Bay Technical Associates U140E116-02の取扱説明書

27ページ 0.06 mb
ダウンロード

ページに移動 of 27

Summary
  • Bay Technical Associates U140E116-02 - page 1

    1 OWNER'S MANUAL ________________ V93A DAC: 14.4k bps HOST COMMUNICATION MODEM MODULE FOR BAYTECH M-SERIES DAC BayTech Manual Publication #U140E116-02 ...

  • Bay Technical Associates U140E116-02 - page 2

    2 FCC REQUIREMENTS FOR THE V93A HOST COMMUNICATION MODEM MODULE 1. The Federal Communications Commission (FCC) has established rules which permit this device to be directly connected to the telephone network. Standardized jacks are used for these connections. This equipment should not be used on party lines or coin lines. 2. If this device is malfu ...

  • Bay Technical Associates U140E116-02 - page 3

    3 The ringer equivalence number (REN) is used to determine how many devices can be connected to your telephone line. In most areas, the sum of the RENs of all devices on any one line should not exceed five (5.0). If too many devices are attached, they may not ring properly. In the event of equipment malfunction, all repairs should be performed by o ...

  • Bay Technical Associates U140E116-02 - page 4

    4 TABLE OF CONTENTS 1 GENERAL INFORMATION ............................................................................................................... 6 2 SPECIFICATIONS ............................................................................................................................ 7 3 SOFTWARE UTILITY DISKETTE ...................... ...

  • Bay Technical Associates U140E116-02 - page 5

    5 .7 LOGIN PASSWORD ................................................................................................................. 21 .8 LOCAL MODEM SETUP ............................................................................................................ 22 .9 EXIT ........................................................................ ...

  • Bay Technical Associates U140E116-02 - page 6

    6 1 GENERAL INFORMATION The V93A Host Communication Modem Module is the remote user interface to the BayTech M Series DAC (Data Acquisition and Control) units. This module features a V.32bis/V.42bis internal modem and allows a remote host terminal to connect and issue specific configuration or data commands to the various I/O modules or the M Serie ...

  • Bay Technical Associates U140E116-02 - page 7

    7 2 SPECIFICATIONS INTERFACE: Dial-up telephone line MODULATION: V.32bis (14,400 bps) or V.32 (9600 bps) COMPRESSION: V.42bis, MNP5 CONNECTORS: 2 x 4-pin modular MODULE LEDS: TD (Transmit Data), RD (Receive Data), CD (Carrier Detect), MR (Modem Ready), and CX (Connection) status LEDs. TRANSMIT LEVEL: -10 dBm (dial-up) RECEIVER SENSITIVITY: -45 dBm ...

  • Bay Technical Associates U140E116-02 - page 8

    8 3 SOFTWARE UTILITY DISKETTE IMPORTANT: Copy the BayTech original diskette onto a blank diskette and store the original in a safe place. BayTech provides utility software for DOS compatible PCs to assist you in configuring your M-Series DAC unit. This diskette contains several programs, however the only programs that will be used is TERM.EXE and R ...

  • Bay Technical Associates U140E116-02 - page 9

    9 Figure 1 shows the required adapter for a PC with a DB-25 connector. Use a crossed RJ-45 cable to connect these adapters to the EIA-232 port. BLUE ORANGE BLACK RED GREEN YELLOW BROWN GRAY 1 1 2 3 4 5 6 7 8 8 7 6 5 4 3 2 TX RX RTS CTS DSR GND DCD DTR FEMALE DE-9 RJ-45 Figure 1: PC, PS/2 Computer/Terminal Adapter BayTech Part No. 9FRJ45PC-3 Figure ...

  • Bay Technical Associates U140E116-02 - page 10

    10 GRAY BROWN YELLOW GREEN RED BLACK ORANGE BLUE RJ-45 FEMALE DB-25 CTS TX DSR GND DTR DCD RX RTS 2 3 4 5 6 7 8 20 8 7 6 5 4 3 2 1 Figure 2: PC, PS/2 Computer/Terminal Adapter BayTech Part No. 25FRJ45PC-3 IMPORTANT : When modular connectors are used as shown in Figures 1 - 2 above with RJ-45 connectors, crossed RJ-45 cables are required. See the ca ...

  • Bay Technical Associates U140E116-02 - page 11

    11 .2 MODEM CONNECTION Connect the phone line to the RJ-11 connector on the V93A with a RJ-11 cable. 5 OPERATION a. You are ready to perform commands when a terminal or PC is communicating with: (1) the V93A's EIA-232 port. (2) a remote modem is communicating with the V93A’s modem. b. If you are using a PC, you can communicate with the V93A ...

  • Bay Technical Associates U140E116-02 - page 12

    12 Unit 2 Module 1 REV. 4.XX Copyright (c) 1995-1997 Bay Technical Associates To login, enter password Login: BTA (default) You will be prompted to type in the desired password followed by <ENTER> when a connection to the V93A modem is first made. You are given three tries to type in the correct password before the modem hangs up. Type the ap ...

  • Bay Technical Associates U140E116-02 - page 13

    13 Device B (2,2)............2 Device C (2,3)............3 Device D (2,4)............4 Configure.........................C Manual Mode.......................M Exit..............................X Unit Reset........................R Logout............................T Enter Request : The device names in the menu correspond to the device names assigne ...

  • Bay Technical Associates U140E116-02 - page 14

    14 By responding to the Enter Request : message at the end of the V93A menu with “M” you receive a response similar to the following: Device A (2,1).................... 1 Device B (2,2).................... 2 Device C (2,3).................... 3 Device D (2,4).................... 4 Device A (3,1).................... 5 Device B (3,2)............. ...

  • Bay Technical Associates U140E116-02 - page 15

    15 .5 UNIT RESET Users can instruct the M-Series DAC with the V93A module, to “reset ” by using the Menu Selection Method to reset the unit. The Unit Reset command does not affect any saved configuration parameters that have been changed from the default values. By responding to the Enter Request: message at the end of the menu with “R”(Uni ...

  • Bay Technical Associates U140E116-02 - page 16

    16 By responding to the Enter Request : message in the V93A Main Menu with “T” (Logout ), you will take you out of menu mode If you have a modem connection it will terminate that connection. The V93A host module will respond with a message similar to the following: Device A (2,1).................... 1 Device B (2,2).................... 2 Device ...

  • Bay Technical Associates U140E116-02 - page 17

    17 Enter Request : .1 STATUS By responding to the menu with a "1" (Status ), you can review the current configuration of the V93A. Below is the default status. Installed Modules :1,2 Port Select Code is................$BT Attention Character is.............; Disconnect Time Guard is...........Disabled Local Modem Setup : Rings to Auto-Ans ...

  • Bay Technical Associates U140E116-02 - page 18

    18 Exit/Save......1 Set Stop Bits.....4 Set Baud Rate..2 Set Parity........5 Set Word Size..3 Set Xon/Xoff......6 Enter Request : You can now reconfigure the V93A EIA-232 port by sending the appropriate option (1 to 6) from the menu. For example, to change the baud rate to 115.2K, send "2" (Set Baud Rate ). The V93A will respond with: 1 F ...

  • Bay Technical Associates U140E116-02 - page 19

    19 If you type "Y", the new configuration for the selected port is stored permanently in non-volatile memory until. If you type “N” t he V93A will return to the main configuration menu . NOTE: If you are configuring the V93A from the EIA-232 port, the V93A will respond with: Change Device to NEW Configuration Before Answering This Req ...

  • Bay Technical Associates U140E116-02 - page 20

    20 Enter Port Device Name (Max. 16 characters): or ENTER for no change ...........: If the Port Device Name is satisfactory, type <ENTER>. The V93A will return to the main configuration menu. NOTE: If the V93A Connect Port ID Echo feature is programmed for Use Device Name, the message sent to the host device when the host selects a V74/V75 pe ...

  • Bay Technical Associates U140E116-02 - page 21

    21 Type "Y" to change the Attention Character. The V93A will respond with: Enter Attention Character : Type the desired Attention Character. For example, if you type "%", the V93A will respond with Attention Character is............ % Change It ? (Y/N) : Type "N" if no additional change is desired. The V93A will store ...

  • Bay Technical Associates U140E116-02 - page 22

    22 Enter New Password( 1 - 8 char., CR to end): If the Login Password is correct, type "N". The V93A will store the new Login Password into non-volatile memory and return to the main configuration menu. .8 LOCAL MODEM SETUP By responding with “8” (Local Modem Setup ), you can change the Rings to Answer and the Connectivity Time-out. T ...

  • Bay Technical Associates U140E116-02 - page 23

    23 This time-out can be programmed from 5 to 255 minutes, or 0 (=disable). The timer is started when the modem goes off-hook (DCD goes high), and the modem will return to “on hook” after the time-out has expired. The factory default is 0 (disabled). .9 EXIT By responding with "X" (Exit ), you will exit configuration mode. At this poin ...

  • Bay Technical Associates U140E116-02 - page 24

    24 The V93A has five LEDs on the rear panel that indicate the modem status: TD , RD , CD , MR , and CX . These LEDs are described below. LED Description TD Transmit Data: Indicates the modem is transmitting data. RD Receive Data: Indicates the modem is receiving data. CD Carrier Detect: Indicates a valid carrier tone has been detected. MR Modem Rea ...

  • Bay Technical Associates U140E116-02 - page 25

    25 pliers from side to side, so as not to bend chip pins. Pull loosened EPROM all the way out. 4. Install the new EPROM into socket U2 . The EPROM is notched; the notch on the EPROM should line up with the notch on the socket. Be careful not to bend any of the pins. Make sure none of the pins miss their sockets. If the socket has more holes than ch ...

  • Bay Technical Associates U140E116-02 - page 26

    26 8 V93A MECHANICAL LAYOUT SN: PN:M330A048A C15 C16 C19 C5 C6 C8 C9 J2 L1 L2 LED1 LED2 LED3 LED4 LED5 M1 R6 R7 U10 U11 U2 U8 U9 R9 F1 F2 K K > > È È F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F Error! Switch argument not specified. ...

  • Bay Technical Associates U140E116-02 - page 27

    27 9 INDEX —A— ASCII character , 19 Attention Character , 19 Auto-Answer, 20 —C— Case sensitive , 15 Communications program , 10 Configuration menu , 17 —D— DCD Logon/Logoff, 21 Disconnect Time Guard , 19 —E— Emulation , 11 Exit , 14, 21 —H— Header , 20 —I— ID Echo , 18 —L— Local Modem Setup, 20 Login Password , 20 Login ...

メーカー Bay Technical Associates カテゴリー Network Card

Bay Technical Associates U140E116-02のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- U140E116-02の取扱説明書
- Bay Technical Associatesの製品カード
- パンフレット
- またはBay Technical Associates U140E116-02の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Bay Technical Associates U140E116-02の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Bay Technical Associates U140E116-02の取り付け説明書、サービスマニュアル、簡易説明書、またはBay Technical Associates U140E116-02のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Bay Technical Associates U140E116-02の製品を使用するにあたって最も人気のある説明書を閲覧できます。

Bay Technical Associates U140E116-02デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBay Technical Associates U140E116-02を使用するのを助ける技術的文書のことです。説明書は通常、全てのBay Technical Associates U140E116-02ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Bay Technical Associatesの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Bay Technical Associates U140E116-02の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBay Technical Associates U140E116-02の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Bay Technical Associates U140E116-02に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Bay Technical Associates U140E116-02デバイスの基本機能を使うにあたってのヒント。 Bay Technical Associates U140E116-02のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Bay Technical Associates U140E116-02に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBay Technical Associates U140E116-02のメーカー/サービスへの連絡先に関する情報。

Bay Technical Associates U140E116-02についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBay Technical Associates U140E116-02の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBay Technical Associates U140E116-02で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください