SC kW HR EER HTG kW HE LA T (F) COP 20 7.8 7.8 18.0 17.5 1.97 10.8 84 2.6 30 3.9 4.2 9.8 38.6 27.0 1.43 43.5 26.9 19.2 1.88 12.8 86 3.0 5.8 5.4 12.4 39.5 27.5 1.41 44.3 28.0 20.3 1.92 1 ...

  • York YK145.00-EG4 - page 14

    14 Johnson Controls T echnical Guide: YK145.00-EG4 (309) W ater Source Heat Pumps PERFORMANCE D A T A RS*036 — 1200 CFM EWT (F) GPM WPD COOLING HEA TING PSI FT TC SC kW HR EER HTG kW HE LA T (F) COP 20 9.0 10.1 23.3 19.9 1.94 2.0 83 3.0 30 4.5 3.4 7.9 45.6 31.9 1.27 49.9 35.9 23.2 2.06 16.2 86 3.3 6.8 6.3 14.6 47.5 33.1 1.26 51.8 37.8 24.0 2.13 1 ...

  • York YK145.00-EG4 - page 15

    Johnson Controls 15 W ater Source Heat Pumps T echnical Guide: YK145.00-EG4 (309) PERFORMANCE D A T A RS*042 — 1400 CFM EWT (F) GPM WPD COOLING HEA TING PSI FT TC SC kW HR EER HTG kW HE LA T (F) COP 20 10.4 12.3 28.4 26.7 3.32 15.4 86 2.5 30 5.2 4.1 9.4 48.6 34.0 1.97 55.3 24.7 31.2 3.30 19.9 89 2.8 7.8 6.7 15.4 49.1 34.2 1.86 55.4 26.4 31.9 3.31 ...

  • York YK145.00-EG4 - page 16

    16 Johnson Controls T echnical Guide: YK145.00-EG4 (309) W ater Source Heat Pumps PERFORMANCE D A T A RS*048 — 1600 CFM EWT (F) GPM WPD COOLING HEA TING PSI FT TC SC kW HR EER HTG kW HE LA T (F) COP 20 12.0 15.1 34.9 30.5 3.32 19.1 86 2.8 30 6.0 4.4 10.1 61.3 42.9 2.33 69.3 26.3 33.4 3.30 3.3 88 3.0 9.0 8.5 19.5 62.2 43.4 2.29 70.0 27.2 35.6 3.32 ...

  • York YK145.00-EG4 - page 17

    Johnson Controls 17 W ater Source Heat Pumps T echnical Guide: YK145.00-EG4 (309) PERFORMANCE D A T A RS*060 — 2000 CFM EWT (F) GPM WPD COOLING HEA TING PSI FT TC SC kW HR EER HTG kW HE LA T (F) COP 20 15.0 17.8 41.1 38.2 3.32 26.8 86 2.9 30 7.5 5.9 13.5 72.6 50.8 2.77 82.1 26.2 43.2 3.90 29.9 88 3.2 1 1.2 7.5 17.3 73.8 51.4 2.60 82.7 28.4 45.2 3 ...

  • York YK145.00-EG4 - page 18

    18 Johnson Controls T echnical Guide: YK145.00-EG4 (309) W ater Source Heat Pumps PERFORMANCE D A T A RS*070 — 2200 CFM EWT (F) GPM WPD COOLING HEA TING PSI FT TC SC kW HR EER HTG kW HE LA T (F) COP 20 17.5 20.8 48.0 42.1 3.32 30.7 86 2.6 30 8.8 8.3 19.1 82.7 57.9 3.22 93.7 25.7 47.9 4.86 31.3 88 2.9 13.1 12.5 28.9 83.4 58.1 3.14 94.1 26.6 49.4 4 ...

  • York YK145.00-EG4 - page 19

    Johnson Controls 19 W ater Source Heat Pumps T echnical Guide: YK145.00-EG4 (309) CORRECTION F ACT ORS ANTIFREEZE CORRECTION T ABLE Antifreeze Concentration 5% 10% 15% 20% 25% 30% 40% Ethylene Glycol Cooling 0.998 0.995 0.993 0.991 0.989 0.987 0.984 Heating 0.995 0.990 0.985 0.980 0.974 0.969 0.964 PD 1.040 1.055 1.080 1.105 1.135 1.165 1.210 Propy ...

  • York YK145.00-EG4 - page 20

    20 Johnson Controls T echnical Guide: YK145.00-EG4 (309) W ater Source Heat Pumps BL O WER PERFORMANCE BLO WER PERFORMANCE Unit Size Rated CFM Min. CFM Max. CFM Motor Speed External Static Pressure (in w .g.) 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 007 260 182 299 High - - - - - - - - - Med - - 300 270 235 200 - - - Low 275 260 240 210 180 - - - - 009 32 ...

  • York YK145.00-EG4 - page 21

    Johnson Controls 21 W ater Source Heat Pumps T echnical Guide: YK145.00-EG4 (309) ELECTRICAL D A T A RSH/RSV ELECTRICAL D A T A Unit Size SUPPL Y VOL T AGE COMPRESSOR BLOWER MIN. CCT . AMP ACITY MAX FUSE / CCT . BKR. AMP QTY RLA LRA HP FLA 007 208-230/1/60 1 @ 3.4 22.0 0.10 0.8 5.05 15 009 208-230/1/60 1 @ 4.6 28.0 0.10 0.8 6.55 15 012 208-230/1/60 ...

  • York YK145.00-EG4 - page 22

    22 Johnson Controls T echnical Guide: YK145.00-EG4 (309) W ater Source Heat Pumps D A B E C G 1.50" J 2.00" K L 1.63" M 3/4 FPT DRAIN W A TER IN W A TER OUT SUPPL Y AIR AIR RETURN 0.75" TYP 0.75" Ø0.875" 1 2 3 3 - BLOWER SERVICE DOOR 2 - COMPRESSOR AND C ONDENSER 1 - ELECTRICAL BOX SERVICE DOOR SERVICE DOORS SERVICE D ...

  • York YK145.00-EG4 - page 23

    Johnson Controls 23 W ater Source Heat Pumps T echnical Guide: YK145.00-EG4 (309) A C K L 2 1" G D G F E G D G F E SERVICE DOORS 1 - ELECTRICAL BOX SERVICE DOOR 2 - COMPRESSOR AND C ONDENSER SERVICE DOOR 3 - BL OWER SER VICE DOOR B 2" AIR SUPPL Y RETURN AIR 1 3 W A TER IN W A TER OUT DRAIN 3/4Ø POWER CONNECTION LOW VOL T AGE CONNECTION B ...

  • York YK145.00-EG4 - page 24

    24 Johnson Controls T echnical Guide: YK145.00-EG4 (309) W ater Source Heat Pumps WIRING DIA GRAM SINGLE PHASE RS* UNITS: 208-230V/1Ph/60Hz 265V/1PH/60Hz ...

  • York YK145.00-EG4 - page 25

    Johnson Controls 25 W ater Source Heat Pumps T echnical Guide: YK145.00-EG4 (309) WIRING DIA GRAM 3 PHASE RS* UNITS: 208-230V/3Ph/60Hz 460V/3Ph/60Hz 575V/3Ph/60Hz ...

  • York YK145.00-EG4 - page 26

    26 Johnson Controls T echnical Guide: YK145.00-EG4 (309) W ater Source Heat Pumps NO TES ...

  • York YK145.00-EG4 - page 27

    Johnson Controls 27 W ater Source Heat Pumps T echnical Guide: YK145.00-EG4 (309) NO TES ...

  • York YK145.00-EG4 - page 28

    Printed on recycled paper T echnical Guide: YK145.00-EG4 (309) Supersedes: Nothing © 2008 Johnson Controls, Inc. P .O. Box 423, Milwaukee, WI 53201 Printed in USA www .johnsoncontrols.com ...

Fabbricante York Categoria Heat Pump

I documenti che otteniamo dal fabbricante del dispositivoYork YK145.00-EG4 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici York
- manuali per l’uso YK145.00-EG4
- schede prodotto York
- opuscoli
- o etichette energetiche York YK145.00-EG4
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso York YK145.00-EG4.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione York YK145.00-EG4, manuali di manutenzione, brevi manuali o manuali utente York YK145.00-EG4. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto York YK145.00-EG4.

Manuali per l’uso simili

Manuale completo del dispositivo York YK145.00-EG4, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare York YK145.00-EG4 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti York YK145.00-EG4.

Il manuale per l’uso completo York, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale York YK145.00-EG4 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice York YK145.00-EG4, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per York YK145.00-EG4 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo York YK145.00-EG4 - che ci dovrebbe aiutare nei primi passi durante l'uso York YK145.00-EG4
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del York YK145.00-EG4
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio York YK145.00-EG4 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su York YK145.00-EG4?

Utilizza il modulo sottostante

Se non hai risolto il problema con York YK145.00-EG4 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con York YK145.00-EG4 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)