  • Emerson TG-0807 - page 1

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 www .daniel.com Daniel ® Liquid T urbine Flow Meter T echnical Guide Liquid T urbine Flow Met ers ...

  • Emerson TG-0807 - page 2

    ...

  • Emerson TG-0807 - page 3

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 T ABLE OF CONTENTS T urbine Meter Parameters ............................................................................................................................. 1 The Daniel Series 1200 and 1500 Liquid T urbine Flow Meter Systems .................................................. ...

  • Emerson TG-0807 - page 4

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 1 +0.15% –0.15% +0.02% –0.02% TURBINE METER P ARAMETERS These ve terms are the most widely discussed parameters of turbine meter applications. Linearity is the measure of variation in signal output across the nominal ow range of the meter . The turbine meter will have a nomi ...

  • Emerson TG-0807 - page 5

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 2 THE DANIEL ® SERIES 1200 AND 1500 LIQUID TURBINE FLOW METER SYSTEMS The Daniel Series 1200 and 1500 Liquid T urbine Flow Meter Systems combine turbine meters and electronic instrumentation to measure volumetric total ow and/or ow rate. Each Daniel turbine meter comprises of a ...

  • Emerson TG-0807 - page 6

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 3 Daniel ® V alves In Load Rack Duty TURBINE METER THEOR Y The basic theory behind Daniel’s electronic liquid turbine meters is relatively simple. Fluid ow through the meter impinges upon the turbine blades which are free to rotate about an axis along the center line of the turb ...

  • Emerson TG-0807 - page 7

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 4 P A TENTED* FLOA TING ROT OR Flowing uid enters the turbine through the forward suspension. When it encounters the sharp angle of the cone, the stream is deected outward, increasing in velocity and causing a slight static pressure drop. As the uid leaves the blade area,  ...

  • Emerson TG-0807 - page 8

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 5 Surge And Pressure Relief V alves MAGNETIC PICKOFF OF ROTOR VELOCITY The angular velocity of the turbine rotor is taken through the turbine meter wall by means of a magnetic pickoff. The stainless steel meter body is non-magnetic and offers negligible ef fect on a magnetic eld se ...

  • Emerson TG-0807 - page 9

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 6 TURBINE METER ROTOR AND BEARING DESIGN The primary differences in turbine meter technology are in the design of the rotor and bearings. The rotor is an assembly of up to twelve (in some designs this number is greater) blades locked into a hub, which rotates on a bearing or bearings. ...

  • Emerson TG-0807 - page 10

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 7 RIMMED ROTORS FOR HIGHER RESOLUTION In the larger diameter Daniel Series 1500 Liquid T urbine Flow Meter (normally above 6” in line size), the resolution provided by a blade-type motor may be improved by the use of a rimmed (or shrouded) rotor . This construction is standard for D ...

  • Emerson TG-0807 - page 11

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 8 DANIEL ® SERIES 1200 LIQUID TURBINE FLOW METER Daniel Series 1200 Liquid T urbine Flow Meters are designed specically for load rack service where a vital characteristic is repeatability . The meter deploys a lightweight rotor which is supported on self-cleaning ow through bal ...

  • Emerson TG-0807 - page 12

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 9 DANIEL ® SERIES 1200 LIQUID TURBINE FLOW METER DESIGN FEA TURES The following data is applicable for Daniel Series 1200 Liquid T urbine Flow Meter calibrated on mineral spirits. Size (Inches) Standard Flow Range Extended Flow Range Standard Flow Range Extended Flow Range Standard F ...

  • Emerson TG-0807 - page 13

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 10 DANIEL ® SERIES 1200 LIQUID TURBINE FLOW METER MA TERIALS OF CONSTRUCTION Standard Optional Body/Flanges 1” and 1.5” Stainless Steel NA 2” - 4” Carbon Steel 304 Stainless Steel Suspension Anodized Aluminum None Rotor Blades 400 Series Stainless Steel None Rotor Hub Aluminu ...

  • Emerson TG-0807 - page 14

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 1 1 DANIEL ® SERIES 1500 LIQUID TURBINE FLOW METER The Daniel Series 1500 Liquid T urbine Flow Meter is designed for applications requiring rugged dependability with high accuracy and throughput. Used on pipelines, marine loading and other demanding systems, the internals used are we ...

  • Emerson TG-0807 - page 15

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 12 The deployment of this high resolution rotor in each of the sizes available gives a nominal K-factor twice that of the standard meter and allows for proving with a smaller size prover . The rimmed design is available as an option on 3”-6” turbines, and is standard on 8” and l ...

  • Emerson TG-0807 - page 16

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 13 Item Standard Optional Optional Meter body and anges 304 Standard 1” and 1.5” NA 316 SS CS Standard 2” and up 304 SS 316 SS Suspension 304 SS 304 SS 316 SS Rotor Blades (Rim T ype) 304 SS 304 SS 316 SS Rotor Blades (Blades T ype) 430 SS 430 SS Nickel 200 Sleeve Bearings T ...

  • Emerson TG-0807 - page 17

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 14 RANGEABILITY OF LIQUID TURBINE FLOW METERS The ow ranges indicated in the previous tables show a nominal ow range -- with a turndown of 10:1 - at which the turbine will report measurement repeatable to the indicated specication based on measurement of clean liquids such as ...

  • Emerson TG-0807 - page 18

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 15 DANIEL ® SERIES 1500 LIQUID TURBINE FLOW METER SPECIFIC GRA VITY ADJUSTMENTS S.G. = 1 ( .7 to 1 ) Meter Size Minimum Linear Maximum Linear BBL/Hr M 3 /Hr USGPM BBL/Hr M 3 /Hr USGPM 1 10 1.59 7 100 15.90 70 1.5 21.4 3.40 15 214 34 150 2 35.7 5.68 25 357 56.76 250 2.5 57.1 9.08 40 5 ...

  • Emerson TG-0807 - page 19

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 16 METER PERFORMANCE IN HIGH VISCOSITY LIQUIDS Increases in viscosity of the measured liquid will reduce the rangeability of the ow meter . Generally , the minimum ow rate of the meter will have to be increased to maintain the linearity rating of the meter . The increased ow ...

  • Emerson TG-0807 - page 20

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 17 INST ALLA TION AND OPERA TING RECOMMENDA TIONS For a turbine meter to perform without increased uncertainty and in a repeatable and accurate manner , the owing stream must be free of rotational components. The internal assembly supports of a turbine meter of fer a slight straigh ...

  • Emerson TG-0807 - page 21

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 18 Figure 14 - Effects of Back Pressure In some circumstances, the use of a Flow Conditioning Plate (FCP) is possible. The ow conditioning plate is available from 3” to 6” for the Daniel Series 1500 Liquid T urbine Flow Meter , and is standard on the Daniel Series 1200 Liquid T ...

  • Emerson TG-0807 - page 22

    T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 19 DUAL CHANNEL PREAMP TERMINAL IDENTIFICA TION CUSTOMER CONNECTIONS BLACK OR RED PICKOFF PICKOFF WHITE WHITE CHANNEL B CHANNEL A BLACK OR RED T U P T U O B . A H C T U P T U O A . A H C C D V 0 3 O T 0 1 + N O M M O C N O M M O C TB1 1 2 3 4 5 2 1 2 1 TB2 TB3 J3 J4 J2 JUMPER POSITION ...

  • Emerson TG-0807 - page 23

    ...

  • Emerson TG-0807 - page 24

    Emerson Process Management Daniel Measurement and Control, Inc. World Area Headquarters Houston, T exas, USA T : 713 -46 7-6 00 0, F : 71 3-8 27- 38 80 US A T oll Fre e 1- 888 -F LOW -0 01 ww w .d an iel .co m Calgary , Alberta, Canada T : 403 -27 9-1 87 9, F : 40 3-2 36- 13 37 Al ber ta T o ll F ree 1-8 00- 24 2-3 197 Sa les @Da ni eli nd- ca n.c ...

メーカー Emerson カテゴリー Doll

Emerson TG-0807のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- TG-0807の取扱説明書
- Emersonの製品カード
- パンフレット
- またはEmerson TG-0807の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Emerson TG-0807の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Emerson TG-0807の取り付け説明書、サービスマニュアル、簡易説明書、またはEmerson TG-0807のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Emerson TG-0807の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Emerson TG-0807デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがEmerson TG-0807を使用するのを助ける技術的文書のことです。説明書は通常、全てのEmerson TG-0807ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Emersonの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Emerson TG-0807の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははEmerson TG-0807の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Emerson TG-0807に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Emerson TG-0807デバイスの基本機能を使うにあたってのヒント。 Emerson TG-0807のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Emerson TG-0807に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるEmerson TG-0807のメーカー/サービスへの連絡先に関する情報。

Emerson TG-0807についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもEmerson TG-0807の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがEmerson TG-0807で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)