    Ventless Hood System MODEL FH-28 Installation & Operation Manual Serial Numbers 123046 and higher ...

  • BKI Ventless Hood System FH-28 - page 2

    Warranty Information LIMITED ONE YEAR WARRANTY BKI (The "Company") warrants to the origin al purc haser that at time of shipment from the Company factory, this equipment will be free from defect in materials and workmanship. Written notice of a claim under this wa rranty must be receiv ed by the Company within ONE YEAR from the date of in ...

  • BKI Ventless Hood System FH-28 - page 3

    Ventless Hood System Table of Contents 1 T able of Content s Table of Contents .............................................................................................................. .......................... 1 Introduc tion ................................................................................................................... . ...

  • BKI Ventless Hood System FH-28 - page 4

    Ventless Hood System Introduction 2 Introduction Congratulations! You have cho sen BKI ’s Ventless Ho od syste m, a state-of-t he-a rt unit that filters g rease laden air and returns it to the room. The BKI name and trademark on this un it assures you of the finest in design and engineeri ng -- that it has been built with care and dedication -- u ...

  • BKI Ventless Hood System FH-28 - page 5

    Ventless Hood System Introduction 3 Specific Precautions Carbon monoxide poisoning will result from usin g this hood with a ny appliance that utilizes combustible fuel. Use only electrical appliances with this hood. In the event of an appliance fire, seriou s injury, property damage or death could occur if the appliance is not prope rly se cured to ...

  • BKI Ventless Hood System FH-28 - page 6

    Ventless Hood System Introduction 4 Keep Safety Labels Clean and in Good Condition Do not remove or cover any safety labels on your e quipment. Keep all safety labels clean and in good con dition. Replace any damaged or missing safety labels. If you need new safety labels, contact: BKI Technical Services Depart ment P.O. Box 80400 Simpsonville, S.C ...

  • BKI Ventless Hood System FH-28 - page 7

    Ventless Hood System Introduction 5 UL Information Failure to adhere to building, fire and electri cal co de s during installation of this unit could result in death, serio us inju ry or property damage. The authority having jurisdiction, such as the local buildi ng inspector or fire marshal, should be consulted prior to installation to insu re com ...

  • BKI Ventless Hood System FH-28 - page 8

    Ventless Hood System Introduction 6 Fryers Specifications Volts 208/240 Phase 1 or 3 Maximum Amps 60 Maximum Input 22 KW (3ph) 14.4 KW (1ph) Frequency 60 Hz Maximum normal frying temperature 375 ° F. (191 ° C.) Maximum shortening capacity 110 lbs. (50kg.) Maximum cooking surface area 396 sq. in. (2555 sq. cm.) USE ELECTRIC FRYERS AND SINGLE VAT F ...

  • BKI Ventless Hood System FH-28 - page 9

    Ventless Hood System Operation 7 Operation Principle of Operation A blower inside the ventless hood d raws cooking vap ors through a grease baffle. Inside the b affle, the air reverses direction two times capturing p article s of moisture, grease, and dirt. Material colle ctin g on the baffle drains into the condensation troug h locate d below the ...

  • BKI Ventless Hood System FH-28 - page 10

    Ventless Hood System Operation 8 Shut-Down Power to the appliance is turned off, when the hood is turned off. For proper operation, alwa ys turn off ap pliance and allow time for it to cool before turning off the filter hood. This will in sure proper capture of gre ase vapors. To stop the Filter Hood, press the “STOP ” button. When to Replace t ...

  • BKI Ventless Hood System FH-28 - page 11

    Ventless Hood System Installation 9 Inst allation Unpacking and Handling Inspection for Sh ipping Damage YOU are responsible for filing all freight claim s with th e delivering truck line. Insp ect all cartons and crate s for damage as soon as they arrive. If damage to ca rto ns or pallets is found, or if a shortage is found, note this on the bill ...

  • BKI Ventless Hood System FH-28 - page 12

    Ventless Hood System Installation 10 Leveling 1. Adjust the four feet provided on the bottom of the unit so there is a minimum of 6” clearance below the frame side members (NSF/UL REQUI REMENTS). 2. Check for level from side to side and front to back u si ng a 4’ level placed appropriately on the frame. ...

  • BKI Ventless Hood System FH-28 - page 13

    Ventless Hood System Installation 11 Securing Wall Mount After the hood has been located and lev eled, secure to building by utilizing the .4 37 diameter holes provided in the rear of the fire extinguisher cylinder sh elf (Refer to figure below). Usi ng 1/4” lag screw(s), spacer(s) (if required), and anchor(s) (if requi red) secure the hood to a ...

  • BKI Ventless Hood System FH-28 - page 14

    Ventless Hood System Installation 12 Assembly and Mounting Fire Damper A UL Listed 165 ° F fusible link must be installed in the dampe r assembly locate d at the top of the unit. Install as follows: 1. Lift the damper. 2. Place the link on the damper hook. 3. Lower the damper while placin g the link onto the stati onary hook. Air Deflector Mount a ...

  • BKI Ventless Hood System FH-28 - page 15

    Ventless Hood System Installation 13 Particle/Odor Filter 1. Remove the filter from the plastic bag. 2. Open the filter door on the front of the unit by rotating the handle counter-clockwise. 3. Observing the “UP” arrows on the filter, with a hand at each front corne r, carefully slide the filter into the unit. 4. Close and latch the door. Appl ...

  • BKI Ventless Hood System FH-28 - page 16

    Ventless Hood System Installation 14 Appliance Restraining Device Install appliance-restraining device as shown in the figure bel ow. In the event of an appliance fire, seriou s injury, property damage or death could occur if the appliance is not secu red to t he hood. A restraining devi ce ha s be en provided to assure that the cooking appliance r ...

  • BKI Ventless Hood System FH-28 - page 17

    Ventless Hood System Installation 15 Fire Extinguishi ng Sy stem In the event of an appliance fire, seriou s injury, property damage or death could occur if any part of the appliance obstructs the spray n ozzles. Ensure that lids and/or other parts of the appliance do n o t obstruct the spray pattern of either nozzle. The fire extinguishing system ...

  • BKI Ventless Hood System FH-28 - page 18

    Ventless Hood System Installation 16 3. If required, connect the provided fire extingui shing system contacts for remote signaling (refe r to the electrical diagram in this manual). 4. Adjust the position of the two ADP appliance nozzl es as depicted b elow. 5. Reset control head. With control he ad NOT co nnect ed to cylinder, dry test system by a ...

  • BKI Ventless Hood System FH-28 - page 19

    Ventless Hood System Installation 17 The fire extinguishing system must be o perative before the electrical system will function. Refer to the electrical diagram included i n attached to this unit or in the servi ce manual. Standard Electrical Connection This connection is for UL listed ap pliances supplied wi th a cord and a NEMA style 15-60 right ...

  • BKI Ventless Hood System FH-28 - page 20

    Ventless Hood System Installation 18 ...

  • BKI Ventless Hood System FH-28 - page 21

    Ventless Hood System Installation 19 Appliance Electrical Connection This connection is for ap pli ances requiring a UL listed flexible conduit connections (refer to figure below). 1. Remove receptacle and fo ur wires (T1, T2, T3, and Grou nd). 2. Cover junction box hole with provided pl ate and hardware removed from re ceptacle. 3. Remove hole plu ...

  • BKI Ventless Hood System FH-28 - page 22

    Ventless Hood System Maintenance 20 Maintenance Electrocution could occur if this unit is hosed d own wit h water. This unit is NOT designed for hose wash -d own cleaning! Refer to sch eduled maintenance b elow for proper hood cleaning. Electrocution could occur if powe r is not removed from this unit before servicing. Remove power at disconnect or ...

  • BKI Ventless Hood System FH-28 - page 23

    Ventless Hood System Maintenance 21 Cleaning the Grease Baffle 1. Shut down the unit. 2. Locate the thumbscrews and retaining fr ame at the top of the grea se baffle. 3. With one hand, hold the baffle to prevent it from dropping. With the other hand, lo ose n the thumbscrews and slide the retaining frame forward. 4. Slowly lower the top end of the ...

  • BKI Ventless Hood System FH-28 - page 24

    P.O. Box 80400, Simpsonvill e, S.C. 29680-0400, USA http://www.bkideas.co m Made and printed in t he U.S.A LI0114/0 407 ...

Fabbricante BKI Categoria Ventilation Hood

I documenti che otteniamo dal fabbricante del dispositivoBKI Ventless Hood System FH-28 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici BKI
- manuali per l’uso Ventless Hood System FH-28
- schede prodotto BKI
- opuscoli
- o etichette energetiche BKI Ventless Hood System FH-28
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso BKI Ventless Hood System FH-28.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione BKI Ventless Hood System FH-28, manuali di manutenzione, brevi manuali o manuali utente BKI Ventless Hood System FH-28. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto BKI Ventless Hood System FH-28.

Manuali per l’uso simili

Manuale completo del dispositivo BKI Ventless Hood System FH-28, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare BKI Ventless Hood System FH-28 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti BKI Ventless Hood System FH-28.

Il manuale per l’uso completo BKI, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale BKI Ventless Hood System FH-28 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice BKI Ventless Hood System FH-28, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per BKI Ventless Hood System FH-28 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo BKI Ventless Hood System FH-28 - che ci dovrebbe aiutare nei primi passi durante l'uso BKI Ventless Hood System FH-28
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del BKI Ventless Hood System FH-28
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio BKI Ventless Hood System FH-28 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su BKI Ventless Hood System FH-28?

Utilizza il modulo sottostante

Se non hai risolto il problema con BKI Ventless Hood System FH-28 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con BKI Ventless Hood System FH-28 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)