    CONFIGURATION MANUAL Bar Code Scanner 12345 67890 05 CCD - 80SIR Configuration Commands START To begin the configuration procedures END To finish the configuration procedures and save new parameters in memory. ABORT To give up all parameters that you have just selected. SET To make all parameters back to default settings with * in this manual. ...

  • Wasp CCD - 80SIR - page 2

    Configuration Commands START To begin the configuration procedures END To finish the configuration procedures and save new parameters in memory. ABORT To give up all parameters that you have just selected. SET To make all parameters back to default settings with * in this manual. Configuration Procedures START Configuration Interface Type Settings ...

  • Wasp CCD - 80SIR - page 3

    TABLE OF CONTENTS 1.1 Default Configuration 1.2 Custom Configuration 1.3 Configuration Procedures CHAPTER 2 INTERFACE SETTING 2.1 Keyboard Wedge Parameters 2.2 RS-232C Parameters CHAPTER 3 BAR CODE SETTING 3.1 Code 39 Parameters 3.2 Interleave 2 of 5 Parameters (ITF2/5) 3.3 Industrial 2 of 5 Parameters ( IND2/5) 3.4 Matrix 2 of 5 Parameters (MTX 2/ ...

  • Wasp CCD - 80SIR - page 4

    USER'S MANUAL BAR CODE SCANNER 12345 67890 05 Using the CCD Scanner There are several scanning modes within the CCD scanner for you to choose in order to suit your application. Please refer to the configuration manual for a proper selection. Here are some suggestions about the way to hold the scanner, in CCD-80SIR with no trigger, you may usin ...

  • Wasp CCD - 80SIR - page 5

    Installation The CCD scanner can be easily interfaced to a keyboard or a serial port to your computer. Now follow the procedures below for a proper installation. On your first time installation, it is necessary to select a compatible computer type. (See the configuration manual for the correct type.) To install the scanner as keyboard wedge: 1) 2) ...

  • Wasp CCD - 80SIR - page 6

    Testing the Symbologies Troubleshooting List If you have installed the CCD scanner, please try to read the following barcodes to make sure your scanner is operating properly. 12345 67890 05 783491 08 UPC-A UPC-E 2468 1353 712345 678900 4 EAN-8 EAN-13 ABCDE Code 39 123456 Interleaved 2 of 5 0123456 Codabar 123456789 Code 128 The CCD scanner automati ...

  • Wasp CCD - 80SIR - page 7

    Affixing the CCD stand 6b 6c ...

  • Wasp CCD - 80SIR - page 8

    CHAPTER 1 INTRODUCTION This manual provides all useful information regarding configuration, custom configuration and configuration procedure. You are suggested to read all information containing herein before starting to configure your scanner. As stated, we recommend that configuration, especially custom configuration, better to be performed by ex ...

  • Wasp CCD - 80SIR - page 9

    CHAPTER 2 INTERFACE SETTING The scanner has 2 modes of communication, keyboard wedge, and RS-232C, (CCD WAND and OCIA are options.) Keyboard Wedge Computer Type 2.1 Keyboard Wedge Parameters The keyboard wedge is convenient for most applications. First of all, select one of the computer type from labels below for keyboard interface. *PC/AT & PS ...

  • Wasp CCD - 80SIR - page 10

    3. Keyboard Character Delay 4. Keyboard Upper/Lower Case 5. Keyboard Number Keys 6. Keyboard Data Terminator Min. to Max:(00-99) Define char. delay=?? Note: For setting up, please refer to the examples in Chapter 5. * Lower Auto Upper * Alphanum Numeric Pad * CR SPACE ESC None TAB Ctrl + C 11 12 2. Keyboard Speed of PC/AT * Normal Turbo ...

  • Wasp CCD - 80SIR - page 11

    2.2 RS-232C Parameters The scanner also provides RS-232C interface to meet your application . Scan the label below for RS-232C interface. RS - 232C RS-232 Pin Assignment: DUSB-9P Female 1 N/C (=no connection) 2 TXD 5 GND 7 CTS 8 RTS 9 VCC (+5V) DC Adapter +5v +- 10% 150mA (min.) RS-232C parameters include: 1. Baud rate 2. Data bits 3. Parity 4. Han ...

  • Wasp CCD - 80SIR - page 12

    4. Handshaking * None Xon/Xoff RTS/CTS 5. Character Delay Min. to Max.:(00-99) Define char. delay=?? 6. Data Terminator * CR LF SPACE ESC STX/ETX None CR+LF TAB Ctrl + C Xon/Xoff 15 CHAPTER 3 BAR CODE SETTING The scanner can read almost all popular symbologies in the world. Scan one or more codes from the following labels to meet your applications. ...

  • Wasp CCD - 80SIR - page 13

    Readable Code Setting ( Cont'd) EAN-13/UPC-A EAN-8 UPC-E UPC/EAN Code 128 *On Off * On Off * On Off On * Off *On Off Standard readable codes include Code 93, Code 11, Code IV, MSI/Plessy, China Postage and ISBN/ISSN listed in page 25. Code 14 On Off Add-on 2/5 17 3.1 CODE 39 Parameters These parameters include: 1. Character set 2. Verify check ...

  • Wasp CCD - 80SIR - page 14

    19 3.2 Interleave 2 of 5 Parameters 1. Verify check digit 2. Transmit check digit 3. Code length 1. Verify Check Digit * No Yes 2. Transmit Check Digit * No Yes 3. Code Length * Variable length Min.=?? Max.=?? (4 - 48) Fixed length Custom define=??? Note: 1. Default is set to various length with minimum 4 and maximum 48. 2. In order to suit your ro ...

  • Wasp CCD - 80SIR - page 15

    21 3.4 Matrix 2 of 5 Parameters 1. Verify check digit 2. Transmit check digit 3. Code length 1. Verify Check Digit 2. Transmit Check Digit * No Yes * No Yes 3.Code Length * Variable length Min.= ?? Max.= ?? ( 2-40) Note: See examples in Chapter 5 for re-definition. Fixed length Custom define=??? 3.5 Codabar Parameters 1. Transmit start/stop charact ...

  • Wasp CCD - 80SIR - page 16

    23 1. Transmit First Digit 3.6 EAN-13 Parameters 1. Transmit first digit 2. Transmit second digit 3. Transmit check digit * Yes No 2. Transmit Second Digit *Yes No 3. Transmit Check Digit * Yes No 3.7 UPC-A Parameters 1. Transmit first digit 2. Transmit second digit 3. Transmit check digit 1. Transmit First Digit 2. Transmit Second Digit * Yes No * ...

  • Wasp CCD - 80SIR - page 17

    25 1. Transmit First Digit 2. Transmit Check Digit 3.8 EAN-8 Parameters 1. Transmit first digit 2. Transmit check digit * Yes No * Yes No 3.9 UPC-E Parameters 1. Transmit first digit 2. Transmit check digit 1. Transmit First Digit 2. Transmit Check Digit * Yes No * Yes No CHAPTER 4 OPTIONAL SETTING This chapter provides you instructions for selecti ...

  • Wasp CCD - 80SIR - page 18

    4.2 Code Mark ( Code ID) Parameters You may use the example listed below to define the code mark for your own applications. Please note that each code mark you define has to follow the steps as example shown below . You may also refer to Chapter 5 for details. For example: to define " Z " as code mark for code 39. , the steps will be as u ...

  • Wasp CCD - 80SIR - page 19

    29 4.5 Other parameters These parameters include power up tone and LED indicator. Power up Tone * On Off LED Indicator * LED on Good read off LED off Good read on 4.6 Code(S) Single or Double Read Code(S) Single Read Double Read CHAPTER 5 USEFUL EXAMPLES Here we list examples concerning configuration steps for your reference. We have illustrated th ...

  • Wasp CCD - 80SIR - page 20

    Chapter 6. USB Connection ( Optional) Scan the following command codes to complete USB setting: USB Setting 31 APPENDICES APPENDIX A. ASCII CODE TABLE START END SET 32 H L 01 2 3 4 5 67 0 NUL DLE SP 0 @ P p ` 1 SOH DC1 “2 B R b r 2 STX DC2 !1 A Q aq 3 ETX DC3 # 3 C S cs 4 EOT DC4 $ 4 D T dt 5 ENQ NAK % 5 E U eu 6 ACK SYN & 6 F V fv 7 BEL ETB ...

  • Wasp CCD - 80SIR - page 21

    33 APPENDIX B. DECIMAL TABLE H L 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 2 3 45 67 32 48 64 80 112 96 34 50 66 82 98 114 33 49 65 81 97 113 35 51 67 83 99 115 36 52 68 84 100 116 37 53 69 85 101 117 38 54 70 86 102 118 39 55 71 87 103 119 40 56 72 88 104 120 41 57 73 ...

  • Wasp CCD - 80SIR - page 22

    35 B) Keyboard Layout Italy U.K. Portugal Latin America Poland Sweden/Finland Belgium Denmark Norway Japan Holland Switzerland C) Readable Code Code 93 On * Off Code 11 On * Off MSI/Plessy On * Off China Postage On * Off Code IV On * Off ISBN/ISSN On *Off GTIN14 Ean-128 * Off ON * Off ON 36 ...

  • Wasp CCD - 80SIR - page 23

    37 D) Code 11 Parameters : 1. Number of Check Digit One Two 2. Transmit Check Digit Yes No E)Code 93 Parameters Concatenation On Off G) General Parameters- Code Mark Code Mark Parameters Code 93 MSI/Plessy Code IV Code 11 China Postage CANCEL Note: 1. Read code type ( just once a time) and then CANCEL label afterwards. F) China Postage Parameters 1 ...

  • Wasp CCD - 80SIR - page 24

    39 APPENDIX D. HEX-LABEL TABLE 0 1 2 3 4 5 6 7 8 9 A B C D E F EXIT ...

メーカー Wasp カテゴリー Automobile Electronics

Wasp CCD - 80SIRのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- CCD - 80SIRの取扱説明書
- Waspの製品カード
- パンフレット
- またはWasp CCD - 80SIRの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Wasp CCD - 80SIRの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Wasp CCD - 80SIRの取り付け説明書、サービスマニュアル、簡易説明書、またはWasp CCD - 80SIRのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Wasp CCD - 80SIRの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Wasp CCD - 80SIRデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがWasp CCD - 80SIRを使用するのを助ける技術的文書のことです。説明書は通常、全てのWasp CCD - 80SIRユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Waspの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Wasp CCD - 80SIRの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははWasp CCD - 80SIRの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Wasp CCD - 80SIRに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Wasp CCD - 80SIRデバイスの基本機能を使うにあたってのヒント。 Wasp CCD - 80SIRのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Wasp CCD - 80SIRに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるWasp CCD - 80SIRのメーカー/サービスへの連絡先に関する情報。

Wasp CCD - 80SIRについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもWasp CCD - 80SIRの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがWasp CCD - 80SIRで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)