    Owner’ s Manual — Phoenix 300 Installation, Operation and Ser vice Instr uctions 1 www .ther mastor .com • sales@thermastor .com T oll-F ree 1-800-533-7533 Read and Sav e These Instr uctions Phoenix 300 High Capacity Dehumidifier P ar t number TS-218 The Phoenix 300 Dehumidifier is designed to maximize the water remo val capacity from a sin ...

  • Therma-Stor Products Group 300 - page 2

    2 www .ther mastor .com • sales@ther mastor .com T oll-F ree 1-800-533-7533 1 Specifications Par t No. 4022599 Pow er 12 amps, 115 V ac, Grounded W ater 176 pints/day @ AHAM 80°F , 60% RH Removal 304 pints/day maximum @ 90°F , 90% RH Blower 540 CFM without external ducting Refrigerant 2 lbs., 5 oz. R-22 Charge Optional Duct 10” round outlet ...

  • Therma-Stor Products Group 300 - page 3

    3 www .ther mastor .com • sales@ther mastor .com T oll-F ree 1-800-533-7533 2.3 Electrical Requirements The Phoenix 300 can be plugged into a grounded 15 Amp circuit. At 80°F , 60% RH, it draws 11.e Amps. Due to the high percentage of a 15 Amp circuit’ s capacity that the unit uses, the circuit should be dedicated to r unning it only . Amp dra ...

  • Therma-Stor Products Group 300 - page 4

    4 www .ther mastor .com • sales@ther mastor .com T oll-F ree 1-800-533-7533 5. Replace the cover . Change the timer pegs back to the original pattern for use above 50°F . 2.11 Low Pressure Control If the low side refrigerant pressure drops to 15 PSIG, the low pressure control opens and shuts off the compressor and blower . It is an automatically ...

  • Therma-Stor Products Group 300 - page 5

    5 www .ther mastor .com • sales@ther mastor .com T oll-F ree 1-800-533-7533 coil where it absorbs heat from the incoming air and evaporates. The evaporator operates in a flooded condition, which means that all the evaporator tubes contain liquid refrigerant during normal operation. A flooded evaporator should maintain constant pressure and temp ...

  • Therma-Stor Products Group 300 - page 6

    6 www .ther mastor .com • sales@ther mastor .com T oll-F ree 1-800-533-7533 Evaporator coil frosted continuously , low dehumidifying capacity . 1. Defrost thermostat loose or defective (Sec. 2.10 and 4.7). 2. Defrost timer incorrectly set or defective (Sec. 2.10 and 4.7). 2. Low refrigerant charge (Sec. 4.4). 3. Dir ty air filter or air flow re ...

  • Therma-Stor Products Group 300 - page 7

    7 www .ther mastor .com • sales@ther mastor .com T oll-F ree 1-800-533-7533 and water . These contaminants must be carefully removed otherwise even small residues will attack replacement compressor motors and cause failures. The following procedure is effective only if the system is monitored after replacing the compressor to insure that the clea ...

  • Therma-Stor Products Group 300 - page 8

    8 www .ther mastor .com • sales@ther mastor .com T oll-F ree 1-800-533-7533 Figure 3: Electrical schematic of Phoenix 300 5 Wiring Diagram 4.9 Rela y The contacts of the single pole, single throw relay complete the power circuit to the compressor . The contacts are closed when power is pro vided to the relay coil via the control circuit. The cont ...

  • Therma-Stor Products Group 300 - page 9

    9 www .ther mastor .com • sales@ther mastor .com T oll-F ree 1-800-533-7533 Item Par t No. Qty . Description 1 4021818 1 Accumulator 2 4022636 1 Air Filter , Pleated, 2” x 20” x 20” 4022614 1 Air Filter , Pleated, 4” x 20” x 20” MERV-8 4022624 1 Air Filter , Pleated, 4” x 20” x 20” (90-95% EFFICIENT) 3 4021083 1 Blow er w/ Capac ...

  • Therma-Stor Products Group 300 - page 10

    10 www .ther mastor .com • sales@ther mastor .com T oll-F ree 1-800-533-7533 This page intentionally left blank. ...

  • Therma-Stor Products Group 300 - page 11

    11 www .ther mastor .com • sales@ther mastor .com T oll-Free 1-800-533-7533 Phoenix 300 Dehumidifier Limited W ar ranty W ar rantor : Therma-Stor LLC PO Box 8680 Madison, WI 53708 T elephone: 1-800-533-7533 Who Is Covered: This w arranty extends only to the original end-user of the Phoenix 300 dehumidifier , and ma y not be assigned or transfer ...

Manufacturer Therma-Stor Products Group Category Dehumidifier

Documents that we receive from a manufacturer of a Therma-Stor Products Group 300 can be divided into several groups. They are, among others:
- Therma-Stor Products Group technical drawings
- 300 manuals
- Therma-Stor Products Group product data sheets
- information booklets
- or energy labels Therma-Stor Products Group 300
All of them are important, but the most important information from the point of view of use of the device are in the user manual Therma-Stor Products Group 300.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Therma-Stor Products Group 300, service manual, brief instructions and user manuals Therma-Stor Products Group 300. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Therma-Stor Products Group 300.

A complete manual for the device Therma-Stor Products Group 300, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Therma-Stor Products Group 300 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Therma-Stor Products Group 300.

A complete Therma-Stor Products Group manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Therma-Stor Products Group 300 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Therma-Stor Products Group 300, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Therma-Stor Products Group 300, that we can find in the current document
3. Tips how to use the basic functions of the device Therma-Stor Products Group 300 - which should help us in our first steps of using Therma-Stor Products Group 300
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Therma-Stor Products Group 300
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Therma-Stor Products Group 300 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Therma-Stor Products Group 300?

Use the form below

If you did not solve your problem by using a manual Therma-Stor Products Group 300, ask a question using the form below. If a user had a similar problem with Therma-Stor Products Group 300 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)