    1 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters Unvented Gas-Fired Room Heater Please read this manual before installing and using appliance. W ARNING: If the information in this manual is not followed exactly , a fire or explosion may result causing property damage, personal injury of loss of life. • Do not store or use gasoline or oth ...

  • Vermont Casting VCPV06 - page 2

    2 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters SAFETY : Accidents are always tragic, especially because so many of them could have been prevented with a little care and judgment. There are some basic good practices we hope you will follow for safe use of your gas fired room heater . IMPORT ANT : Read this user’s manual carefully and co ...

  • Vermont Casting VCPV06 - page 3

    3 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters VCBVMN, VCBVMP , VCPVMN, VCPVMP Specifications Input Rating Regulator Inlet Gas Supply Size Gas (Btu/Hr) V ariable Pressure Pressure of Heater Weight VCBV30MN 15,000 30,000 27” x 24” x 8 ⁵⁄₈ ” 30 lbs. VCBV20MN Natural 10,000 20,000 3.0” w .c. 7.0” w .c. 10.5” w .c. 19 ³⁄ ...

  • Vermont Casting VCPV06 - page 4

    4 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters Installation Installation Requirements Fresh Air for Combustion and V entilation W ARNING: This heater must have fresh air for proper operation. If not, poor fuel combustion could result. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in ...

  • Vermont Casting VCPV06 - page 5

    5 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes. *Aftermarket: Completion of sale, not for purpose of resale from manufacturer . This appliance is only for use with the type of gas indicated on the rating plate. This ...

  • Vermont Casting VCPV06 - page 6

    6 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters 1/16" (1.6mm) RH102 Fig. 4 W all anchor. Connect to Gas Supply Before connecting the appliance, turn off all gas appli- ances. Close the main gas valve at the gas meter or Lp tank. Make certain there is good ventilation where the installation will be made. Installation should comply wit ...

  • Vermont Casting VCPV06 - page 7

    7 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters cleaning. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap prevents moisture and contaminants from going into the heater controls. If the sediment trap is not installed or is installed wrong, the heater may not operate properly . T est for gas leaks with a m ...

  • Vermont Casting VCPV06 - page 8

    8 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters Operating Instructions FOR YOUR SAFETY - READ THIS SECTION BEFORE LIGHTING W ARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTL Y , A FIRE OR EXPLO- SION MA Y RESUL T CAUSING PROPERTY DAM- AGE, PERSONAL INJUR Y OR LOSS OF LIFE. A. BEFORE LIGHTING smell all around the appliance area for g ...

  • Vermont Casting VCPV06 - page 9

    9 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters Pilot and Burner Inspection Each time you light your heater check that the pilot flame and burner flame patterns are as shown in Figures 9, 10 and 1 1. If flame patterns are incorrect, turn the heater off. Contact your dealer or a qualified gas technician for assistance. Do not operate the h ...

  • Vermont Casting VCPV06 - page 10

    10 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters Problem When control knob is pressed in and turned counterclockwise to ignition, there is no spark at ODS pilot. When control knob is pressed in and turned counterclockwise to ignition/pilot position, there is spark but no ignition. ODS pilot lights but flame goes out when control knob is r ...

  • Vermont Casting VCPV06 - page 11

    11 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters T roubleshooting, continued Problem Possible Cause Solution Heater produces a clicking noise just after burner is lit or turned off. Gas odor even when control knob is in OFF position. Gas odor during combustion. Heater shuts off on ODS 1. Metal expanding and contracting. 1. Gas leaks. Refe ...

  • Vermont Casting VCPV06 - page 12

    12 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters 11 13 14 15 10a,b 9 7 8a,b 5 2 3 1 4 16 16 17 19a 21 18 20 22 23 24 19b 12a,b 6a,b The V ermont Castings Majestic Products Company reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. 3769 VCBVMN/MP ...

  • Vermont Casting VCPV06 - page 13

    13 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters 14. T ubing ODS Assembly RBT27XX0 RBT21XX0 RBT15XX0 15. T ubing Inlet Assembly RBT26XX0 RBT20XX0 RBT14XX0 16. Leg - Front RBI06XX0 RBI06XX0 RBI06XX0 17. Front Panel RBP69P A0 RBP66P A0 RBW22XA0 18. Burner Assembly RBW13XX0 RBW09XX0 RBW08XX0 19a. Burner Support - Left RBP06XA RBP06XA- RBP06X ...

  • Vermont Casting VCPV06 - page 14

    14 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters V ermont Castings, Majestic Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. VCPVMN/MP Unvented Room Heater Item / Model Number VCPV06MN/MP VCPV10MN/MP VCPV18MN/MP VCPV30MN/MP 1. Cover H ...

  • Vermont Casting VCPV06 - page 15

    15 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters VCPVMN/MP , continued Item / Model Number VCPV06MN/MP VCPV10MN/MP VCPV18MN/MP VCPV30MN/MP 20. T ubing Outlet - C Assembly -- -- RCT54XX0 RCT12XX0 21. T ubing Outlet - CL Assembly -- -- -- RCT13XX0 22. T ubing Outlet - CR Assembly -- -- RCT14XX0 -- 23. Manifold - “C” -- -- RCD02XX0 -- 24 ...

  • Vermont Casting VCPV06 - page 16

    16 Vermont Castings VCBVMN/MP & VCPVMN/MP Room Heaters © V ermont Castings, Majestic Products W arranty Service and Limited W arranty The V ermont Castings Majestic Products Company warrants this product to be free form defects in materi- als and components for two (2) years from the date of first purchase, provided that the product has been p ...

メーカー Vermont Casting カテゴリー Fan

Vermont Casting VCPV06のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- VCPV06の取扱説明書
- Vermont Castingの製品カード
- パンフレット
- またはVermont Casting VCPV06の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Vermont Casting VCPV06の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Vermont Casting VCPV06の取り付け説明書、サービスマニュアル、簡易説明書、またはVermont Casting VCPV06のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Vermont Casting VCPV06の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Vermont Casting VCPV06デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがVermont Casting VCPV06を使用するのを助ける技術的文書のことです。説明書は通常、全てのVermont Casting VCPV06ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Vermont Castingの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Vermont Casting VCPV06の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははVermont Casting VCPV06の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Vermont Casting VCPV06に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Vermont Casting VCPV06デバイスの基本機能を使うにあたってのヒント。 Vermont Casting VCPV06のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Vermont Casting VCPV06に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるVermont Casting VCPV06のメーカー/サービスへの連絡先に関する情報。

Vermont Casting VCPV06についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもVermont Casting VCPV06の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがVermont Casting VCPV06で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)