  • First Alert FA148CP - page 1

       3URJUDPPLQJ*XLGH ON OFF AR M E D R E A D Y A B C D 6 4 7 9 # 3 5 8 0 2 1 FA260 R A R M E D R E A D Y FA560 6 4 7 9 # 3 5 8 0 2 1 R AWAY STA Y P A G E K5305-5PRV2 10/03 Rev. A ) $  & 36   ) $  & 3   6 6 H H F F X X U U L L W W   6 6 V V W W H H P P V V  ...

  • First Alert FA148CP - page 2

    – 2 – TO ENTER PROGRAMMING MODE: Local programming requires the use of an alpha keypad connected to the keypad term inals on the control. A. PO WER UP, then depress [ ✱ ] and [#] both at once, within 50 seconds of powering up (if ✱ 98 was used to exit program mode, this method m ust be used to reenter program mode). OR B. Initially, key: In ...

  • First Alert FA148CP - page 3

    – 3 – 352*5$00,1*)250  Entries apply to both the FA168CPS and FA148CP controls, except entries shown in dashed boxes, which apply only to the FA168CPS (partition entries) and are not applicable to the FA148CP . Entry of a number other than one specified will give unpredictable results. Values shown in brackets are factory defaults. Fie ...

  • First Alert FA148CP - page 4

    – 4 – NOTE: Entry of a number other than one specifie d will give unpredic table re sults. For fields *43 thr u *46: Enter 0 – 9; #+11 for B; #+12 for C; #+13 for D; #+14 for E; #+15 for F. Enter [ ✱ ] as the fourth digit i f a 3-digit account number (for 3+1 dialer reporting format) is used. Enter 0 as the first digi t of a 4-digit account ...

  • First Alert FA148CP - page 5

    – 5 – ✱ 65 OPEN REPORT CODE [0,0,0] S ee box above. Part. 1 Part. 2 Common ✱ 66 ARM AWAY/STAY RPT CODE [0,0,0 ,0,0,0] See box above. Away Stay Away Stay Away Stay Part. 1 Part. 2 Common ✱ 67 RF XMTR LOW BAT REPORT CODE | [00] See box on previ ous page. UL: must be enabled if wi reless dev ices are used ✱ 68 CANCEL REPORT CODE | [00] See ...

  • First Alert FA148CP - page 6

    – 6 – ✱ 92 PHONE LINE MONITOR ENABLE UL: see Inst. Instru ctions for req uireme nts [0,0] 1 2 NOTE: Output Device must either be programmed to be STOPPED in fie ld ✱ 80 or STOPPED by Code + # + 8 + output number. Entry 1: : 0 = dis abled, 1-15 = 1 mi n - 15 min (#+10 = 10 min; #+11 = 11 mi n; #+12 = 12 min; #+13 = 13 min; #+14 = 14 min; #+1 ...

  • First Alert FA148CP - page 7

    – 7 – MISCELLANEOUS SYSTEM FIELDS (*174-*181) ✱ 174 CLEAN ME REPORTING OPTIONS (for ESL s moke det ectors ) [0] 0 = disabl e; 1 = Clean Me s ignal reports ; Note: If Clean M e is enabled, you must enter “ 3 ” in field ✱ 56 program ming for z one 1 response t ime. ✱ 177 DEVICE DURATION 1, 2 (used in *80 Menu mode-Dev ice A ctions 5/6) ...

  • First Alert FA148CP - page 8

    – 8 – Configurable Zone Types Worksheets Configurable zone types 90 and 91 can be programmed v ia downloader software or from a keypad us ing data fields*182-*185. Configurable z one types 92 and 93 (F A168CPS only) c an only be programmed us ing the downloader software. Programming Configurable Zone T ype options inv olves mak ing 10 entries i ...

  • First Alert FA148CP - page 9

    – 9 – *56 ZONE PROGRAMMING WORKSHEET (FA148CP supports up to 32 zones: 1-6, 9-34, 49-56) [default shown in brackets] Zone Zn Type Part. Report Hardw ire Type Rsp. Tim e Location 1 [09] [1] [EOL] [1] 2 [01] [1] [EOL] [1] 3 [03] [1] [EOL] [1] 4 [03] [1] [EOL] [1] 5 [03] [1] [EOL] [1] 6 [03] [1] [EOL] [1] 7 [03] [1] [EOL] [1] 8 [03] [1] [EOL] [1] ...

  • First Alert FA148CP - page 10

    – 10 – *57 FUNCTION KEY PROGRAMMING Option Function A B C D Comments 01 Paging 02 Time Disp lay 03 Arm AWAY 04 Arm STAY 05 Arm NIGHT-STAY 06 Step Armi ng 07 Device Activation Device: 08 Comm. Test 09 Macro Key 1 10 Macro Key 2 11 Macro Key 3 12 Macro Key 4 00 Emer gen cy Keys: zone 95 zone 99 zone 96 paging Personal Emergency n/a Silent Alarm n ...

  • First Alert FA148CP - page 11

    – 11 – ✱ 80 OUTPUT DEFINITIONS Fill in the required data on the worksheet below and follow the programming procedure in the installation m anual as you enter the data during the displays and prompts that appear in sequence. Notes: 1. For Relays, 4229 and 4204 devices are programmed in * 79, *80, and *81 modes. 2. For Powerline Carrier devices ...

  • First Alert FA148CP - page 12

    – 12 – Zone Type Definitions Type 00 Zone Not Used Use this zone ty pe if the z one is not used. Type 01 Entry/Exit Burglary #1 • Assi gn to zones that are us ed for primary entry and ex it. • Provides entry delay if the c ontrol is armed in t he Away or St ay modes . • No entry delay is prov ided when the panel is armed in the I nstant m ...

  • First Alert FA148CP - page 13

    – 13 – Type 21 Arm-Away • Arms th e system in Aw ay mode w hen the zone is ac tivat ed. • Pushbutton unit s send t he user number t o the cent ral stat ion when arming or dis arming. • User code for butt on must be assigned. Type 22 Disarm • Di sarms th e system w hen the zone is acti vated. • User code for butt on must be assigned. T ...

  • First Alert FA148CP - page 14

    – 14 – ALPHA VOCABULARY LIST (For Entering Zone Descriptors) 000 (Word Space) – A – • 001 AIR • 002 ALARM ∗ 004 A LLEY 005 AMBUSH • 006 AREA • 007 APARTM ENT • 009 ATTIC ∗ 010 A UDIO – B – • 012 BABY ∗ • 013 BACK ∗ • 014 BAR • 016 BASEMENT ∗ • 017 BATHROOM ∗ • 018 BED • 019 BEDROOM ∗ 020 B ELL • 0 ...

  • First Alert FA148CP - page 15

    – 15 – 5800 Series Transmitter Input Loop Identification All of the transmitters illustrated below have one or more unique factory assigned input (loop) ID codes. Each of the inputs requires its own programming zone (e.g., a 5804's four inputs require four programming zones). WIRELESS INPUT TYPES "RF" (Supervised RF) Type send pe ...

  • First Alert FA148CP - page 16

    CLASS 2 PLUG-IN TRANSFORMER 16.5V AC, 25V A (e.g. 1321). (USE No. 1321CN IN CANADA) TO 110V AC UNSWITCHED OUTLET (24HR) THIS EQUIPMENT SHOULD BE INST ALLED IN ACCORD ANCE WITH THE NA TIONAL FIRE PROTECTION ASSOCIA TION'S ST ANDARD 72, CHAPTER 2 (NA TIONAL FIRE PROTECTION ASSOCIA TION, BA TTERY - MARCH P ARK, QUINCY ,MA 02269). PRINTED INFORMA ...

Fabbricante First Alert Categoria Home Security System

I documenti che otteniamo dal fabbricante del dispositivoFirst Alert FA148CP possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici First Alert
- manuali per l’uso FA148CP
- schede prodotto First Alert
- opuscoli
- o etichette energetiche First Alert FA148CP
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso First Alert FA148CP.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione First Alert FA148CP, manuali di manutenzione, brevi manuali o manuali utente First Alert FA148CP. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto First Alert FA148CP.

Manuali per l’uso simili

Manuale completo del dispositivo First Alert FA148CP, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare First Alert FA148CP dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti First Alert FA148CP.

Il manuale per l’uso completo First Alert, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale First Alert FA148CP - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice First Alert FA148CP, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per First Alert FA148CP che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo First Alert FA148CP - che ci dovrebbe aiutare nei primi passi durante l'uso First Alert FA148CP
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del First Alert FA148CP
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio First Alert FA148CP in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su First Alert FA148CP?

Utilizza il modulo sottostante

Se non hai risolto il problema con First Alert FA148CP con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con First Alert FA148CP è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)