Manuale per l’uso GE MDS 05-4558A01

20 pagine 0.66 mb
Scarica

Vai alla pagina of 20

Summary
  • GE MDS 05-4558A01 - page 1

    Star t-Up Guide Wireless IP/Ethernet Transceiver Covering all AP and Remote Units including Mercury 900, 3650, and Option Set 1 Remotes MDS 05-4558A01, Rev . C December 2008 MDS Mer cury ™ Series ...

  • GE MDS 05-4558A01 - page 2

    05-4558A01, Rev . C MDS Mercur y Series Star tup Guide 1 Contents PRODUCT DESCRIPTION ..................................................... 2 INST ALLA TION O VER VIEW ................................................... 2 INST ALLA TION STEPS .......................................................... 2 Step 1—Mount the T ransceiv er ............. ...

  • GE MDS 05-4558A01 - page 3

    2 MDS Mercur y Series Star tup Guide 05-4558A01, Rev . C PR ODUCT DESCRIPTION MDS Mercury TM Series transceivers provide an easy-to-install wire- less network service with long range and secure operation at adaptive data rates approaching 12 Mbps. The transceiver is ideally suited for demanding applications in mobile or fixed environments, where re ...

  • GE MDS 05-4558A01 - page 4

    05-4558A01, Rev . C MDS Mercur y Series Star tup Guide 3 Step 1—Mount the Transceiver Use the supplied 6-32 x 1/4 inch (6 mm) screws to attach the mounting brackets to the bottom of the radio. Figure 1 shows the mounting dimensions of the unit. Mount the radio to a stable surface. (Fasteners not normally supplied.) Invisible place holder Figure 1 ...

  • GE MDS 05-4558A01 - page 5

    4 MDS Mercur y Series Star tup Guide 05-4558A01, Rev . C Step 3—Measure & Connect Primary Power The DC input power to the transceiver must be within 10–30 Vdc and capable of continuously providing at least 2.5 Amperes. A power con- nector with screw-terminals is provided with each unit. Strip the wire leads to 6 mm (1/4 inch). Be sure to ob ...

  • GE MDS 05-4558A01 - page 6

    05-4558A01, Rev . C MDS Mercur y Series Star tup Guide 5 Other parameters commonly needing review or adjustment are: • RF Output P ower Le vel (AP Only)—Check and adjust as neces- sary for compliance with regulatory limits. (Default power is +30 dBm for 900 model, +20 dBm for 3650 model.) Note that Remotes “auto-adjust” power output based o ...

  • GE MDS 05-4558A01 - page 7

    6 MDS Mercur y Series Star tup Guide 05-4558A01, Rev . C Log-in and Configuration Procedure The following is an overview of the local log-in and configuration pro- cedure using the COM1 serial port. For detailed instructions on this, and other methods of control, refer to the Mercury Reference Manual . a. Connect a computer’ s serial port to the ...

  • GE MDS 05-4558A01 - page 8

    05-4558A01, Rev . C MDS Mercur y Series Star tup Guide 7 NOTE: Using Con fi guration Scripts under the Maintenance/T ools menu will aid in uniformly configuring multiple units. See the Mercury Reference Manual for details. Step 5—Connect the Data Equipment Connect Ethernet-compatible data equipment to the unit’s LAN port (10/100 BaseT), or one ...

  • GE MDS 05-4558A01 - page 9

    8 MDS Mercur y Series Star tup Guide 05-4558A01, Rev . C Scanning —The unit is looking for an Access Point beacon signal. Ranging —Unit is adjusting power, timing, and frequency with an AP. Connecting —Unit has an RF connection with the AP. A uthenticating —(When Device Authentication is in use) The Remote is authenticating itself to the ne ...

  • GE MDS 05-4558A01 - page 10

    MENU SYSTEM Flowchart CONNECTORS AND INDICA TORS LED FUNCTIONS & INDICA TIONS LAN  ......ON ............LAN detected Flashing ....Data TX/RX OFF ..........LAN not detected COM1  ...Flashing ....Data TX/RX Activity OFF ..........No data activity GPS  ...ON ............Has satellite fix Flashing ....Synchronizing OFF ..........No s ...

  • GE MDS 05-4558A01 - page 11

    TO DC POWER SUPPL Y (10–30 Vdc) RTU/PLC (Crossover Cable to Radio) LOW-LOSS FEEDLINE (T o 900 MHz Antenna) INST INST ALLA ALLA TION REFERENCE CHART TION REFERENCE CHART ANTENNA SYSTEM PC RUNNING TERMINAL PROGRAM (Straight-Through Cable to Radio) TO GPS ANTENNA (Provides 3.3 Vdc output) Step 1 – Mount the T ransceiver Step 2 – Install the Ante ...

  • GE MDS 05-4558A01 - page 12

    05-4558A01, Rev . C MDS Mercur y Series Star tup Guide 9 In general, signal levels stronger than –80 dBm will provide reliable communication in the network. RSSI measurements and Wireless Packet Statistics are based on multiple samples over a period of sev- eral seconds. The average of these measurements is displayed by the RSSI screen. In the st ...

  • GE MDS 05-4558A01 - page 13

    10 MDS Mercur y Series Star tup Guide 05-4558A01, Rev . C TRANSMITTER PO WER & ANTENNA TEST The following procedure may be used to measure the transmitter’s RF power output and SWR “match” of the antenna system. A directional wattmeter is required for the test, such as a Bird Model 43, with an appropriate element installed. Before you sta ...

  • GE MDS 05-4558A01 - page 14

    05-4558A01, Rev . C MDS Mercur y Series Star tup Guide 11 TR OUBLESHOO TING It is best to begin troubleshooting at the Access Point, as the rest of the system depends on it for network synchronization and configuration. If the Access Point has problems, the operation of the entire network will be affected. All radios in the network must meet these ...

  • GE MDS 05-4558A01 - page 15

    12 MDS Mercur y Series Star tup Guide 05-4558A01, Rev . C LINK LED not lit. a. Network Names of APs and Remotes do not match. They must be identical for association to occur—Also, verify that the system has a unique Network Name. b. Remote not yet associated with an Access Point with the same Network Name. Check the “Status” of the unit’s p ...

  • GE MDS 05-4558A01 - page 16

    05-4558A01, Rev . C MDS Mercur y Series Star tup Guide 13 Table 2. Troubleshooting with the Menu System Symptom Problem/Recommended System Checks Cannot Access the Remote or AP through COM1 Only occurs in three possible scenarios: —COM1 is damaged or the Unit is faulty. —COM1 is being used for Streaming GPS information to Console terminal. —C ...

  • GE MDS 05-4558A01 - page 17

    14 MDS Mercur y Series Star tup Guide 05-4558A01, Rev . C SPECIFICA TIONS GENERAL Temperature Range: –40° C to +70° C (–40° F to 158° F) Humidity: 95% at +40° C (104° F); non-condensing Primary Power: 10–30 Vdc External Power Supply Options: 48 Vdc; 110–120/210–220 Vac Typical Current Consumption (assumes 1 Watt RF Output): Size (wi ...

  • GE MDS 05-4558A01 - page 18

    05-4558A01, Rev . C MDS Mercur y Series Star tup Guide 15 PHYSICAL INTERFACE : Ethernet: 10/100BaseT, RJ-45 Serial: (COM1) RS-232, DB-9F APPROVALS: FCC Part 15.247 (DTS) CSA /US Class 1, Div. 2 Industry Canada RS-210 PROTOCOLS: Ethernet: IEEE 802.3, Spanning Tree (Bridging), VLAN, IGMP TCP/IP: DHCP, ICMP, UDP, TCP. ARP, Multicast, SNTP, TFTP Serial ...

  • GE MDS 05-4558A01 - page 19

    16 MDS Mercur y Series Star tup Guide 05-4558A01, Rev . C TECHNICAL ASSIST ANCE Technical assistance is available from our Technical Support Depart- ment during business hours (8:30 A.M.–7:00 P.M. Eastern Time). When calling, please give the complete model number of the radio, along with a description of the trouble symptom(s) that you are expe- ...

  • GE MDS 05-4558A01 - page 20

    GE MDS, LLC Rochester, NY 14620 General Business: +1 585 242-9600 FAX: +1 585 242-9620 Web: www.GEmds.com 175 Science Parkway ...

Fabbricante GE Categoria Network Router

I documenti che otteniamo dal fabbricante del dispositivoGE MDS 05-4558A01 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici GE
- manuali per l’uso MDS 05-4558A01
- schede prodotto GE
- opuscoli
- o etichette energetiche GE MDS 05-4558A01
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso GE MDS 05-4558A01.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione GE MDS 05-4558A01, manuali di manutenzione, brevi manuali o manuali utente GE MDS 05-4558A01. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto GE MDS 05-4558A01.

Manuali per l’uso simili

Manuale completo del dispositivo GE MDS 05-4558A01, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare GE MDS 05-4558A01 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti GE MDS 05-4558A01.

Il manuale per l’uso completo GE, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale GE MDS 05-4558A01 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice GE MDS 05-4558A01, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per GE MDS 05-4558A01 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo GE MDS 05-4558A01 - che ci dovrebbe aiutare nei primi passi durante l'uso GE MDS 05-4558A01
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del GE MDS 05-4558A01
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio GE MDS 05-4558A01 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su GE MDS 05-4558A01?

Utilizza il modulo sottostante

Se non hai risolto il problema con GE MDS 05-4558A01 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con GE MDS 05-4558A01 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)