BKI Ventless Hood System FH-28の取扱説明書

24ページ 2.13 mb
ダウンロード

ページに移動 of 24

Summary
  • BKI Ventless Hood System FH-28 - page 1

    Ventless Hood System MODEL FH-28 Installation & Operation Manual Serial Numbers 123046 and higher ...

  • BKI Ventless Hood System FH-28 - page 2

    Warranty Information LIMITED ONE YEAR WARRANTY BKI (The "Company") warrants to the origin al purc haser that at time of shipment from the Company factory, this equipment will be free from defect in materials and workmanship. Written notice of a claim under this wa rranty must be receiv ed by the Company within ONE YEAR from the date of in ...

  • BKI Ventless Hood System FH-28 - page 3

    Ventless Hood System Table of Contents 1 T able of Content s Table of Contents .............................................................................................................. .......................... 1 Introduc tion ................................................................................................................... . ...

  • BKI Ventless Hood System FH-28 - page 4

    Ventless Hood System Introduction 2 Introduction Congratulations! You have cho sen BKI ’s Ventless Ho od syste m, a state-of-t he-a rt unit that filters g rease laden air and returns it to the room. The BKI name and trademark on this un it assures you of the finest in design and engineeri ng -- that it has been built with care and dedication -- u ...

  • BKI Ventless Hood System FH-28 - page 5

    Ventless Hood System Introduction 3 Specific Precautions Carbon monoxide poisoning will result from usin g this hood with a ny appliance that utilizes combustible fuel. Use only electrical appliances with this hood. In the event of an appliance fire, seriou s injury, property damage or death could occur if the appliance is not prope rly se cured to ...

  • BKI Ventless Hood System FH-28 - page 6

    Ventless Hood System Introduction 4 Keep Safety Labels Clean and in Good Condition Do not remove or cover any safety labels on your e quipment. Keep all safety labels clean and in good con dition. Replace any damaged or missing safety labels. If you need new safety labels, contact: BKI Technical Services Depart ment P.O. Box 80400 Simpsonville, S.C ...

  • BKI Ventless Hood System FH-28 - page 7

    Ventless Hood System Introduction 5 UL Information Failure to adhere to building, fire and electri cal co de s during installation of this unit could result in death, serio us inju ry or property damage. The authority having jurisdiction, such as the local buildi ng inspector or fire marshal, should be consulted prior to installation to insu re com ...

  • BKI Ventless Hood System FH-28 - page 8

    Ventless Hood System Introduction 6 Fryers Specifications Volts 208/240 Phase 1 or 3 Maximum Amps 60 Maximum Input 22 KW (3ph) 14.4 KW (1ph) Frequency 60 Hz Maximum normal frying temperature 375 ° F. (191 ° C.) Maximum shortening capacity 110 lbs. (50kg.) Maximum cooking surface area 396 sq. in. (2555 sq. cm.) USE ELECTRIC FRYERS AND SINGLE VAT F ...

  • BKI Ventless Hood System FH-28 - page 9

    Ventless Hood System Operation 7 Operation Principle of Operation A blower inside the ventless hood d raws cooking vap ors through a grease baffle. Inside the b affle, the air reverses direction two times capturing p article s of moisture, grease, and dirt. Material colle ctin g on the baffle drains into the condensation troug h locate d below the ...

  • BKI Ventless Hood System FH-28 - page 10

    Ventless Hood System Operation 8 Shut-Down Power to the appliance is turned off, when the hood is turned off. For proper operation, alwa ys turn off ap pliance and allow time for it to cool before turning off the filter hood. This will in sure proper capture of gre ase vapors. To stop the Filter Hood, press the “STOP ” button. When to Replace t ...

  • BKI Ventless Hood System FH-28 - page 11

    Ventless Hood System Installation 9 Inst allation Unpacking and Handling Inspection for Sh ipping Damage YOU are responsible for filing all freight claim s with th e delivering truck line. Insp ect all cartons and crate s for damage as soon as they arrive. If damage to ca rto ns or pallets is found, or if a shortage is found, note this on the bill ...

  • BKI Ventless Hood System FH-28 - page 12

    Ventless Hood System Installation 10 Leveling 1. Adjust the four feet provided on the bottom of the unit so there is a minimum of 6” clearance below the frame side members (NSF/UL REQUI REMENTS). 2. Check for level from side to side and front to back u si ng a 4’ level placed appropriately on the frame. ...

  • BKI Ventless Hood System FH-28 - page 13

    Ventless Hood System Installation 11 Securing Wall Mount After the hood has been located and lev eled, secure to building by utilizing the .4 37 diameter holes provided in the rear of the fire extinguisher cylinder sh elf (Refer to figure below). Usi ng 1/4” lag screw(s), spacer(s) (if required), and anchor(s) (if requi red) secure the hood to a ...

  • BKI Ventless Hood System FH-28 - page 14

    Ventless Hood System Installation 12 Assembly and Mounting Fire Damper A UL Listed 165 ° F fusible link must be installed in the dampe r assembly locate d at the top of the unit. Install as follows: 1. Lift the damper. 2. Place the link on the damper hook. 3. Lower the damper while placin g the link onto the stati onary hook. Air Deflector Mount a ...

  • BKI Ventless Hood System FH-28 - page 15

    Ventless Hood System Installation 13 Particle/Odor Filter 1. Remove the filter from the plastic bag. 2. Open the filter door on the front of the unit by rotating the handle counter-clockwise. 3. Observing the “UP” arrows on the filter, with a hand at each front corne r, carefully slide the filter into the unit. 4. Close and latch the door. Appl ...

  • BKI Ventless Hood System FH-28 - page 16

    Ventless Hood System Installation 14 Appliance Restraining Device Install appliance-restraining device as shown in the figure bel ow. In the event of an appliance fire, seriou s injury, property damage or death could occur if the appliance is not secu red to t he hood. A restraining devi ce ha s be en provided to assure that the cooking appliance r ...

  • BKI Ventless Hood System FH-28 - page 17

    Ventless Hood System Installation 15 Fire Extinguishi ng Sy stem In the event of an appliance fire, seriou s injury, property damage or death could occur if any part of the appliance obstructs the spray n ozzles. Ensure that lids and/or other parts of the appliance do n o t obstruct the spray pattern of either nozzle. The fire extinguishing system ...

  • BKI Ventless Hood System FH-28 - page 18

    Ventless Hood System Installation 16 3. If required, connect the provided fire extingui shing system contacts for remote signaling (refe r to the electrical diagram in this manual). 4. Adjust the position of the two ADP appliance nozzl es as depicted b elow. 5. Reset control head. With control he ad NOT co nnect ed to cylinder, dry test system by a ...

  • BKI Ventless Hood System FH-28 - page 19

    Ventless Hood System Installation 17 The fire extinguishing system must be o perative before the electrical system will function. Refer to the electrical diagram included i n attached to this unit or in the servi ce manual. Standard Electrical Connection This connection is for UL listed ap pliances supplied wi th a cord and a NEMA style 15-60 right ...

  • BKI Ventless Hood System FH-28 - page 20

    Ventless Hood System Installation 18 ...

  • BKI Ventless Hood System FH-28 - page 21

    Ventless Hood System Installation 19 Appliance Electrical Connection This connection is for ap pli ances requiring a UL listed flexible conduit connections (refer to figure below). 1. Remove receptacle and fo ur wires (T1, T2, T3, and Grou nd). 2. Cover junction box hole with provided pl ate and hardware removed from re ceptacle. 3. Remove hole plu ...

  • BKI Ventless Hood System FH-28 - page 22

    Ventless Hood System Maintenance 20 Maintenance Electrocution could occur if this unit is hosed d own wit h water. This unit is NOT designed for hose wash -d own cleaning! Refer to sch eduled maintenance b elow for proper hood cleaning. Electrocution could occur if powe r is not removed from this unit before servicing. Remove power at disconnect or ...

  • BKI Ventless Hood System FH-28 - page 23

    Ventless Hood System Maintenance 21 Cleaning the Grease Baffle 1. Shut down the unit. 2. Locate the thumbscrews and retaining fr ame at the top of the grea se baffle. 3. With one hand, hold the baffle to prevent it from dropping. With the other hand, lo ose n the thumbscrews and slide the retaining frame forward. 4. Slowly lower the top end of the ...

  • BKI Ventless Hood System FH-28 - page 24

    P.O. Box 80400, Simpsonvill e, S.C. 29680-0400, USA http://www.bkideas.co m Made and printed in t he U.S.A LI0114/0 407 ...

メーカー BKI カテゴリー Ventilation Hood

BKI Ventless Hood System FH-28のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- Ventless Hood System FH-28の取扱説明書
- BKIの製品カード
- パンフレット
- またはBKI Ventless Hood System FH-28の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、BKI Ventless Hood System FH-28の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、BKI Ventless Hood System FH-28の取り付け説明書、サービスマニュアル、簡易説明書、またはBKI Ventless Hood System FH-28のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、BKI Ventless Hood System FH-28の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

BKI Ventless Hood System FH-28デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBKI Ventless Hood System FH-28を使用するのを助ける技術的文書のことです。説明書は通常、全てのBKI Ventless Hood System FH-28ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

BKIの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. BKI Ventless Hood System FH-28の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBKI Ventless Hood System FH-28の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。BKI Ventless Hood System FH-28に関してこのドキュメントで見つけることができる全てのヒントの目次
3. BKI Ventless Hood System FH-28デバイスの基本機能を使うにあたってのヒント。 BKI Ventless Hood System FH-28のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。BKI Ventless Hood System FH-28に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBKI Ventless Hood System FH-28のメーカー/サービスへの連絡先に関する情報。

BKI Ventless Hood System FH-28についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBKI Ventless Hood System FH-28の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBKI Ventless Hood System FH-28で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)