Manuale per l’uso Vermont Casting VCPV06

16 pagine 0.36 mb
Scarica

Vai alla pagina of 16

Summary
  • Vermont Casting VCPV06 - page 1

    1 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters Unvented Gas-Fired Room Heater Please read this manual before installing and using appliance. W ARNING: If the information in this manual is not followed exactly , a fire or explosion may result causing property damage, personal injury of loss of life. • Do not store or use gasoline or oth ...

  • Vermont Casting VCPV06 - page 2

    2 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters SAFETY : Accidents are always tragic, especially because so many of them could have been prevented with a little care and judgment. There are some basic good practices we hope you will follow for safe use of your gas fired room heater . IMPORT ANT : Read this user’s manual carefully and co ...

  • Vermont Casting VCPV06 - page 3

    3 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters VCBVMN, VCBVMP , VCPVMN, VCPVMP Specifications Input Rating Regulator Inlet Gas Supply Size Gas (Btu/Hr) V ariable Pressure Pressure of Heater Weight VCBV30MN 15,000 30,000 27” x 24” x 8 ⁵⁄₈ ” 30 lbs. VCBV20MN Natural 10,000 20,000 3.0” w .c. 7.0” w .c. 10.5” w .c. 19 ³⁄ ...

  • Vermont Casting VCPV06 - page 4

    4 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters Installation Installation Requirements Fresh Air for Combustion and V entilation W ARNING: This heater must have fresh air for proper operation. If not, poor fuel combustion could result. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in ...

  • Vermont Casting VCPV06 - page 5

    5 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes. *Aftermarket: Completion of sale, not for purpose of resale from manufacturer . This appliance is only for use with the type of gas indicated on the rating plate. This ...

  • Vermont Casting VCPV06 - page 6

    6 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters 1/16" (1.6mm) RH102 Fig. 4 W all anchor. Connect to Gas Supply Before connecting the appliance, turn off all gas appli- ances. Close the main gas valve at the gas meter or Lp tank. Make certain there is good ventilation where the installation will be made. Installation should comply wit ...

  • Vermont Casting VCPV06 - page 7

    7 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters cleaning. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap prevents moisture and contaminants from going into the heater controls. If the sediment trap is not installed or is installed wrong, the heater may not operate properly . T est for gas leaks with a m ...

  • Vermont Casting VCPV06 - page 8

    8 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters Operating Instructions FOR YOUR SAFETY - READ THIS SECTION BEFORE LIGHTING W ARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTL Y , A FIRE OR EXPLO- SION MA Y RESUL T CAUSING PROPERTY DAM- AGE, PERSONAL INJUR Y OR LOSS OF LIFE. A. BEFORE LIGHTING smell all around the appliance area for g ...

  • Vermont Casting VCPV06 - page 9

    9 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters Pilot and Burner Inspection Each time you light your heater check that the pilot flame and burner flame patterns are as shown in Figures 9, 10 and 1 1. If flame patterns are incorrect, turn the heater off. Contact your dealer or a qualified gas technician for assistance. Do not operate the h ...

  • Vermont Casting VCPV06 - page 10

    10 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters Problem When control knob is pressed in and turned counterclockwise to ignition, there is no spark at ODS pilot. When control knob is pressed in and turned counterclockwise to ignition/pilot position, there is spark but no ignition. ODS pilot lights but flame goes out when control knob is r ...

  • Vermont Casting VCPV06 - page 11

    11 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters T roubleshooting, continued Problem Possible Cause Solution Heater produces a clicking noise just after burner is lit or turned off. Gas odor even when control knob is in OFF position. Gas odor during combustion. Heater shuts off on ODS 1. Metal expanding and contracting. 1. Gas leaks. Refe ...

  • Vermont Casting VCPV06 - page 12

    12 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters 11 13 14 15 10a,b 9 7 8a,b 5 2 3 1 4 16 16 17 19a 21 18 20 22 23 24 19b 12a,b 6a,b The V ermont Castings Majestic Products Company reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. 3769 VCBVMN/MP ...

  • Vermont Casting VCPV06 - page 13

    13 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters 14. T ubing ODS Assembly RBT27XX0 RBT21XX0 RBT15XX0 15. T ubing Inlet Assembly RBT26XX0 RBT20XX0 RBT14XX0 16. Leg - Front RBI06XX0 RBI06XX0 RBI06XX0 17. Front Panel RBP69P A0 RBP66P A0 RBW22XA0 18. Burner Assembly RBW13XX0 RBW09XX0 RBW08XX0 19a. Burner Support - Left RBP06XA RBP06XA- RBP06X ...

  • Vermont Casting VCPV06 - page 14

    14 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters V ermont Castings, Majestic Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. VCPVMN/MP Unvented Room Heater Item / Model Number VCPV06MN/MP VCPV10MN/MP VCPV18MN/MP VCPV30MN/MP 1. Cover H ...

  • Vermont Casting VCPV06 - page 15

    15 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters VCPVMN/MP , continued Item / Model Number VCPV06MN/MP VCPV10MN/MP VCPV18MN/MP VCPV30MN/MP 20. T ubing Outlet - C Assembly -- -- RCT54XX0 RCT12XX0 21. T ubing Outlet - CL Assembly -- -- -- RCT13XX0 22. T ubing Outlet - CR Assembly -- -- RCT14XX0 -- 23. Manifold - “C” -- -- RCD02XX0 -- 24 ...

  • Vermont Casting VCPV06 - page 16

    16 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters © V ermont Castings, Majestic Products W arranty Service and Limited W arranty The V ermont Castings Majestic Products Company warrants this product to be free form defects in materi- als and components for two (2) years from the date of first purchase, provided that the product has been p ...

Fabbricante Vermont Casting Categoria Fan

I documenti che otteniamo dal fabbricante del dispositivoVermont Casting VCPV06 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Vermont Casting
- manuali per l’uso VCPV06
- schede prodotto Vermont Casting
- opuscoli
- o etichette energetiche Vermont Casting VCPV06
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Vermont Casting VCPV06.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Vermont Casting VCPV06, manuali di manutenzione, brevi manuali o manuali utente Vermont Casting VCPV06. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Vermont Casting VCPV06.

Manuali per l’uso simili

Manuale completo del dispositivo Vermont Casting VCPV06, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Vermont Casting VCPV06 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Vermont Casting VCPV06.

Il manuale per l’uso completo Vermont Casting, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Vermont Casting VCPV06 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Vermont Casting VCPV06, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Vermont Casting VCPV06 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Vermont Casting VCPV06 - che ci dovrebbe aiutare nei primi passi durante l'uso Vermont Casting VCPV06
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Vermont Casting VCPV06
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Vermont Casting VCPV06 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Vermont Casting VCPV06?

Utilizza il modulo sottostante

Se non hai risolto il problema con Vermont Casting VCPV06 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Vermont Casting VCPV06 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)