    Owner’ s Manual — Phoenix 300 Installation, Operation and Ser vice Instr uctions 1 www .ther mastor .com • sales@thermastor .com T oll-F ree 1-800-533-7533 Read and Sav e These Instr uctions Phoenix 300 High Capacity Dehumidifier P ar t number TS-218 The Phoenix 300 Dehumidifier is designed to maximize the water remo val capacity from a sin ...

  • Therma-Stor Products Group 300 - page 2

    2 www .ther mastor .com • sales@ther mastor .com T oll-F ree 1-800-533-7533 1 Specifications Par t No. 4022599 Pow er 12 amps, 115 V ac, Grounded W ater 176 pints/day @ AHAM 80°F , 60% RH Removal 304 pints/day maximum @ 90°F , 90% RH Blower 540 CFM without external ducting Refrigerant 2 lbs., 5 oz. R-22 Charge Optional Duct 10” round outlet ...

  • Therma-Stor Products Group 300 - page 3

    3 www .ther mastor .com • sales@ther mastor .com T oll-F ree 1-800-533-7533 2.3 Electrical Requirements The Phoenix 300 can be plugged into a grounded 15 Amp circuit. At 80°F , 60% RH, it draws 11.e Amps. Due to the high percentage of a 15 Amp circuit’ s capacity that the unit uses, the circuit should be dedicated to r unning it only . Amp dra ...

  • Therma-Stor Products Group 300 - page 4

    4 www .ther mastor .com • sales@ther mastor .com T oll-F ree 1-800-533-7533 5. Replace the cover . Change the timer pegs back to the original pattern for use above 50°F . 2.11 Low Pressure Control If the low side refrigerant pressure drops to 15 PSIG, the low pressure control opens and shuts off the compressor and blower . It is an automatically ...

  • Therma-Stor Products Group 300 - page 5

    5 www .ther mastor .com • sales@ther mastor .com T oll-F ree 1-800-533-7533 coil where it absorbs heat from the incoming air and evaporates. The evaporator operates in a flooded condition, which means that all the evaporator tubes contain liquid refrigerant during normal operation. A flooded evaporator should maintain constant pressure and temp ...

  • Therma-Stor Products Group 300 - page 6

    6 www .ther mastor .com • sales@ther mastor .com T oll-F ree 1-800-533-7533 Evaporator coil frosted continuously , low dehumidifying capacity . 1. Defrost thermostat loose or defective (Sec. 2.10 and 4.7). 2. Defrost timer incorrectly set or defective (Sec. 2.10 and 4.7). 2. Low refrigerant charge (Sec. 4.4). 3. Dir ty air filter or air flow re ...

  • Therma-Stor Products Group 300 - page 7

    7 www .ther mastor .com • sales@ther mastor .com T oll-F ree 1-800-533-7533 and water . These contaminants must be carefully removed otherwise even small residues will attack replacement compressor motors and cause failures. The following procedure is effective only if the system is monitored after replacing the compressor to insure that the clea ...

  • Therma-Stor Products Group 300 - page 8

    8 www .ther mastor .com • sales@ther mastor .com T oll-F ree 1-800-533-7533 Figure 3: Electrical schematic of Phoenix 300 5 Wiring Diagram 4.9 Rela y The contacts of the single pole, single throw relay complete the power circuit to the compressor . The contacts are closed when power is pro vided to the relay coil via the control circuit. The cont ...

  • Therma-Stor Products Group 300 - page 9

    9 www .ther mastor .com • sales@ther mastor .com T oll-F ree 1-800-533-7533 Item Par t No. Qty . Description 1 4021818 1 Accumulator 2 4022636 1 Air Filter , Pleated, 2” x 20” x 20” 4022614 1 Air Filter , Pleated, 4” x 20” x 20” MERV-8 4022624 1 Air Filter , Pleated, 4” x 20” x 20” (90-95% EFFICIENT) 3 4021083 1 Blow er w/ Capac ...

  • Therma-Stor Products Group 300 - page 10

    10 www .ther mastor .com • sales@ther mastor .com T oll-F ree 1-800-533-7533 This page intentionally left blank. ...

  • Therma-Stor Products Group 300 - page 11

    11 www .ther mastor .com • sales@ther mastor .com T oll-Free 1-800-533-7533 Phoenix 300 Dehumidifier Limited W ar ranty W ar rantor : Therma-Stor LLC PO Box 8680 Madison, WI 53708 T elephone: 1-800-533-7533 Who Is Covered: This w arranty extends only to the original end-user of the Phoenix 300 dehumidifier , and ma y not be assigned or transfer ...

Fabbricante Therma-Stor Products Group Categoria Dehumidifier

I documenti che otteniamo dal fabbricante del dispositivoTherma-Stor Products Group 300 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Therma-Stor Products Group
- manuali per l’uso 300
- schede prodotto Therma-Stor Products Group
- opuscoli
- o etichette energetiche Therma-Stor Products Group 300
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Therma-Stor Products Group 300.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Therma-Stor Products Group 300, manuali di manutenzione, brevi manuali o manuali utente Therma-Stor Products Group 300. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Therma-Stor Products Group 300.

Manuale completo del dispositivo Therma-Stor Products Group 300, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Therma-Stor Products Group 300 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Therma-Stor Products Group 300.

Il manuale per l’uso completo Therma-Stor Products Group, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Therma-Stor Products Group 300 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Therma-Stor Products Group 300, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Therma-Stor Products Group 300 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Therma-Stor Products Group 300 - che ci dovrebbe aiutare nei primi passi durante l'uso Therma-Stor Products Group 300
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Therma-Stor Products Group 300
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Therma-Stor Products Group 300 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Therma-Stor Products Group 300?

Utilizza il modulo sottostante

Se non hai risolto il problema con Therma-Stor Products Group 300 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Therma-Stor Products Group 300 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)