    Star t-Up Guide Wireless IP/Ethernet Transceiver Covering all AP and Remote Units including Mercury 900, 3650, and Option Set 1 Remotes MDS 05-4558A01, Rev . C December 2008 MDS Mer cury ™ Series ...

  • GE MDS 05-4558A01 - page 2

    05-4558A01, Rev . C MDS Mercur y Series Star tup Guide 1 Contents PRODUCT DESCRIPTION ..................................................... 2 INST ALLA TION O VER VIEW ................................................... 2 INST ALLA TION STEPS .......................................................... 2 Step 1—Mount the T ransceiv er ............. ...

  • GE MDS 05-4558A01 - page 3

    2 MDS Mercur y Series Star tup Guide 05-4558A01, Rev . C PR ODUCT DESCRIPTION MDS Mercury TM Series transceivers provide an easy-to-install wire- less network service with long range and secure operation at adaptive data rates approaching 12 Mbps. The transceiver is ideally suited for demanding applications in mobile or fixed environments, where re ...

  • GE MDS 05-4558A01 - page 4

    05-4558A01, Rev . C MDS Mercur y Series Star tup Guide 3 Step 1—Mount the Transceiver Use the supplied 6-32 x 1/4 inch (6 mm) screws to attach the mounting brackets to the bottom of the radio. Figure 1 shows the mounting dimensions of the unit. Mount the radio to a stable surface. (Fasteners not normally supplied.) Invisible place holder Figure 1 ...

  • GE MDS 05-4558A01 - page 5

    4 MDS Mercur y Series Star tup Guide 05-4558A01, Rev . C Step 3—Measure & Connect Primary Power The DC input power to the transceiver must be within 10–30 Vdc and capable of continuously providing at least 2.5 Amperes. A power con- nector with screw-terminals is provided with each unit. Strip the wire leads to 6 mm (1/4 inch). Be sure to ob ...

  • GE MDS 05-4558A01 - page 6

    05-4558A01, Rev . C MDS Mercur y Series Star tup Guide 5 Other parameters commonly needing review or adjustment are: • RF Output P ower Le vel (AP Only)—Check and adjust as neces- sary for compliance with regulatory limits. (Default power is +30 dBm for 900 model, +20 dBm for 3650 model.) Note that Remotes “auto-adjust” power output based o ...

  • GE MDS 05-4558A01 - page 7

    6 MDS Mercur y Series Star tup Guide 05-4558A01, Rev . C Log-in and Configuration Procedure The following is an overview of the local log-in and configuration pro- cedure using the COM1 serial port. For detailed instructions on this, and other methods of control, refer to the Mercury Reference Manual . a. Connect a computer’ s serial port to the ...

  • GE MDS 05-4558A01 - page 8

    05-4558A01, Rev . C MDS Mercur y Series Star tup Guide 7 NOTE: Using Con fi guration Scripts under the Maintenance/T ools menu will aid in uniformly configuring multiple units. See the Mercury Reference Manual for details. Step 5—Connect the Data Equipment Connect Ethernet-compatible data equipment to the unit’s LAN port (10/100 BaseT), or one ...

  • GE MDS 05-4558A01 - page 9

    8 MDS Mercur y Series Star tup Guide 05-4558A01, Rev . C Scanning —The unit is looking for an Access Point beacon signal. Ranging —Unit is adjusting power, timing, and frequency with an AP. Connecting —Unit has an RF connection with the AP. A uthenticating —(When Device Authentication is in use) The Remote is authenticating itself to the ne ...

  • GE MDS 05-4558A01 - page 10

    MENU SYSTEM Flowchart CONNECTORS AND INDICA TORS LED FUNCTIONS & INDICA TIONS LAN  ......ON ............LAN detected Flashing ....Data TX/RX OFF ..........LAN not detected COM1  ...Flashing ....Data TX/RX Activity OFF ..........No data activity GPS  ...ON ............Has satellite fix Flashing ....Synchronizing OFF ..........No s ...

  • GE MDS 05-4558A01 - page 11

    TO DC POWER SUPPL Y (10–30 Vdc) RTU/PLC (Crossover Cable to Radio) LOW-LOSS FEEDLINE (T o 900 MHz Antenna) INST INST ALLA ALLA TION REFERENCE CHART TION REFERENCE CHART ANTENNA SYSTEM PC RUNNING TERMINAL PROGRAM (Straight-Through Cable to Radio) TO GPS ANTENNA (Provides 3.3 Vdc output) Step 1 – Mount the T ransceiver Step 2 – Install the Ante ...

  • GE MDS 05-4558A01 - page 12

    05-4558A01, Rev . C MDS Mercur y Series Star tup Guide 9 In general, signal levels stronger than –80 dBm will provide reliable communication in the network. RSSI measurements and Wireless Packet Statistics are based on multiple samples over a period of sev- eral seconds. The average of these measurements is displayed by the RSSI screen. In the st ...

  • GE MDS 05-4558A01 - page 13

    10 MDS Mercur y Series Star tup Guide 05-4558A01, Rev . C TRANSMITTER PO WER & ANTENNA TEST The following procedure may be used to measure the transmitter’s RF power output and SWR “match” of the antenna system. A directional wattmeter is required for the test, such as a Bird Model 43, with an appropriate element installed. Before you sta ...

  • GE MDS 05-4558A01 - page 14

    05-4558A01, Rev . C MDS Mercur y Series Star tup Guide 11 TR OUBLESHOO TING It is best to begin troubleshooting at the Access Point, as the rest of the system depends on it for network synchronization and configuration. If the Access Point has problems, the operation of the entire network will be affected. All radios in the network must meet these ...

  • GE MDS 05-4558A01 - page 15

    12 MDS Mercur y Series Star tup Guide 05-4558A01, Rev . C LINK LED not lit. a. Network Names of APs and Remotes do not match. They must be identical for association to occur—Also, verify that the system has a unique Network Name. b. Remote not yet associated with an Access Point with the same Network Name. Check the “Status” of the unit’s p ...

  • GE MDS 05-4558A01 - page 16

    05-4558A01, Rev . C MDS Mercur y Series Star tup Guide 13 Table 2. Troubleshooting with the Menu System Symptom Problem/Recommended System Checks Cannot Access the Remote or AP through COM1 Only occurs in three possible scenarios: —COM1 is damaged or the Unit is faulty. —COM1 is being used for Streaming GPS information to Console terminal. —C ...

  • GE MDS 05-4558A01 - page 17

    14 MDS Mercur y Series Star tup Guide 05-4558A01, Rev . C SPECIFICA TIONS GENERAL Temperature Range: –40° C to +70° C (–40° F to 158° F) Humidity: 95% at +40° C (104° F); non-condensing Primary Power: 10–30 Vdc External Power Supply Options: 48 Vdc; 110–120/210–220 Vac Typical Current Consumption (assumes 1 Watt RF Output): Size (wi ...

  • GE MDS 05-4558A01 - page 18

    05-4558A01, Rev . C MDS Mercur y Series Star tup Guide 15 PHYSICAL INTERFACE : Ethernet: 10/100BaseT, RJ-45 Serial: (COM1) RS-232, DB-9F APPROVALS: FCC Part 15.247 (DTS) CSA /US Class 1, Div. 2 Industry Canada RS-210 PROTOCOLS: Ethernet: IEEE 802.3, Spanning Tree (Bridging), VLAN, IGMP TCP/IP: DHCP, ICMP, UDP, TCP. ARP, Multicast, SNTP, TFTP Serial ...

  • GE MDS 05-4558A01 - page 19

    16 MDS Mercur y Series Star tup Guide 05-4558A01, Rev . C TECHNICAL ASSIST ANCE Technical assistance is available from our Technical Support Depart- ment during business hours (8:30 A.M.–7:00 P.M. Eastern Time). When calling, please give the complete model number of the radio, along with a description of the trouble symptom(s) that you are expe- ...

  • GE MDS 05-4558A01 - page 20

    GE MDS, LLC Rochester, NY 14620 General Business: +1 585 242-9600 FAX: +1 585 242-9620 Web: www.GEmds.com 175 Science Parkway ...

Производитель GE Категория Network Router

Документы, которые мы получаем от производителя устройства GE MDS 05-4558A01 мы можем разделить на несколько групп. Это в частности:
- технические чертежи GE
- инструкции обслуживания MDS 05-4558A01
- паспорта изделия GE
- информационные брошюры
- энергетические этикетки GE MDS 05-4558A01
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания GE MDS 05-4558A01.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа GE MDS 05-4558A01, инструкции обслуживания, короткие инструкции или инструкции пользователя GE MDS 05-4558A01. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия GE MDS 05-4558A01.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства GE MDS 05-4558A01, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании GE MDS 05-4558A01 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей GE MDS 05-4558A01.

Полная инструкция обслуживания GE, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией GE MDS 05-4558A01 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания GE MDS 05-4558A01, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся GE MDS 05-4558A01, которое найдем в данном документе
3. Советы по использованию основных функций устройства GE MDS 05-4558A01 - которые должны облегчить нам первые шаги во время использования GE MDS 05-4558A01
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем GE MDS 05-4558A01
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра GE MDS 05-4558A01 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся GE MDS 05-4558A01?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с GE MDS 05-4558A01, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с GE MDS 05-4558A01 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)