Manuale per l’uso Bay Technical Associates U140E116-02

27 pagine 0.06 mb
Scarica

Vai alla pagina of 27

Summary
  • Bay Technical Associates U140E116-02 - page 1

    1 OWNER'S MANUAL ________________ V93A DAC: 14.4k bps HOST COMMUNICATION MODEM MODULE FOR BAYTECH M-SERIES DAC BayTech Manual Publication #U140E116-02 ...

  • Bay Technical Associates U140E116-02 - page 2

    2 FCC REQUIREMENTS FOR THE V93A HOST COMMUNICATION MODEM MODULE 1. The Federal Communications Commission (FCC) has established rules which permit this device to be directly connected to the telephone network. Standardized jacks are used for these connections. This equipment should not be used on party lines or coin lines. 2. If this device is malfu ...

  • Bay Technical Associates U140E116-02 - page 3

    3 The ringer equivalence number (REN) is used to determine how many devices can be connected to your telephone line. In most areas, the sum of the RENs of all devices on any one line should not exceed five (5.0). If too many devices are attached, they may not ring properly. In the event of equipment malfunction, all repairs should be performed by o ...

  • Bay Technical Associates U140E116-02 - page 4

    4 TABLE OF CONTENTS 1 GENERAL INFORMATION ............................................................................................................... 6 2 SPECIFICATIONS ............................................................................................................................ 7 3 SOFTWARE UTILITY DISKETTE ...................... ...

  • Bay Technical Associates U140E116-02 - page 5

    5 .7 LOGIN PASSWORD ................................................................................................................. 21 .8 LOCAL MODEM SETUP ............................................................................................................ 22 .9 EXIT ........................................................................ ...

  • Bay Technical Associates U140E116-02 - page 6

    6 1 GENERAL INFORMATION The V93A Host Communication Modem Module is the remote user interface to the BayTech M Series DAC (Data Acquisition and Control) units. This module features a V.32bis/V.42bis internal modem and allows a remote host terminal to connect and issue specific configuration or data commands to the various I/O modules or the M Serie ...

  • Bay Technical Associates U140E116-02 - page 7

    7 2 SPECIFICATIONS INTERFACE: Dial-up telephone line MODULATION: V.32bis (14,400 bps) or V.32 (9600 bps) COMPRESSION: V.42bis, MNP5 CONNECTORS: 2 x 4-pin modular MODULE LEDS: TD (Transmit Data), RD (Receive Data), CD (Carrier Detect), MR (Modem Ready), and CX (Connection) status LEDs. TRANSMIT LEVEL: -10 dBm (dial-up) RECEIVER SENSITIVITY: -45 dBm ...

  • Bay Technical Associates U140E116-02 - page 8

    8 3 SOFTWARE UTILITY DISKETTE IMPORTANT: Copy the BayTech original diskette onto a blank diskette and store the original in a safe place. BayTech provides utility software for DOS compatible PCs to assist you in configuring your M-Series DAC unit. This diskette contains several programs, however the only programs that will be used is TERM.EXE and R ...

  • Bay Technical Associates U140E116-02 - page 9

    9 Figure 1 shows the required adapter for a PC with a DB-25 connector. Use a crossed RJ-45 cable to connect these adapters to the EIA-232 port. BLUE ORANGE BLACK RED GREEN YELLOW BROWN GRAY 1 1 2 3 4 5 6 7 8 8 7 6 5 4 3 2 TX RX RTS CTS DSR GND DCD DTR FEMALE DE-9 RJ-45 Figure 1: PC, PS/2 Computer/Terminal Adapter BayTech Part No. 9FRJ45PC-3 Figure ...

  • Bay Technical Associates U140E116-02 - page 10

    10 GRAY BROWN YELLOW GREEN RED BLACK ORANGE BLUE RJ-45 FEMALE DB-25 CTS TX DSR GND DTR DCD RX RTS 2 3 4 5 6 7 8 20 8 7 6 5 4 3 2 1 Figure 2: PC, PS/2 Computer/Terminal Adapter BayTech Part No. 25FRJ45PC-3 IMPORTANT : When modular connectors are used as shown in Figures 1 - 2 above with RJ-45 connectors, crossed RJ-45 cables are required. See the ca ...

  • Bay Technical Associates U140E116-02 - page 11

    11 .2 MODEM CONNECTION Connect the phone line to the RJ-11 connector on the V93A with a RJ-11 cable. 5 OPERATION a. You are ready to perform commands when a terminal or PC is communicating with: (1) the V93A's EIA-232 port. (2) a remote modem is communicating with the V93A’s modem. b. If you are using a PC, you can communicate with the V93A ...

  • Bay Technical Associates U140E116-02 - page 12

    12 Unit 2 Module 1 REV. 4.XX Copyright (c) 1995-1997 Bay Technical Associates To login, enter password Login: BTA (default) You will be prompted to type in the desired password followed by <ENTER> when a connection to the V93A modem is first made. You are given three tries to type in the correct password before the modem hangs up. Type the ap ...

  • Bay Technical Associates U140E116-02 - page 13

    13 Device B (2,2)............2 Device C (2,3)............3 Device D (2,4)............4 Configure.........................C Manual Mode.......................M Exit..............................X Unit Reset........................R Logout............................T Enter Request : The device names in the menu correspond to the device names assigne ...

  • Bay Technical Associates U140E116-02 - page 14

    14 By responding to the Enter Request : message at the end of the V93A menu with “M” you receive a response similar to the following: Device A (2,1).................... 1 Device B (2,2).................... 2 Device C (2,3).................... 3 Device D (2,4).................... 4 Device A (3,1).................... 5 Device B (3,2)............. ...

  • Bay Technical Associates U140E116-02 - page 15

    15 .5 UNIT RESET Users can instruct the M-Series DAC with the V93A module, to “reset ” by using the Menu Selection Method to reset the unit. The Unit Reset command does not affect any saved configuration parameters that have been changed from the default values. By responding to the Enter Request: message at the end of the menu with “R”(Uni ...

  • Bay Technical Associates U140E116-02 - page 16

    16 By responding to the Enter Request : message in the V93A Main Menu with “T” (Logout ), you will take you out of menu mode If you have a modem connection it will terminate that connection. The V93A host module will respond with a message similar to the following: Device A (2,1).................... 1 Device B (2,2).................... 2 Device ...

  • Bay Technical Associates U140E116-02 - page 17

    17 Enter Request : .1 STATUS By responding to the menu with a "1" (Status ), you can review the current configuration of the V93A. Below is the default status. Installed Modules :1,2 Port Select Code is................$BT Attention Character is.............; Disconnect Time Guard is...........Disabled Local Modem Setup : Rings to Auto-Ans ...

  • Bay Technical Associates U140E116-02 - page 18

    18 Exit/Save......1 Set Stop Bits.....4 Set Baud Rate..2 Set Parity........5 Set Word Size..3 Set Xon/Xoff......6 Enter Request : You can now reconfigure the V93A EIA-232 port by sending the appropriate option (1 to 6) from the menu. For example, to change the baud rate to 115.2K, send "2" (Set Baud Rate ). The V93A will respond with: 1 F ...

  • Bay Technical Associates U140E116-02 - page 19

    19 If you type "Y", the new configuration for the selected port is stored permanently in non-volatile memory until. If you type “N” t he V93A will return to the main configuration menu . NOTE: If you are configuring the V93A from the EIA-232 port, the V93A will respond with: Change Device to NEW Configuration Before Answering This Req ...

  • Bay Technical Associates U140E116-02 - page 20

    20 Enter Port Device Name (Max. 16 characters): or ENTER for no change ...........: If the Port Device Name is satisfactory, type <ENTER>. The V93A will return to the main configuration menu. NOTE: If the V93A Connect Port ID Echo feature is programmed for Use Device Name, the message sent to the host device when the host selects a V74/V75 pe ...

  • Bay Technical Associates U140E116-02 - page 21

    21 Type "Y" to change the Attention Character. The V93A will respond with: Enter Attention Character : Type the desired Attention Character. For example, if you type "%", the V93A will respond with Attention Character is............ % Change It ? (Y/N) : Type "N" if no additional change is desired. The V93A will store ...

  • Bay Technical Associates U140E116-02 - page 22

    22 Enter New Password( 1 - 8 char., CR to end): If the Login Password is correct, type "N". The V93A will store the new Login Password into non-volatile memory and return to the main configuration menu. .8 LOCAL MODEM SETUP By responding with “8” (Local Modem Setup ), you can change the Rings to Answer and the Connectivity Time-out. T ...

  • Bay Technical Associates U140E116-02 - page 23

    23 This time-out can be programmed from 5 to 255 minutes, or 0 (=disable). The timer is started when the modem goes off-hook (DCD goes high), and the modem will return to “on hook” after the time-out has expired. The factory default is 0 (disabled). .9 EXIT By responding with "X" (Exit ), you will exit configuration mode. At this poin ...

  • Bay Technical Associates U140E116-02 - page 24

    24 The V93A has five LEDs on the rear panel that indicate the modem status: TD , RD , CD , MR , and CX . These LEDs are described below. LED Description TD Transmit Data: Indicates the modem is transmitting data. RD Receive Data: Indicates the modem is receiving data. CD Carrier Detect: Indicates a valid carrier tone has been detected. MR Modem Rea ...

  • Bay Technical Associates U140E116-02 - page 25

    25 pliers from side to side, so as not to bend chip pins. Pull loosened EPROM all the way out. 4. Install the new EPROM into socket U2 . The EPROM is notched; the notch on the EPROM should line up with the notch on the socket. Be careful not to bend any of the pins. Make sure none of the pins miss their sockets. If the socket has more holes than ch ...

  • Bay Technical Associates U140E116-02 - page 26

    26 8 V93A MECHANICAL LAYOUT SN: PN:M330A048A C15 C16 C19 C5 C6 C8 C9 J2 L1 L2 LED1 LED2 LED3 LED4 LED5 M1 R6 R7 U10 U11 U2 U8 U9 R9 F1 F2 K K > > È È F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F Error! Switch argument not specified. ...

  • Bay Technical Associates U140E116-02 - page 27

    27 9 INDEX —A— ASCII character , 19 Attention Character , 19 Auto-Answer, 20 —C— Case sensitive , 15 Communications program , 10 Configuration menu , 17 —D— DCD Logon/Logoff, 21 Disconnect Time Guard , 19 —E— Emulation , 11 Exit , 14, 21 —H— Header , 20 —I— ID Echo , 18 —L— Local Modem Setup, 20 Login Password , 20 Login ...

Fabbricante Bay Technical Associates Categoria Network Card

I documenti che otteniamo dal fabbricante del dispositivoBay Technical Associates U140E116-02 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Bay Technical Associates
- manuali per l’uso U140E116-02
- schede prodotto Bay Technical Associates
- opuscoli
- o etichette energetiche Bay Technical Associates U140E116-02
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Bay Technical Associates U140E116-02.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Bay Technical Associates U140E116-02, manuali di manutenzione, brevi manuali o manuali utente Bay Technical Associates U140E116-02. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Bay Technical Associates U140E116-02.

Manuale completo del dispositivo Bay Technical Associates U140E116-02, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Bay Technical Associates U140E116-02 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Bay Technical Associates U140E116-02.

Il manuale per l’uso completo Bay Technical Associates, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Bay Technical Associates U140E116-02 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Bay Technical Associates U140E116-02, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Bay Technical Associates U140E116-02 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Bay Technical Associates U140E116-02 - che ci dovrebbe aiutare nei primi passi durante l'uso Bay Technical Associates U140E116-02
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Bay Technical Associates U140E116-02
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Bay Technical Associates U140E116-02 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Bay Technical Associates U140E116-02?

Utilizza il modulo sottostante

Se non hai risolto il problema con Bay Technical Associates U140E116-02 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Bay Technical Associates U140E116-02 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)