  • Emerson TG-0807 - page 1

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 www .daniel.com Daniel ® Liquid T urbine Flow Meter T echnical Guide Liquid T urbine Flow Met ers ...

  • Emerson TG-0807 - page 2

    ...

  • Emerson TG-0807 - page 3

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 T ABLE OF CONTENTS T urbine Meter Parameters ............................................................................................................................. 1 The Daniel Series 1200 and 1500 Liquid T urbine Flow Meter Systems .................................................. ...

  • Emerson TG-0807 - page 4

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 1 +0.15% –0.15% +0.02% –0.02% TURBINE METER P ARAMETERS These ve terms are the most widely discussed parameters of turbine meter applications. Linearity is the measure of variation in signal output across the nominal ow range of the meter . The turbine meter will have a nomi ...

  • Emerson TG-0807 - page 5

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 2 THE DANIEL ® SERIES 1200 AND 1500 LIQUID TURBINE FLOW METER SYSTEMS The Daniel Series 1200 and 1500 Liquid T urbine Flow Meter Systems combine turbine meters and electronic instrumentation to measure volumetric total ow and/or ow rate. Each Daniel turbine meter comprises of a ...

  • Emerson TG-0807 - page 6

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 3 Daniel ® V alves In Load Rack Duty TURBINE METER THEOR Y The basic theory behind Daniel’s electronic liquid turbine meters is relatively simple. Fluid ow through the meter impinges upon the turbine blades which are free to rotate about an axis along the center line of the turb ...

  • Emerson TG-0807 - page 7

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 4 P A TENTED* FLOA TING ROT OR Flowing uid enters the turbine through the forward suspension. When it encounters the sharp angle of the cone, the stream is deected outward, increasing in velocity and causing a slight static pressure drop. As the uid leaves the blade area,  ...

  • Emerson TG-0807 - page 8

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 5 Surge And Pressure Relief V alves MAGNETIC PICKOFF OF ROTOR VELOCITY The angular velocity of the turbine rotor is taken through the turbine meter wall by means of a magnetic pickoff. The stainless steel meter body is non-magnetic and offers negligible ef fect on a magnetic eld se ...

  • Emerson TG-0807 - page 9

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 6 TURBINE METER ROTOR AND BEARING DESIGN The primary differences in turbine meter technology are in the design of the rotor and bearings. The rotor is an assembly of up to twelve (in some designs this number is greater) blades locked into a hub, which rotates on a bearing or bearings. ...

  • Emerson TG-0807 - page 10

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 7 RIMMED ROTORS FOR HIGHER RESOLUTION In the larger diameter Daniel Series 1500 Liquid T urbine Flow Meter (normally above 6” in line size), the resolution provided by a blade-type motor may be improved by the use of a rimmed (or shrouded) rotor . This construction is standard for D ...

  • Emerson TG-0807 - page 11

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 8 DANIEL ® SERIES 1200 LIQUID TURBINE FLOW METER Daniel Series 1200 Liquid T urbine Flow Meters are designed specically for load rack service where a vital characteristic is repeatability . The meter deploys a lightweight rotor which is supported on self-cleaning ow through bal ...

  • Emerson TG-0807 - page 12

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 9 DANIEL ® SERIES 1200 LIQUID TURBINE FLOW METER DESIGN FEA TURES The following data is applicable for Daniel Series 1200 Liquid T urbine Flow Meter calibrated on mineral spirits. Size (Inches) Standard Flow Range Extended Flow Range Standard Flow Range Extended Flow Range Standard F ...

  • Emerson TG-0807 - page 13

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 10 DANIEL ® SERIES 1200 LIQUID TURBINE FLOW METER MA TERIALS OF CONSTRUCTION Standard Optional Body/Flanges 1” and 1.5” Stainless Steel NA 2” - 4” Carbon Steel 304 Stainless Steel Suspension Anodized Aluminum None Rotor Blades 400 Series Stainless Steel None Rotor Hub Aluminu ...

  • Emerson TG-0807 - page 14

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 1 1 DANIEL ® SERIES 1500 LIQUID TURBINE FLOW METER The Daniel Series 1500 Liquid T urbine Flow Meter is designed for applications requiring rugged dependability with high accuracy and throughput. Used on pipelines, marine loading and other demanding systems, the internals used are we ...

  • Emerson TG-0807 - page 15

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 12 The deployment of this high resolution rotor in each of the sizes available gives a nominal K-factor twice that of the standard meter and allows for proving with a smaller size prover . The rimmed design is available as an option on 3”-6” turbines, and is standard on 8” and l ...

  • Emerson TG-0807 - page 16

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 13 Item Standard Optional Optional Meter body and anges 304 Standard 1” and 1.5” NA 316 SS CS Standard 2” and up 304 SS 316 SS Suspension 304 SS 304 SS 316 SS Rotor Blades (Rim T ype) 304 SS 304 SS 316 SS Rotor Blades (Blades T ype) 430 SS 430 SS Nickel 200 Sleeve Bearings T ...

  • Emerson TG-0807 - page 17

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 14 RANGEABILITY OF LIQUID TURBINE FLOW METERS The ow ranges indicated in the previous tables show a nominal ow range -- with a turndown of 10:1 - at which the turbine will report measurement repeatable to the indicated specication based on measurement of clean liquids such as ...

  • Emerson TG-0807 - page 18

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 15 DANIEL ® SERIES 1500 LIQUID TURBINE FLOW METER SPECIFIC GRA VITY ADJUSTMENTS S.G. = 1 ( .7 to 1 ) Meter Size Minimum Linear Maximum Linear BBL/Hr M 3 /Hr USGPM BBL/Hr M 3 /Hr USGPM 1 10 1.59 7 100 15.90 70 1.5 21.4 3.40 15 214 34 150 2 35.7 5.68 25 357 56.76 250 2.5 57.1 9.08 40 5 ...

  • Emerson TG-0807 - page 19

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 16 METER PERFORMANCE IN HIGH VISCOSITY LIQUIDS Increases in viscosity of the measured liquid will reduce the rangeability of the ow meter . Generally , the minimum ow rate of the meter will have to be increased to maintain the linearity rating of the meter . The increased ow ...

  • Emerson TG-0807 - page 20

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 17 INST ALLA TION AND OPERA TING RECOMMENDA TIONS For a turbine meter to perform without increased uncertainty and in a repeatable and accurate manner , the owing stream must be free of rotational components. The internal assembly supports of a turbine meter of fer a slight straigh ...

  • Emerson TG-0807 - page 21

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 18 Figure 14 - Effects of Back Pressure In some circumstances, the use of a Flow Conditioning Plate (FCP) is possible. The ow conditioning plate is available from 3” to 6” for the Daniel Series 1500 Liquid T urbine Flow Meter , and is standard on the Daniel Series 1200 Liquid T ...

  • Emerson TG-0807 - page 22

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 19 DUAL CHANNEL PREAMP TERMINAL IDENTIFICA TION CUSTOMER CONNECTIONS BLACK OR RED PICKOFF PICKOFF WHITE WHITE CHANNEL B CHANNEL A BLACK OR RED T U P T U O B . A H C T U P T U O A . A H C C D V 0 3 O T 0 1 + N O M M O C N O M M O C TB1 1 2 3 4 5 2 1 2 1 TB2 TB3 J3 J4 J2 JUMPER POSITION ...

  • Emerson TG-0807 - page 23

    ...

  • Emerson TG-0807 - page 24

    Emerson Process Management Daniel Measurement and Control, Inc. World Area Headquarters Houston, T exas, USA T : 713 -46 7-6 00 0, F : 71 3-8 27- 38 80 US A T oll Fre e 1- 888 -F LOW -0 01 ww w .d an iel .co m Calgary , Alberta, Canada T : 403 -27 9-1 87 9, F : 40 3-2 36- 13 37 Al ber ta T o ll F ree 1-8 00- 24 2-3 197 Sa les @Da ni eli nd- ca n.c ...

Fabbricante Emerson Categoria Doll

I documenti che otteniamo dal fabbricante del dispositivoEmerson TG-0807 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Emerson
- manuali per l’uso TG-0807
- schede prodotto Emerson
- opuscoli
- o etichette energetiche Emerson TG-0807
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Emerson TG-0807.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Emerson TG-0807, manuali di manutenzione, brevi manuali o manuali utente Emerson TG-0807. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Emerson TG-0807.

Manuali per l’uso simili

Manuale completo del dispositivo Emerson TG-0807, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Emerson TG-0807 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Emerson TG-0807.

Il manuale per l’uso completo Emerson, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Emerson TG-0807 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Emerson TG-0807, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Emerson TG-0807 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Emerson TG-0807 - che ci dovrebbe aiutare nei primi passi durante l'uso Emerson TG-0807
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Emerson TG-0807
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Emerson TG-0807 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Emerson TG-0807?

Utilizza il modulo sottostante

Se non hai risolto il problema con Emerson TG-0807 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Emerson TG-0807 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)