    Sierra Series 730 Accu-Mass ™ Mass Flow Meters Instruction Manual Part Number IM-73-AM Revision E 0 5 /0 4 5 Harris Court, Building L Monterey, CA 93940 (831) 373-0200 (800) 866-0200 Fax (831) 373-4402 http://www.sierrainstruments.com Sierra Instruments b.v. Bolstoen 30A 1046 AV Amsterdam The Netherlands +31(0)20-6145810 Fax +31(0)20-6145815 ...

  • Sierra 730 - page 2

    Customer Notice Sierra Instruments, Inc. is not liable for any damage or personal injury, whatsoever, resulting from the use of Sierra Instruments standard mass flow meters for oxygen gas. You are responsible for determining if this mass flow meter is appropriate for your oxygen application. You are responsible for cleaning the mass flow meter to t ...

  • Sierra 730 - page 3

    Series 730 Instruction Manual IM-73- E 1 Table of Contents Series 730 Mass Flow Meters...........................................................3 Safety Information..........................................................................4 Receipt of Components...................................................................4 Technical Assistanc ...

  • Sierra 730 - page 4

    Series 730 Instruction Manual 2 IM-73- E Warnings and Cautions Warning! All wiring procedures must be performed with the power Off. Caution! All flow meter connections and fittings must have the same or higher pres- sure rating as the main pipeline. Caution! Do not connect power to the 4-20 mA terminals. Caution! Before attempting any flow meter re ...

  • Sierra 730 - page 5

    Series 730 Instruction Manual IM-73- E 3 Series 730 Mass Flow Meters Sierra’s Series 730 Accu-Mass ™ Flow Meters provide outstanding measurement accuracy and fast 200 millisecond response time. The meters monitor the mass flow rate of air and process gases in ranges from 0 to 250 scfm. They are available in pipe sizes from 1/4-inch to 3 inches. ...

  • Sierra 730 - page 6

    Series 730 Instruction Manual 4 IM-73- E Safety Information We use caution and warning statements in this book to draw your at- tention to important information. Warning! Caution! This statement appears with information that is important to protect people and equipment from damage. Pay very close attention to all warn- ings that apply to your appli ...

  • Sierra 730 - page 7

    Series 730 Instruction Manual IM-73- E 5 Installation Overview When selecting an installation site, make sure that: 1. Line pressure and temperature will not exceed the flow meter rating. Temperature should not vary more than 120°F (50°C) from the calibration temperature. Line pressure should not vary more than 50 psi (3.4 bar) around the calibra ...

  • Sierra 730 - page 8

    Series 730 Instruction Manual 6 IM-73- E Flow meter 10 D 5 D One 90° elbow before meter Flow meter 15 D 5 D Two 90° elbows before meter in one plane Flow meter 25 D 10 D Two 90° elbows before meter out of plane (if three 90° bends present, double recommended length) Flow meter 10 D 5 D Reduction before meter Flow meter 20 D 5 D Expansion before ...

  • Sierra 730 - page 9

    Series 730 Instruction Manual IM-73-D 7 Wiring Connections - NEMA 2 CE Enclosures NEMA 2 enclosures are supplied with a 6 -pin connector for direct connection to the supplied mating connector. The pin designations are given in Figure 3 below. Connect 15 VDC input power (300 mA load, maximum) to pin 1 and power ground to pin 5 . See “Output Sig- n ...

  • Sierra 730 - page 10

    Series 730 Instruction Manual 8 IM-73- E Output Signal Wiring All flow meters are equipped with either a calibrated 0–5 VDC, 0–10 VDC or 4–20 mA output signal. These linear output signals represent 0 to 100% of the flow meter user full scale. DC Output Wiring The 0-5 VDC or 0-10 VDC output signal can drive a minimum load of 1000 Ohms. For 0-5 ...

  • Sierra 730 - page 11

    Series 730 Instruction Manual IM-73- E 9 Problem Possible Cause Solution Flow measurement is erratic or fluctuating Very erratic or non-uniform flow Follow installation requirements shown in Figure 2 Flow meter installed with less than re- quired minimum pipe diameters up- stream and downstream of the sensor Follow installation requirements shown i ...

  • Sierra 730 - page 12

    Series 730 Instruction Manual 10 IM-73- E Returning Equipment to Factory Before returning any mass flow meter to the factory, you must com- plete a Sierra Calibration/Repair Data Sheet. You may download the data sheet to your computer by visiting the Sierra website at www.sierrainstruments.com. Or, contact Customer Service at: service@sierrainstrum ...

  • Sierra 730 - page 13

    Series 730 Instruction Manual IM-73- E 11 Product Specifications Operating Specifications Gases Most non-combustible, non-corrosive gases Mass Flow Rates Mass Flow Rate for Air (1) NPT Size Minimum Range Maximum Range 1/4-inch 0–0.035 scfm 0–4.5 scfm 1/2-inch 0–0.5 scfm 0–12 scfm 3/4-inch 0–1 scfm 0–25 scfm 1 1/4-inch 0–2 scfm 0–50 ...

  • Sierra 730 - page 14

    No#. Color Signal 1 Black Sig. Ground 2 White Signal 3 Red DC input P ower 4 N/C 5 N/C 6 Green P ower Ground 7 (Brown or Orange) (Bridge) 730/600 WIRING C ONNECTIONS Blue Hi Rose Connector F emale Mating Connector Solder Side No#. Color Signal 1 Black Sig. Ground 2 White Signal 3 Red DC input P ower 4 N/C 5 N/C 6 Green Po wer Ground 7 (Brown or Ora ...

Fabbricante Sierra Categoria Automobile Parts

I documenti che otteniamo dal fabbricante del dispositivoSierra 730 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Sierra
- manuali per l’uso 730
- schede prodotto Sierra
- opuscoli
- o etichette energetiche Sierra 730
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Sierra 730.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Sierra 730, manuali di manutenzione, brevi manuali o manuali utente Sierra 730. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Sierra 730.

Manuali per l’uso simili

Manuale completo del dispositivo Sierra 730, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Sierra 730 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Sierra 730.

Il manuale per l’uso completo Sierra, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Sierra 730 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Sierra 730, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Sierra 730 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Sierra 730 - che ci dovrebbe aiutare nei primi passi durante l'uso Sierra 730
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Sierra 730
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Sierra 730 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Sierra 730?

Utilizza il modulo sottostante

Se non hai risolto il problema con Sierra 730 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Sierra 730 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)