Manuale per l’uso Honeywell DC300K-E

12 pagine 0.14 mb
Scarica

Vai alla pagina of 12

Summary
  • Honeywell DC300K-E - page 1

    Industrial Automation and Control, 110 Virginia Drive, Fort Washington, PA 19034 Printed in U.S.A. ■  Copyright 1997 Honeywell Inc. UDC3000 Versa-Pro Universal Digital Controller 51-52-03-07 2/97 Page 1 of 12 Specification Overview The UDC3000 Universal Digital Controller is Honeywell’s general purpose microprocessor-based, stand alone digit ...

  • Honeywell DC300K-E - page 2

    51-52-03-07 Page 2 Features, continued CE Mark- Conformity with 73/23/EEC, Low Voltage Directive and 89/336/EEC, the EMC Directive Moisture Resistant Front Panel - Capable of meeting NEMA 3 and IEC529 IP65 (i.e. hosedown) requirements. Timer - This standard feature pro- vides a configurable time period of 0 to 99 hours, 59 minutes. Alarm 1 is dedic ...

  • Honeywell DC300K-E - page 3

    51-52-03-07 Page 3 Output Types The following output types are available per the model selection guide: • Current output • Electromechanical relays • Solid state relays • Open collector output • Solid state relay (10 amp) externally mounted (optional) • Auxiliary current output (optional) Output Algorithms The UDC3000 is available with ...

  • Honeywell DC300K-E - page 4

    51-52-03-07 Page 4 ALM RSP OUT % 1 2 1 2 1 2 F C MAN FUNCTION SET UP LOWER DISPLAY MANUAL AUTO SETPOINT SELECT RUN HOLD DI Indicator definition when lit ALM - Alarm conditions exist DI - Digital Input active OUT - Control Relay 1 or 2 on Upper Display - Six Characters • Normal Operation - four digits dedicated to display the process variable • ...

  • Honeywell DC300K-E - page 5

    51-52-03-07 Page 5 Specifications Design CE Conformity (Europe) This product is in conformity with the protection requirements of the following European Council Directives: 73/23/EEC , the Low Voltage Directive, and 89/336/EEC , the EMC Directive. Conformity of this product with any other “CE Mark” Directive(s) shall not be assumed. Product Cla ...

  • Honeywell DC300K-E - page 6

    51-52-03-07 Page 6 Specifications (continued) Design (continued) Controller Output Types Current Output (Isolated) Range can be set anywhere between 0 to 21 mA, and as direct or reverse action. Resolution: 11 bits for 0 to 21 mA Accuracy: 0.5% full scale Temperature Stability: 0.1% F.S. / ˚C Load Resistance: 0 to 1000 ohms Electromechanical Relays ...

  • Honeywell DC300K-E - page 7

    51-52-03-07 Page 7 Specifications (continued) Design (continued) Auxiliary Linear Output (Optional) (Isolated) 21 mA dc maximum into a negative or positive grounded load or non-grounded load of 0 to 1000 ohms. Output range can be set anywhere between 0 to 21 mA, and as direct or reverse action. It can be configured to represent either Input, PV, Se ...

  • Honeywell DC300K-E - page 8

    51-52-03-07 Page 8 Specifications (continued) Environmental and Operating Conditions Parameter Reference Rated Operative Limits Transportation and storage Ambient Temperature 25 ± 3 ˚ C 77 ± 5 ˚ F 15 to 55 ˚ C 58 to 131 ˚ F 0 to 55 ˚ C 32 to 131 ˚ F -40 to 66 ˚ C -40 to 151 ˚ F Relative Humidity 10 to 55* 10 to 90* 5 to 90* 5 to 95* Vibra ...

  • Honeywell DC300K-E - page 9

    51-52-03-07 Page 9 General Reference Data Data Isolation (Functional) AC Power : is electrically isolated from all other inputs and outputs to withstand a HIPOT potential of 1900Vdc for 2 seconds per Annex K of EN61010-1. Analog Inputs and Outputs: are isolated from each other and all other circuits at 850Vdc for 2 seconds. Digital Input and Digita ...

  • Honeywell DC300K-E - page 10

    51-52-03-07 Page 10 Dimensions Panel Cutout ALM RSP OUT % 1 2 1 2 F C MAN PV 1 2 3 4 96 3.780 AL M % 1 2 1 2 1 2 F C M A N DI ALM RSP OUT % 1 2 1 2 F C MAN DI FUNCTION LOWER DISPLAY MANUAL AUTO SETPOINT SELECT SET UP HOLD 1 2 24 .945 Max Panel Thickness 10 .394 Max (2) 5.82 147.3 21.6 .850 .093 2.4 with optional rear cover 90.7 3.57 22073 +0.008 92 ...

  • Honeywell DC300K-E - page 11

    51-52-03-07 Page 11 Wiring Diagram 1 2 3 4 5 6 7 8 9 ALM 1 CTL 2 ALM 2 CTL 1 4-20 MA 10 11 12 13 14 15 16 17 DI 1 TX- or AUX- TX+ or AUX+ RX-/TX- RX+/TX+ SHIELD DI 2 UDC 3000 EXTERNAL WIRING L1/H L2/N 22 23 24 25 26 27 IN 1 IN 2 0 Instrument Power 22840 NOTE: The product manual should be consulted for specific details and precautions regarding wiri ...

  • Honeywell DC300K-E - page 12

    51-52-03-07 Page 12 Ordering Information For the complete ordering information, request Model Selection Guide: 51-51-16-32 for UDC3000 Universal Digital Controller or . . Honeywell offers a full Iine of Sensors, Transmitters, and Final Control Devices for use with the UDC3000 Universal Digital Controller. These devices include: Thermocouples, RTDs ...

Fabbricante Honeywell Categoria Universal Remote

I documenti che otteniamo dal fabbricante del dispositivoHoneywell DC300K-E possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Honeywell
- manuali per l’uso DC300K-E
- schede prodotto Honeywell
- opuscoli
- o etichette energetiche Honeywell DC300K-E
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Honeywell DC300K-E.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Honeywell DC300K-E, manuali di manutenzione, brevi manuali o manuali utente Honeywell DC300K-E. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Honeywell DC300K-E.

Manuali per l’uso simili

Manuale completo del dispositivo Honeywell DC300K-E, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Honeywell DC300K-E dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Honeywell DC300K-E.

Il manuale per l’uso completo Honeywell, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Honeywell DC300K-E - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Honeywell DC300K-E, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Honeywell DC300K-E che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Honeywell DC300K-E - che ci dovrebbe aiutare nei primi passi durante l'uso Honeywell DC300K-E
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Honeywell DC300K-E
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Honeywell DC300K-E in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Honeywell DC300K-E?

Utilizza il modulo sottostante

Se non hai risolto il problema con Honeywell DC300K-E con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Honeywell DC300K-E è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)