    PCI-2513 User's Guide Document Revision 3, June , 2007 © Copyright 2007, Measurement Com puting Corporati on ...

  • Measurement Specialties PCI-2513 - page 3

    3 HM PCI-2513.doc Your new Measurement Computing produc t comes with a fantastic extra — Management committed to your satisfaction! Refer to www.mccdaq.com/execteam.html for the names, titles, an d contact inform ation of each ke y executive at Measurement Computing. Thank you for choosing a Measurement Co mputing product— and congratulations! ...

  • Measurement Specialties PCI-2513 - page 4

    4 Trademark and Copyright Information TracerDAQ, Universal Library, Harsh E nvironment Warranty , Measurement Compu ting Corporation, an d the Measurement Computing logo are either trademarks or registered trademarks of M easurement C omputing Corporation. Windows, Microsoft, and Visual Studio ar e either trad emar ks or re gistered trademarks of M ...

  • Measurement Specialties PCI-2513 - page 5

    5 Table of Contents Preface About this U ser's Gu ide .......................................................................................................................7 What you will learn from this user's guide ..................................................................................... .................... 7 Conventions u ...

  • Measurement Specialties PCI-2513 - page 6

    PCI-2513 User's Guide 6 What are d etection setpoin ts? .................................................................................................. ........................................24 Setpoint configur ation overvi ew ................................................................................................ ................ ...

  • Measurement Specialties PCI-2513 - page 7

    7 Preface About this User's Guide What you will learn from this user's guide This user's guide explain s how to instal l, confi gure, and use t he PCI-2513 so t hat you get the most out of its analog input, digital I/O, and counter/timer I/O features. This user's guide also re fers you to related docum ents avail able on our we ...

  • Measurement Specialties PCI-2513 - page 8

    8 Chapter 1 Introducing the PCI-2513 Overview: PCI-2513 features The PCI-2513 is support ed under popul ar Microsoft ® Windows ® operating systems. The PCI-2513 provides either eight diff erential or 16 single-ended analog inputs with 16-bit resolution. It offers seven software -selectable analog input range s of ±10 V, ±5 V, ±2 V, ±1 V, ±0. ...

  • Measurement Specialties PCI-2513 - page 9

    9 Chapter 2 Installing the PCI-2513 What comes with your PCI-2513 shipment? As you unpack your PCI-251 3, verify that the followi ng compone nts are i ncluded. Hardware  PCI-2513 Optional components Cables and signal conditioning accessories that are comp atible with the PCI-2513 are not include d with PCI- 2513 orders , and must be ordered sepa ...

  • Measurement Specialties PCI-2513 - page 10

    PCI-2513 User's Guide Installing the PCI-2513 10 Additional documentation In addition to this hard ware user's guide, you shoul d also receive the Quick Start Guide (available in PDF at www.mccdaq.c om/PDFma nuals/DAQ -Software -Quick-Start.pdf ). This booklet supplies a brief description of the software you received wi th your PCI-2513 a ...

  • Measurement Specialties PCI-2513 - page 11

    PCI-2513 User's Guide Installing the PCI-2513 11 3. To test your installation and conf igure your board, run the Insta Cal utility installed in th e previous section. Refer to the Quick St art Gui de that came with your board for information on how to initially set up and load Insta Cal. If your boar d has been powered-of f for mor e than 10 m ...

  • Measurement Specialties PCI-2513 - page 12

    PCI-2513 User's Guide Installing the PCI-2513 12 Pinout – main I/O connector 16-channel single- ended pin out (8-channel differential signals in parentheses) Signal name Pin Pin Signal name ACH0 (ACH0 HI) 68 • • 34 ACH8 (ACH0 LO) AGND 67 • • 33 ACH1 (ACH1 HI) ACH9 (ACH1 LO) 66 • • 32 AGND ACH2 (ACH2 HI) 65 • • 31 ACH10 (ACH2 ...

  • Measurement Specialties PCI-2513 - page 13

    PCI-2513 User's Guide Installing the PCI-2513 13 68 34 13 5 34 1 68 35 Figure 2. CA-68-3S and CA-68-6S cable Field wiring and signal termination You can use the following MCC screw term inal boards to t erminate field signals and route them into the PCI- 2513 boar d using the C A-68-3R, C A-68-3S, o r CA-68-6S cable:  TB-100 : Termination b ...

  • Measurement Specialties PCI-2513 - page 14

    14 Chapter 3 Functional Details This chapter contains detailed information on all of the fe atures available from the board, i ncluding:  a block diag ram of b oard funct ions  informati on on how to use , when to use , and when n ot to use the si gnals generat ed by the board  diagrams of signals usi ng defaul t or convent ional boar d se ...

  • Measurement Specialties PCI-2513 - page 15

    PCI-2513 User's Guide Functional Details 15 Bus mastering DMA The PCI-2513 supports bus mastering DMA. With multiple DMA channels, analog, digital, and co unter input data, as well as digital out put data, ca n flow bet ween the PC and the PCI- 2513 without consum ing valuable CPU time. The driver supplied with the PCI-2513 automati cally uses ...

  • Measurement Specialties PCI-2513 - page 16

    PCI-2513 User's Guide Functional Details 16 Digital I/O Twenty-four TTL-level digital I/O lines are in cluded in each PCI-2513. You can program digital I/O in 8-bit groups as either inputs or outputs and scan the m in several modes (see " Digital input scanning " below). You can access input ports asynchronously from the PC at any ti ...

  • Measurement Specialties PCI-2513 - page 17

    PCI-2513 User's Guide Functional Details 17 3. Bring the analog input signal to ward the desired threshold. When the input sig nal is at the threshold (± some tolerance) the sweep will be triggered. 4. Before re-arming the trigger, again move the analog input signal to a level that is more than 2.5% of the full-scale range away fro m the desi ...

  • Measurement Specialties PCI-2513 - page 18

    PCI-2513 User's Guide Functional Details 18 Pre-triggering and post-triggering modes The PCI-2513 suppo rts four modes o f pre-triggering and post-triggering , providing a wide-variety of options to accommodate any measurem ent re quirement. When using pre-trigger, you must use software-b ased triggering to initiate an acquisition. No pre-trig ...

  • Measurement Specialties PCI-2513 - page 19

    PCI-2513 User's Guide Functional Details 19 Mapped channels A mapped channel is one of four coun ter input signals that can get multiplexed into a coun ter module. The mapped channel can particip ate with the counter's in put si gnal by gating the counter, latch ing the counter, and so on. The four possible choices for th e mapped channel ...

  • Measurement Specialties PCI-2513 - page 20

    PCI-2513 User's Guide Functional Details 20 Gating "on" mode Sets the gatin g option t o "on" fo r the mapped channel, enabl ing the m apped chan nel to gat e the counter. Any counte r can be gat ed by t he mapped cha nnel. When t he ma pped channel is high , the counter is enabled. When the m apped channel i s low , the co ...

  • Measurement Specialties PCI-2513 - page 21

    PCI-2513 User's Guide Functional Details 21 Figure 7. Debounce module – trigger after stable mode The followin g time peri ods (T1 throu gh T5) pert ain to Figure 7 . In tri gger after st able m ode, the input signal to the debounce module is re quired to have a period of stability after an incoming edge, i n order for that edge to be accept ...

  • Measurement Specialties PCI-2513 - page 22

    PCI-2513 User's Guide Functional Details 22 Debounce mode comparisons Figure 9 shows how the two modes interpret the same input sig nal, which exhibits glitches. Notice that the trigger before stable mode recognizes more glitches than the trigger after stable mode. Use the by pass option to achieve maximum glitch recognition. Figure 9. Example ...

  • Measurement Specialties PCI-2513 - page 23

    PCI-2513 User's Guide Functional Details 23 Figure 11. Optimal debounce time for trigger after stable mode Timer outputs Two 16-bit timer outputs are built into ev ery 3000 series board. Each timer is capable of generating a different square wave with a program mable frequ ency in the ra nge of 16 Hz to 1 MHz. Figure 12. Typical PCI-2513 timer ...

  • Measurement Specialties PCI-2513 - page 24

    PCI-2513 User's Guide Functional Details 24 Using detection setpoints for output control What are detection setpoints? With the PCI- 2513's setpoi nt configurati on feature, y ou can confi gure up to 16 detect ion setpoi nts associated with channels in a scan group. Each setpoint can update the following, allowing for real-time control ba ...

  • Measurement Specialties PCI-2513 - page 25

    PCI-2513 User's Guide Functional Details 25 Action - driven by condition Compare X to: Setpoint definiti on (choose one) Upda te conditions: Limit A or Li mit B  Equal to A (X = A)  Below A (X < A)  Above B (X > B) True only:  If True , then output value 1  If False , then perform no action True and False :  If True , t ...

  • Measurement Specialties PCI-2513 - page 26

    PCI-2513 User's Guide Functional Details 26 Setpoint configuration You program all setpoints as part of the pre-acquisition setup, similar to setting up an external trigger. Since each setpoint acts on 16-bit data, each ha s two 16-bit c ompare values: a high limit ( limit A ) and a low limit ( limit B ). These limits define the setpoint windo ...

  • Measurement Specialties PCI-2513 - page 27

    PCI-2513 User's Guide Functional Details 27 Using the setpoint status register You can use the setpoint stat us register to check the current state of the 16 pos sible setpoints. In the register, Setpoint 0 is the least-significant bit an d Setpoint 15 is the m ost-significant bi t. Each setpoi nt is assign ed a value of 0 or 1.  A value of ...

  • Measurement Specialties PCI-2513 - page 28

    PCI-2513 User's Guide Functional Details 28 You can program control outputs program med on each setpoint, and use th e de tection for channel 4 to update the FIRSTPORTC digital output port with one value (70 h in the example) when the analog input voltage is within the sha ded region and a differ ent value when the analog input voltage is outs ...

  • Measurement Specialties PCI-2513 - page 29

    PCI-2513 User's Guide Functional Details 29 Figure 16. Channel 3 in hysteresis mode Detecting setpoints on a totalizing counter In the following figure, Channel 1 is a coun ter in totalize mode. Two setpoints define a point of ch ange for Detect 1 as the counter count s upward. T he detect out put is hig h when insi de the wi ndow (greater tha ...

  • Measurement Specialties PCI-2513 - page 30

    PCI-2513 User's Guide Functional Details 30 inside the window . There is one update value that g ets applied when the inp ut values are less than the w indow and a different update value that ge ts applied when the input valu es are greater than the window. Update on True and False uses tw o update values . The update val ues can drive FIRSTPO ...

  • Measurement Specialties PCI-2513 - page 31

    PCI-2513 User's Guide Functional Details 31 There are three possible sol utions for o vercoming t his problem :  Shorten the scan period to give m ore timing resol ution on the c ounter values or analog va lues.  Widen the setpoint window by increasing limit A and/or lowering limit B. A combinat ion of bot h solutions (1 and 2) c ould be ...

  • Measurement Specialties PCI-2513 - page 32

    32 Chapter 4 Calibrating the PCI-2513 Every range of a PCI-2513 device is calibrated at the f actory using a digital NIS T traceable calibration method. This method works by st oring a correcti on factor for eac h range on the unit at the time of calibration. Fo r analog inputs, the user can adjust the calibration of the board while it is installed ...

  • Measurement Specialties PCI-2513 - page 33

    33 Chapter 5 Specifications Typical for 25 °C unless other wise specified. Specifications in italic text are guarantee d by design. Analog input Table 1. Analog input specifications A/D converter type Su ccessive approximation Resolution 16 bits Number of channels 16 single-ended/8 differential, soft ware-s electable Input ranges (SW programmable) ...

  • Measurement Specialties PCI-2513 - page 34

    PCI-2513 User's Guide Specifications 34 Digital input / output Table 3. Digital input/output specific ations Number of I/O 24 Ports Three banks of 8. Each port is programmable as in put or output Input scanning mode Asynchronous, under program control at any time relative to input scanning Configuration 10 k Ω pull-up to +5 V, 20 pf to analo ...

  • Measurement Specialties PCI-2513 - page 35

    PCI-2513 User's Guide Specifications 35 Input sequencer Analog, digi tal, and co unter inp uts can be scanne d based o n either an int ernal pro grammable ti mer or an external clock source. Table 5. Input sequenc er specificatio ns Scan clock sources: tw o (Note 3) Internal:  Analog channels from 1 µs to 1 sec in 20.83 ns steps.  Digit ...

  • Measurement Specialties PCI-2513 - page 36

    PCI-2513 User's Guide Specifications 36 Frequency/pulse generators Table 7. Frequency/pu lse generator specifications Channels 2 x 16-bit Output waveform Square wave Output rate 1 MHz base rate di vided by 1 to 65535 (programmable) High-level output voltage 2. 0 V minimum @ -1.0 mA, 2.9 V minimum @ -400 µA Low-level output voltage 0.4 V maxim ...

  • Measurement Specialties PCI-2513 - page 37

    PCI-2513 User's Guide Specifications 37 Table 13. 16-channel si ngle-ended pin out Pin Function Pin Function 68 ACH0 34 ACH8 67 AGND 33 ACH1 66 ACH9 32 AGND 65 ACH2 31 ACH10 64 AGND 30 ACH3 63 ACH11 29 AGND 62 SGND (low level sense – not for general use) 28 ACH4 61 ACH12 27 AGND 60 ACH5 26 ACH13 59 AGND 25 ACH6 58 ACH14 24 AGND 57 ACH7 23 AC ...

  • Measurement Specialties PCI-2513 - page 38

    PCI-2513 User's Guide Specifications 38 Table 14. 8-channel differ ential pin out Pin Function Pin Function 68 ACH0 HI 34 ACH0 LO 67 AGND 33 ACH1 HI 66 ACH1 LO 32 AGND 65 ACH2 HI 31 ACH2 LO 64 AGND 30 ACH3 HI 63 ACH3 LO 29 AGND 62 SGND (low level sense – not for general use) 28 ACH4 HI 61 ACH4 LO 27 AGND 60 ACH5 HI 26 ACH5 LO 59 AGND 25 ACH6 ...

  • Measurement Specialties PCI-2513 - page 39

    Declaration of Conformity Manufacturer: IOTe ch, Incorpor ated Address: 25971 Cannon Road Cleveland, OH 44146 USA Category: Inform ation technol ogy equi pment. IOTech, Incorporated d eclares under sole responsibility that the produ ct PCI-2513 to which this declaration relates is in conformity with th e rel evant provi sions of t he followin g sta ...

  • Measurement Specialties PCI-2513 - page 40

    Measurement Computing Cor poration 10 Comme rce Wa y Suite 1008 Norton, Massachusetts 02766 (508) 946-5100 Fax: (508) 946-9500 E-mail: info@mccdaq.com www.mccdaq.co m ...

Fabbricante Measurement Specialties Categoria Computer Hardware

I documenti che otteniamo dal fabbricante del dispositivoMeasurement Specialties PCI-2513 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Measurement Specialties
- manuali per l’uso PCI-2513
- schede prodotto Measurement Specialties
- opuscoli
- o etichette energetiche Measurement Specialties PCI-2513
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Measurement Specialties PCI-2513.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Measurement Specialties PCI-2513, manuali di manutenzione, brevi manuali o manuali utente Measurement Specialties PCI-2513. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Measurement Specialties PCI-2513.

Manuale completo del dispositivo Measurement Specialties PCI-2513, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Measurement Specialties PCI-2513 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Measurement Specialties PCI-2513.

Il manuale per l’uso completo Measurement Specialties, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Measurement Specialties PCI-2513 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Measurement Specialties PCI-2513, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Measurement Specialties PCI-2513 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Measurement Specialties PCI-2513 - che ci dovrebbe aiutare nei primi passi durante l'uso Measurement Specialties PCI-2513
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Measurement Specialties PCI-2513
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Measurement Specialties PCI-2513 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Measurement Specialties PCI-2513?

Utilizza il modulo sottostante

Se non hai risolto il problema con Measurement Specialties PCI-2513 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Measurement Specialties PCI-2513 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)