Manuale per l’uso Wasp CCD - 80SIR

24 pagine 0.75 mb
Scarica

Vai alla pagina of 24

Summary
  • Wasp CCD - 80SIR - page 1

    CONFIGURATION MANUAL Bar Code Scanner 12345 67890 05 CCD - 80SIR Configuration Commands START To begin the configuration procedures END To finish the configuration procedures and save new parameters in memory. ABORT To give up all parameters that you have just selected. SET To make all parameters back to default settings with * in this manual. ...

  • Wasp CCD - 80SIR - page 2

    Configuration Commands START To begin the configuration procedures END To finish the configuration procedures and save new parameters in memory. ABORT To give up all parameters that you have just selected. SET To make all parameters back to default settings with * in this manual. Configuration Procedures START Configuration Interface Type Settings ...

  • Wasp CCD - 80SIR - page 3

    TABLE OF CONTENTS 1.1 Default Configuration 1.2 Custom Configuration 1.3 Configuration Procedures CHAPTER 2 INTERFACE SETTING 2.1 Keyboard Wedge Parameters 2.2 RS-232C Parameters CHAPTER 3 BAR CODE SETTING 3.1 Code 39 Parameters 3.2 Interleave 2 of 5 Parameters (ITF2/5) 3.3 Industrial 2 of 5 Parameters ( IND2/5) 3.4 Matrix 2 of 5 Parameters (MTX 2/ ...

  • Wasp CCD - 80SIR - page 4

    USER'S MANUAL BAR CODE SCANNER 12345 67890 05 Using the CCD Scanner There are several scanning modes within the CCD scanner for you to choose in order to suit your application. Please refer to the configuration manual for a proper selection. Here are some suggestions about the way to hold the scanner, in CCD-80SIR with no trigger, you may usin ...

  • Wasp CCD - 80SIR - page 5

    Installation The CCD scanner can be easily interfaced to a keyboard or a serial port to your computer. Now follow the procedures below for a proper installation. On your first time installation, it is necessary to select a compatible computer type. (See the configuration manual for the correct type.) To install the scanner as keyboard wedge: 1) 2) ...

  • Wasp CCD - 80SIR - page 6

    Testing the Symbologies Troubleshooting List If you have installed the CCD scanner, please try to read the following barcodes to make sure your scanner is operating properly. 12345 67890 05 783491 08 UPC-A UPC-E 2468 1353 712345 678900 4 EAN-8 EAN-13 ABCDE Code 39 123456 Interleaved 2 of 5 0123456 Codabar 123456789 Code 128 The CCD scanner automati ...

  • Wasp CCD - 80SIR - page 7

    Affixing the CCD stand 6b 6c ...

  • Wasp CCD - 80SIR - page 8

    CHAPTER 1 INTRODUCTION This manual provides all useful information regarding configuration, custom configuration and configuration procedure. You are suggested to read all information containing herein before starting to configure your scanner. As stated, we recommend that configuration, especially custom configuration, better to be performed by ex ...

  • Wasp CCD - 80SIR - page 9

    CHAPTER 2 INTERFACE SETTING The scanner has 2 modes of communication, keyboard wedge, and RS-232C, (CCD WAND and OCIA are options.) Keyboard Wedge Computer Type 2.1 Keyboard Wedge Parameters The keyboard wedge is convenient for most applications. First of all, select one of the computer type from labels below for keyboard interface. *PC/AT & PS ...

  • Wasp CCD - 80SIR - page 10

    3. Keyboard Character Delay 4. Keyboard Upper/Lower Case 5. Keyboard Number Keys 6. Keyboard Data Terminator Min. to Max:(00-99) Define char. delay=?? Note: For setting up, please refer to the examples in Chapter 5. * Lower Auto Upper * Alphanum Numeric Pad * CR SPACE ESC None TAB Ctrl + C 11 12 2. Keyboard Speed of PC/AT * Normal Turbo ...

  • Wasp CCD - 80SIR - page 11

    2.2 RS-232C Parameters The scanner also provides RS-232C interface to meet your application . Scan the label below for RS-232C interface. RS - 232C RS-232 Pin Assignment: DUSB-9P Female 1 N/C (=no connection) 2 TXD 5 GND 7 CTS 8 RTS 9 VCC (+5V) DC Adapter +5v +- 10% 150mA (min.) RS-232C parameters include: 1. Baud rate 2. Data bits 3. Parity 4. Han ...

  • Wasp CCD - 80SIR - page 12

    4. Handshaking * None Xon/Xoff RTS/CTS 5. Character Delay Min. to Max.:(00-99) Define char. delay=?? 6. Data Terminator * CR LF SPACE ESC STX/ETX None CR+LF TAB Ctrl + C Xon/Xoff 15 CHAPTER 3 BAR CODE SETTING The scanner can read almost all popular symbologies in the world. Scan one or more codes from the following labels to meet your applications. ...

  • Wasp CCD - 80SIR - page 13

    Readable Code Setting ( Cont'd) EAN-13/UPC-A EAN-8 UPC-E UPC/EAN Code 128 *On Off * On Off * On Off On * Off *On Off Standard readable codes include Code 93, Code 11, Code IV, MSI/Plessy, China Postage and ISBN/ISSN listed in page 25. Code 14 On Off Add-on 2/5 17 3.1 CODE 39 Parameters These parameters include: 1. Character set 2. Verify check ...

  • Wasp CCD - 80SIR - page 14

    19 3.2 Interleave 2 of 5 Parameters 1. Verify check digit 2. Transmit check digit 3. Code length 1. Verify Check Digit * No Yes 2. Transmit Check Digit * No Yes 3. Code Length * Variable length Min.=?? Max.=?? (4 - 48) Fixed length Custom define=??? Note: 1. Default is set to various length with minimum 4 and maximum 48. 2. In order to suit your ro ...

  • Wasp CCD - 80SIR - page 15

    21 3.4 Matrix 2 of 5 Parameters 1. Verify check digit 2. Transmit check digit 3. Code length 1. Verify Check Digit 2. Transmit Check Digit * No Yes * No Yes 3.Code Length * Variable length Min.= ?? Max.= ?? ( 2-40) Note: See examples in Chapter 5 for re-definition. Fixed length Custom define=??? 3.5 Codabar Parameters 1. Transmit start/stop charact ...

  • Wasp CCD - 80SIR - page 16

    23 1. Transmit First Digit 3.6 EAN-13 Parameters 1. Transmit first digit 2. Transmit second digit 3. Transmit check digit * Yes No 2. Transmit Second Digit *Yes No 3. Transmit Check Digit * Yes No 3.7 UPC-A Parameters 1. Transmit first digit 2. Transmit second digit 3. Transmit check digit 1. Transmit First Digit 2. Transmit Second Digit * Yes No * ...

  • Wasp CCD - 80SIR - page 17

    25 1. Transmit First Digit 2. Transmit Check Digit 3.8 EAN-8 Parameters 1. Transmit first digit 2. Transmit check digit * Yes No * Yes No 3.9 UPC-E Parameters 1. Transmit first digit 2. Transmit check digit 1. Transmit First Digit 2. Transmit Check Digit * Yes No * Yes No CHAPTER 4 OPTIONAL SETTING This chapter provides you instructions for selecti ...

  • Wasp CCD - 80SIR - page 18

    4.2 Code Mark ( Code ID) Parameters You may use the example listed below to define the code mark for your own applications. Please note that each code mark you define has to follow the steps as example shown below . You may also refer to Chapter 5 for details. For example: to define " Z " as code mark for code 39. , the steps will be as u ...

  • Wasp CCD - 80SIR - page 19

    29 4.5 Other parameters These parameters include power up tone and LED indicator. Power up Tone * On Off LED Indicator * LED on Good read off LED off Good read on 4.6 Code(S) Single or Double Read Code(S) Single Read Double Read CHAPTER 5 USEFUL EXAMPLES Here we list examples concerning configuration steps for your reference. We have illustrated th ...

  • Wasp CCD - 80SIR - page 20

    Chapter 6. USB Connection ( Optional) Scan the following command codes to complete USB setting: USB Setting 31 APPENDICES APPENDIX A. ASCII CODE TABLE START END SET 32 H L 01 2 3 4 5 67 0 NUL DLE SP 0 @ P p ` 1 SOH DC1 “2 B R b r 2 STX DC2 !1 A Q aq 3 ETX DC3 # 3 C S cs 4 EOT DC4 $ 4 D T dt 5 ENQ NAK % 5 E U eu 6 ACK SYN & 6 F V fv 7 BEL ETB ...

  • Wasp CCD - 80SIR - page 21

    33 APPENDIX B. DECIMAL TABLE H L 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 2 3 45 67 32 48 64 80 112 96 34 50 66 82 98 114 33 49 65 81 97 113 35 51 67 83 99 115 36 52 68 84 100 116 37 53 69 85 101 117 38 54 70 86 102 118 39 55 71 87 103 119 40 56 72 88 104 120 41 57 73 ...

  • Wasp CCD - 80SIR - page 22

    35 B) Keyboard Layout Italy U.K. Portugal Latin America Poland Sweden/Finland Belgium Denmark Norway Japan Holland Switzerland C) Readable Code Code 93 On * Off Code 11 On * Off MSI/Plessy On * Off China Postage On * Off Code IV On * Off ISBN/ISSN On *Off GTIN14 Ean-128 * Off ON * Off ON 36 ...

  • Wasp CCD - 80SIR - page 23

    37 D) Code 11 Parameters : 1. Number of Check Digit One Two 2. Transmit Check Digit Yes No E)Code 93 Parameters Concatenation On Off G) General Parameters- Code Mark Code Mark Parameters Code 93 MSI/Plessy Code IV Code 11 China Postage CANCEL Note: 1. Read code type ( just once a time) and then CANCEL label afterwards. F) China Postage Parameters 1 ...

  • Wasp CCD - 80SIR - page 24

    39 APPENDIX D. HEX-LABEL TABLE 0 1 2 3 4 5 6 7 8 9 A B C D E F EXIT ...

Fabbricante Wasp Categoria Automobile Electronics

I documenti che otteniamo dal fabbricante del dispositivoWasp CCD - 80SIR possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Wasp
- manuali per l’uso CCD - 80SIR
- schede prodotto Wasp
- opuscoli
- o etichette energetiche Wasp CCD - 80SIR
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Wasp CCD - 80SIR.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Wasp CCD - 80SIR, manuali di manutenzione, brevi manuali o manuali utente Wasp CCD - 80SIR. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Wasp CCD - 80SIR.

Manuali per l’uso simili

Manuale completo del dispositivo Wasp CCD - 80SIR, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Wasp CCD - 80SIR dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Wasp CCD - 80SIR.

Il manuale per l’uso completo Wasp, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Wasp CCD - 80SIR - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Wasp CCD - 80SIR, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Wasp CCD - 80SIR che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Wasp CCD - 80SIR - che ci dovrebbe aiutare nei primi passi durante l'uso Wasp CCD - 80SIR
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Wasp CCD - 80SIR
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Wasp CCD - 80SIR in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Wasp CCD - 80SIR?

Utilizza il modulo sottostante

Se non hai risolto il problema con Wasp CCD - 80SIR con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Wasp CCD - 80SIR è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)