Manuale per l’uso IDEAL INDUSTRIES 61-095

13 pagine 0.51 mb
Scarica

Vai alla pagina of 13

Summary
  • IDEAL INDUSTRIES 61-095 - page 1

    IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-095 The Service Informatio n provides the fo llowing informa tion: • Precautions and safety inform ation • Specifications • Performance test procedure • Calibrati on and calibration adjustm ent procedure • Basic maintenance (cl eaning, replaci ng the battery) Form num ber: TM61095 Revision ...

  • IDEAL INDUSTRIES 61-095 - page 2

    TABLE OF CONTENTS Title Page # Introduction 1 Precautions and Safety Information 1 Symbols 1 Safety 2 Specifications 3 General Specification 3 Voltage Specifications 4 Resistance and C ontinuity Specifications 4 Current Specifications 4 Physical and environment characteristics 5 Certification and compliance 5 Required Equipm ent 6 Basic Maintenance ...

  • IDEAL INDUSTRIES 61-095 - page 3

    Page 1 Introduction Warning To avoid shock or injury, do not perform the verification tests or cali bration procedures described in this manual unless you are qualified to do so. The information provided in this document is for the use of qualified personnel only. Caution The 61-095 contains parts that can be damaged by static discharge. Follow the ...

  • IDEAL INDUSTRIES 61-095 - page 4

    Page 2 SAFETY Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. To avoid potential h azards, use the product only as specified. CAUTION. These statements identify conditions or practices that cou ld result in damage to the equipment or other property. WARNING. These statement ...

  • IDEAL INDUSTRIES 61-095 - page 5

    Page 3 SPECIFICATIONS All specifications are warrant ed unless noted typical and appl y to the 61-095. Stated accuracies are at 23º C ± 5ºC at less than 80% relative humidity and without the battery indicator display ed. General specifications Characteristics Description LCD display digi ts 3 ½ Display count 2,000 Numeric update rat e 2.5 times ...

  • IDEAL INDUSTRIES 61-095 - page 6

    Page 4 Measurement Characteristics Accuracy is ±(% reading + num ber of digits) at 2 3ºC ± 5º C, less than 80% R .H. Voltage Function Range Accuracy Overload protection V 600 Vrms ± (1.5%+ 3 dgt) 40Hz ~ 500Hz 600 Vrm s V 600 V ± (1% + 2 dgt) Input impedance: 1M Ω // less than 100pF. Resistance & Continuity Function Range Accuracy Overlo ...

  • IDEAL INDUSTRIES 61-095 - page 7

    Page 5 Physical and Environmental Characteristi cs Physical Characteristics Description Dimensi ons (H x W x D) 188mm x 66mm x 42mm Weight (with battery) 0.3Kg Environmental Characteristics Description Temperature operating 0 to + 50º C Non-Operating -20 to + 60º C Humidit y (operating) < 80% R.H. Altitude Operating 2,000 m (6560 ft.) Non-Oper ...

  • IDEAL INDUSTRIES 61-095 - page 8

    Page 6 Required Equipment Required equipment is listed in Tab le B. If the recommended m odels are no t available, equ ipment with equivalent specifications m ay be used. Repairs or servicing s hould be perform ed only by qualified personnel. Table B. Required Equipment Equipment Required Characteristics Recommended Model Calibrator AC Voltage Rang ...

  • IDEAL INDUSTRIES 61-095 - page 9

    Page 7 Basic Maintenance Warning To avoid shock, remove the te st leads and any input signal s before opening the case or replacing the battery or fuses. Opening the Meter Case Caution To avoid unintentional short circu it, always place the uncovered meter assembly on a protective surface. When the case of the meter is open, circuit connections are ...

  • IDEAL INDUSTRIES 61-095 - page 10

    Page 8 Performance Tests The following perform ance tests verify the complete ope rability of the meter and check the accuracy of each meter function against the meter’s specifications. Accuracy specifications are valid for a period of one year after cali bration, when measured at an operat ing temp er atu re o f 18 ºC to 28ºC and at a maximum ...

  • IDEAL INDUSTRIES 61-095 - page 11

    Page 9 Testing the Resistance Function To verify the accuracy of the re sistance function, do the following: 1. Connect the calib rator to V Ω and COM on the meter. 2. Turn the rotary switch to Ω . 3. Apply the inputs for step 1-4 i n Table 3. 4. Compare the meter display readings to the display reading s in Table 3. 5. If the display reading f ...

  • IDEAL INDUSTRIES 61-095 - page 12

    Page 10 OK Figure 2 Top shows correct method; bo ttom shows incorrect method. Calibration Calibrate the meter once a year to ensure that it perform s according to specifications. Per fo rm ca lib ra tio n at an a mbi ent t empe ra tu re o f 23ºC ± 2ºC and relative humidity of 75% or less. Calibration for the Model 61-095: 1. Disconnect the test ...

  • IDEAL INDUSTRIES 61-095 - page 13

    Form number TM61095 Rev 2 September 2002 Page 11 Figure 3 - Calibration Adjustment Points ...

Fabbricante IDEAL INDUSTRIES Categoria Power Hammer

I documenti che otteniamo dal fabbricante del dispositivoIDEAL INDUSTRIES 61-095 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici IDEAL INDUSTRIES
- manuali per l’uso 61-095
- schede prodotto IDEAL INDUSTRIES
- opuscoli
- o etichette energetiche IDEAL INDUSTRIES 61-095
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso IDEAL INDUSTRIES 61-095.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione IDEAL INDUSTRIES 61-095, manuali di manutenzione, brevi manuali o manuali utente IDEAL INDUSTRIES 61-095. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto IDEAL INDUSTRIES 61-095.

Manuale completo del dispositivo IDEAL INDUSTRIES 61-095, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare IDEAL INDUSTRIES 61-095 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti IDEAL INDUSTRIES 61-095.

Il manuale per l’uso completo IDEAL INDUSTRIES, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale IDEAL INDUSTRIES 61-095 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice IDEAL INDUSTRIES 61-095, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per IDEAL INDUSTRIES 61-095 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo IDEAL INDUSTRIES 61-095 - che ci dovrebbe aiutare nei primi passi durante l'uso IDEAL INDUSTRIES 61-095
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del IDEAL INDUSTRIES 61-095
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio IDEAL INDUSTRIES 61-095 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su IDEAL INDUSTRIES 61-095?

Utilizza il modulo sottostante

Se non hai risolto il problema con IDEAL INDUSTRIES 61-095 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con IDEAL INDUSTRIES 61-095 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)