  • Sierra 730 - page 1

    Sierra Series 730 Accu-Mass ™ Mass Flow Meters Instruction Manual Part Number IM-73-AM Revision E 0 5 /0 4 5 Harris Court, Building L Monterey, CA 93940 (831) 373-0200 (800) 866-0200 Fax (831) 373-4402 http://www.sierrainstruments.com Sierra Instruments b.v. Bolstoen 30A 1046 AV Amsterdam The Netherlands +31(0)20-6145810 Fax +31(0)20-6145815 ...

  • Sierra 730 - page 2

    Customer Notice Sierra Instruments, Inc. is not liable for any damage or personal injury, whatsoever, resulting from the use of Sierra Instruments standard mass flow meters for oxygen gas. You are responsible for determining if this mass flow meter is appropriate for your oxygen application. You are responsible for cleaning the mass flow meter to t ...

  • Sierra 730 - page 3

    Series 730 Instruction Manual IM-73- E 1 Table of Contents Series 730 Mass Flow Meters...........................................................3 Safety Information..........................................................................4 Receipt of Components...................................................................4 Technical Assistanc ...

  • Sierra 730 - page 4

    Series 730 Instruction Manual 2 IM-73- E Warnings and Cautions Warning! All wiring procedures must be performed with the power Off. Caution! All flow meter connections and fittings must have the same or higher pres- sure rating as the main pipeline. Caution! Do not connect power to the 4-20 mA terminals. Caution! Before attempting any flow meter re ...

  • Sierra 730 - page 5

    Series 730 Instruction Manual IM-73- E 3 Series 730 Mass Flow Meters Sierra’s Series 730 Accu-Mass ™ Flow Meters provide outstanding measurement accuracy and fast 200 millisecond response time. The meters monitor the mass flow rate of air and process gases in ranges from 0 to 250 scfm. They are available in pipe sizes from 1/4-inch to 3 inches. ...

  • Sierra 730 - page 6

    Series 730 Instruction Manual 4 IM-73- E Safety Information We use caution and warning statements in this book to draw your at- tention to important information. Warning! Caution! This statement appears with information that is important to protect people and equipment from damage. Pay very close attention to all warn- ings that apply to your appli ...

  • Sierra 730 - page 7

    Series 730 Instruction Manual IM-73- E 5 Installation Overview When selecting an installation site, make sure that: 1. Line pressure and temperature will not exceed the flow meter rating. Temperature should not vary more than 120°F (50°C) from the calibration temperature. Line pressure should not vary more than 50 psi (3.4 bar) around the calibra ...

  • Sierra 730 - page 8

    Series 730 Instruction Manual 6 IM-73- E Flow meter 10 D 5 D One 90° elbow before meter Flow meter 15 D 5 D Two 90° elbows before meter in one plane Flow meter 25 D 10 D Two 90° elbows before meter out of plane (if three 90° bends present, double recommended length) Flow meter 10 D 5 D Reduction before meter Flow meter 20 D 5 D Expansion before ...

  • Sierra 730 - page 9

    Series 730 Instruction Manual IM-73-D 7 Wiring Connections - NEMA 2 CE Enclosures NEMA 2 enclosures are supplied with a 6 -pin connector for direct connection to the supplied mating connector. The pin designations are given in Figure 3 below. Connect 15 VDC input power (300 mA load, maximum) to pin 1 and power ground to pin 5 . See “Output Sig- n ...

  • Sierra 730 - page 10

    Series 730 Instruction Manual 8 IM-73- E Output Signal Wiring All flow meters are equipped with either a calibrated 0–5 VDC, 0–10 VDC or 4–20 mA output signal. These linear output signals represent 0 to 100% of the flow meter user full scale. DC Output Wiring The 0-5 VDC or 0-10 VDC output signal can drive a minimum load of 1000 Ohms. For 0-5 ...

  • Sierra 730 - page 11

    Series 730 Instruction Manual IM-73- E 9 Problem Possible Cause Solution Flow measurement is erratic or fluctuating Very erratic or non-uniform flow Follow installation requirements shown in Figure 2 Flow meter installed with less than re- quired minimum pipe diameters up- stream and downstream of the sensor Follow installation requirements shown i ...

  • Sierra 730 - page 12

    Series 730 Instruction Manual 10 IM-73- E Returning Equipment to Factory Before returning any mass flow meter to the factory, you must com- plete a Sierra Calibration/Repair Data Sheet. You may download the data sheet to your computer by visiting the Sierra website at www.sierrainstruments.com. Or, contact Customer Service at: service@sierrainstrum ...

  • Sierra 730 - page 13

    Series 730 Instruction Manual IM-73- E 11 Product Specifications Operating Specifications Gases Most non-combustible, non-corrosive gases Mass Flow Rates Mass Flow Rate for Air (1) NPT Size Minimum Range Maximum Range 1/4-inch 0–0.035 scfm 0–4.5 scfm 1/2-inch 0–0.5 scfm 0–12 scfm 3/4-inch 0–1 scfm 0–25 scfm 1 1/4-inch 0–2 scfm 0–50 ...

  • Sierra 730 - page 14

    No#. Color Signal 1 Black Sig. Ground 2 White Signal 3 Red DC input P ower 4 N/C 5 N/C 6 Green P ower Ground 7 (Brown or Orange) (Bridge) 730/600 WIRING C ONNECTIONS Blue Hi Rose Connector F emale Mating Connector Solder Side No#. Color Signal 1 Black Sig. Ground 2 White Signal 3 Red DC input P ower 4 N/C 5 N/C 6 Green Po wer Ground 7 (Brown or Ora ...

Manufacturer Sierra Category Automobile Parts

Documents that we receive from a manufacturer of a Sierra 730 can be divided into several groups. They are, among others:
- Sierra technical drawings
- 730 manuals
- Sierra product data sheets
- information booklets
- or energy labels Sierra 730
All of them are important, but the most important information from the point of view of use of the device are in the user manual Sierra 730.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Sierra 730, service manual, brief instructions and user manuals Sierra 730. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Sierra 730.

Similar manuals

A complete manual for the device Sierra 730, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Sierra 730 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Sierra 730.

A complete Sierra manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Sierra 730 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Sierra 730, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Sierra 730, that we can find in the current document
3. Tips how to use the basic functions of the device Sierra 730 - which should help us in our first steps of using Sierra 730
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Sierra 730
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Sierra 730 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Sierra 730?

Use the form below

If you did not solve your problem by using a manual Sierra 730, ask a question using the form below. If a user had a similar problem with Sierra 730 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)