    15 Liberty St., Metuchen NJ 08840 1-800-LAB-SPEX (1-800-522-7739) ext 465 6870 FREEZER/MILL ® OPERATING MANUAL This manual is part number 85018 ...

  • Allied Telesis 6870 - page 2

    Page 2 of 25 SPEX SamplePrep LLC 9.24.07 TABLE OF CONTENTS SECTION DESCRIPTION PAGE 1.0 Introd uction .................................................................................................................................. 3 2.0 Specif icati ons .............................................................................................. ...

  • Allied Telesis 6870 - page 3

    Page 3 of 25 SPEX SamplePrep LLC 9.24.07 SECTION 1.0: INTRODUCTION SPEX SamplePrep Freezer/ Mills are cryogenic laboratory mills that cool samples to cryogenic temperatures, and pulverize them by m agnetically shuttling a steel impactor back and forth against two stationary end plugs. Since the vial is closed, the integrity o f its contents is main ...

  • Allied Telesis 6870 - page 4

    Page 4 of 25 SPEX SamplePrep LLC 9.24.07 SECTION 2.0: 6870 FREEZER/MILL SPECIFICATIONS Type of mill: cryogenic impact mill Grinding mechanism: steel im pactor driven by dual electromagnets Coolant: liquid nitrogen Weight (empty, without vial or coolant): a pprox. 44 lbs. (20 Kg) Grinding Vials: one 6801 Large Vial, one Mid-Size Vial (6871, 6881, 68 ...

  • Allied Telesis 6870 - page 5

    Page 5 of 25 SPEX SamplePrep LLC 9.24.07 SECTION 3.0: UNPACKING Inspect the exterior of the packing box and repor t any visible damage to the carrier. Remove all packing documents from the exterior of the box, a nd save them for your records. Open the top of the shipping box. Remove the packing material and accessories, and gen tly remove the Freez ...

  • Allied Telesis 6870 - page 6

    Page 6 of 25 SPEX SamplePrep LLC 9.24.07 6870 FREEZER/MILL, BACK VIEW SECTION 4: SETTING UP The 6870 Freezer/Mill weighs 44 pounds (20 Kg) empty. The lid opens fro m the front and the lid latch is in the center. The AC Input module is on the back of the cab inet, and includes the power switch and fuse tray. The fuse tray can be opened with small sc ...

  • Allied Telesis 6870 - page 7

    Page 7 of 25 SPEX SamplePrep LLC 9.24.07 The control panel is a touch-screen, activated by a stylus. The Freezer/Mill is progra mmed and operated through this control panel, whose successive screens are described and illustrated in Section 5, starting on page 8. Programmable parame ters include pre-cooling time, grinding tim e, cooling time between ...

  • Allied Telesis 6870 - page 8

    Page 8 of 25 SPEX SamplePrep LLC 9.24.07 4.4 Grinding Vial Sizes, Adapters, and Vial Openers. Large vials (6801, 6871) are run one at a time in the 6870 Freezer/Mill, w ithout any adapter. Large vials are opened by the 6804 Extractor/Vial Opener, which is p art of the 6870L Accessory Package. Mid-Size vials (6881, 6883, 6885) ar e run one at a time ...

  • Allied Telesis 6870 - page 9

    Page 9 of 25 SPEX SamplePrep LLC 9.24.07 SECTION 5.0: TOUCHSCREEN DISPLAYS The 6870 Freezer/Mill is programmed and operated through a series of touchscreen displays. Transition between screens, a nd all programming and operating commands, are done by touching the screen with a stylus. D o not use a sharp point as this can damage or deface the scree ...

  • Allied Telesis 6870 - page 10

    Page 10 of 25 SPEX SamplePrep LLC 9.24.07 6) Third cycle: the coil is activated for the final 2-minute cycle. When it is done, the program is over and the sample has been ground for a total of 6 m inutes. 5.3 STATUS SCREEN To run the program displayed on the CURRENT SETTINGS screen, touch “Start SCRN.” This transfers you to the STATUS screen, w ...

  • Allied Telesis 6870 - page 11

    Page 11 of 25 SPEX SamplePrep LLC 9.24.07 During the PRECOOL stage the TIME REMAINING line co unts down the time for that stage in 5-second increments: 4:45, 4:40, 4:35, etc. After the PRECOOL stage comes the first GRINDI NG stage, and the screen displays STATUS: GRINDING. The TIME REMAINING line will displa y the time left in that grinding stage. ...

  • Allied Telesis 6870 - page 12

    Page 12 of 25 SPEX SamplePrep LLC 9.24.07 impactor strikes both ends of the vial, a rate of 10 represents 20 impacts per second. T he factory default setting for the rate is 10, and any saved program w ill revert to a rate of 10. To stop a program, touch STOP. The program will end. If RUN is pressed the entire program will start over. To pause duri ...

  • Allied Telesis 6870 - page 13

    Page 13 of 25 SPEX SamplePrep LLC 9.24.07 To store the new program on the CURRENT SETTINGS screen, or to recall a stored program to override the new program, touch STO/RCL to take you to the first of two STORE/RECALL screens: 5.5 STORE/RECALL SCREENS Rcl Sto PRESET O: FISH SCALES Lbl Rcl Sto PRESET 1: Lbl Rcl Sto PRESET 2: Lbl Rcl Sto PRESET 3: Lbl ...

  • Allied Telesis 6870 - page 14

    Page 14 of 25 SPEX SamplePrep LLC 9.24.07 As you touch the letter/number keys, what you ha ve entered appears above the keyboard in a mini-screen with a centered cursor. The SHIFT key lets you shift back and forth from upper case to lower case. Touching the SPACE key advances the cursor one space. Touching the BACK key sends th e cursor back one sp ...

  • Allied Telesis 6870 - page 15

    Page 15 of 25 SPEX SamplePrep LLC 9.24.07 Note that there are three different sizes of vial that can be ru n in the 6870 Freeze r/Mill: Large, Mid-Size, and Small. Mid-Size vials must be run with a 6886 Adapter in the coil, and Sm all vials must be run with a 6806 Adapter in the coil. Large vials do not need an Adapter. See Section 4.4 for details. ...

  • Allied Telesis 6870 - page 16

    Page 16 of 25 SPEX SamplePrep LLC 9.24.07 procedure for your own materials should be dete rm ined by trials; in practice almost no two materials grind alike. Avoid overfilling vials as this greatly reduces grinding efficiency. If at first the sample doesn’t gri nd as intended, try these strategies: • Reduce the overall weight of the sample. (So ...

  • Allied Telesis 6870 - page 17

    Page 17 of 25 SPEX SamplePrep LLC 9.24.07 Accessory Packs can be placed in an insulated container to hold the v ials upright during chilling. At the same time, chill an im pactor separately. As soon as the submerged end of the vial is chilled, drop in the cold sam ple and then the chilled impactor. (Always wear insulated gloves when handling chille ...

  • Allied Telesis 6870 - page 18

    Page 18 of 25 SPEX SamplePrep LLC 9.24.07 6.32 Opening the Vials To open a vial, slip the open end of the appropr iate Extracto r/Vial Opener over a threaded end- plug, align the pegs in the end-plug with the sl ots in the Extractor, and turn the knob clockwise until the end-plug is drawn out. If the end-plug is drawn out within a m illimeter or tw ...

  • Allied Telesis 6870 - page 19

    Page 19 of 25 SPEX SamplePrep LLC 9.24.07 The impactor will have to be separated from the sample and can be handled with gloved fingers, a strong magnet, tongs, or pliers. Tools without a good gripping surface are li kely to slip off the impactor. If some condensation on a cold sam ple is unaccept able, you can either wait for the sample vial to wa ...

  • Allied Telesis 6870 - page 20

    Page 20 of 25 SPEX SamplePrep LLC 9.24.07 6.4 Checking The Liquid Nitrogen Level Every time you remove or insert a vial, note the le vel of liquid nitrogen (LN) in the tub. You should top off the LN when needed as a matter of routine. If your programmed grinding cycle includes more than twenty or th irty minutes of actual grinding time, you should ...

  • Allied Telesis 6870 - page 21

    Page 21 of 25 SPEX SamplePrep LLC 9.24.07 Operation : when the 6870 Freezer/Mill is set up for the firs t run of the day, with a loaded vial in the coil, make sure the LN valve on the supply tank or line is open. Go to the STATUS screen and touch RUN. The Auto-Fill valve will open and let LN into the Free zer/Mill tub. The valve may close and open ...

  • Allied Telesis 6870 - page 22

    Page 22 of 25 SPEX SamplePrep LLC 9.24.07 temperature before attempting to clean it. Once the unit has attained room tem perature, wipe down the unit as indicated previously. Af ter every period of use, the m ill is going to be wet with condensation since the Freezer/Mill will pi ck up moisture as long as it is cold. To maintain the exterior of the ...

  • Allied Telesis 6870 - page 23

    Page 23 of 25 SPEX SamplePrep LLC 9.24.07 7.04 Contacting SPEX SamplePrep LLC Within the United States, write, telephone, or e-mail us at: SPEX SamplePrep LLC 15 Liberty St. Metuchen, New Jersey 08840 Tel.: 732-549-7144 or 800-522-7739 Fax: 732-906-2492 Website: www.spexcsp.com E-mail: sampleprep@spexcsp.com Outside the United States, contact the S ...

  • Allied Telesis 6870 - page 24

    Page 24 of 25 SPEX SamplePrep LLC 9.24.07 SECTION 8.0: TROUBLE-SHOOTIN G GUIDE, PAGE 1 OF 2 PROBLEM CAUSE SOLUTION 1 The unit does not turn on No power Ma ke sure power cord is plugged into outlet and inlet 2 The unit does not turn on No power Check outlet for power and correct as required 3 The unit does not turn on Power switch not turned on Swit ...

  • Allied Telesis 6870 - page 25

    Page 25 of 25 SPEX SamplePrep LLC 9.24.07 SECTION 9.0: TROUBLE-SHOOTIN G GUIDE, PAGE 2 OF 2 PROBLEM CAUSE SOLUTION 14 Blunt end-plug doesn’t come off room-temperature vial Hard to grip Warm vial under hot water. Use wide-jaw pliers if necessary. 15 Extractor jams Water on extractor screws or bell Dry extractor before each use 16 Extractor jams Ic ...

Fabbricante Allied Telesis Categoria Freezer

I documenti che otteniamo dal fabbricante del dispositivoAllied Telesis 6870 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Allied Telesis
- manuali per l’uso 6870
- schede prodotto Allied Telesis
- opuscoli
- o etichette energetiche Allied Telesis 6870
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Allied Telesis 6870.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Allied Telesis 6870, manuali di manutenzione, brevi manuali o manuali utente Allied Telesis 6870. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Allied Telesis 6870.

Manuale completo del dispositivo Allied Telesis 6870, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Allied Telesis 6870 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Allied Telesis 6870.

Il manuale per l’uso completo Allied Telesis, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Allied Telesis 6870 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Allied Telesis 6870, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Allied Telesis 6870 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Allied Telesis 6870 - che ci dovrebbe aiutare nei primi passi durante l'uso Allied Telesis 6870
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Allied Telesis 6870
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Allied Telesis 6870 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Allied Telesis 6870?

Utilizza il modulo sottostante

Se non hai risolto il problema con Allied Telesis 6870 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Allied Telesis 6870 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)