Manuale per l’uso Bunn 40410.0000G

20 pagine 5.21 mb
Scarica

Vai alla pagina of 20

Summary
  • Bunn 40410.0000G - page 1

    Smar t W ave Series Smar t W ave Silver Series Series ® INST ALLA TION & OPERA TING GUIDE BUNN-O-MA TIC CORPORA TION POST OFFICE BO X 3227 SPRINGFIELD , ILLINOIS 62708-3227 PHONE: (217) 529-6601 F AX: (217) 529-6644 T o ensure you have the latest revision of the Operating Manual, or to view the Illustrated Parts Catalog, Programming Manual, or ...

  • Bunn 40410.0000G - page 2

    Page 2 40410 030912 BUNN-O-MA TIC COMMERCIAL PRODUCT WARRANTY Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) Airpots, thermal carafes, decanters, GPR servers, iced tea/coffee dispensers, MCP/MCA pod brewers thermal ser vers and Thermofresh servers (mechanical and digital)- 1 year parts and 1 year labor . 2) All ...

  • Bunn 40410.0000G - page 3

    Page 3 CONTENTS Warranty .............................................................................................................2 Introduction ........................................................................................................3 User Notices .................................................................................. ...

  • Bunn 40410.0000G - page 4

    Page 4 ELECTRICAL REQUIREMENTS CAUTION - The brewer must be disconnected from the power source until specified in Initial Set-Up. Refer to Data Plate on the Brewer , and local/national electrical codes to determine circuit requirements. Electrical Hook-Up CAUTION – Improper electrical installation will damage electronic components. 1. An electri ...

  • Bunn 40410.0000G - page 5

    Page 5 PLUMBING REQUIREMENTS These brewers must be connected to a cold water system with operating pressure between 20 and 90 psi (138 and 620 kPa) from a 1 ⁄ 2 " or larger supply line. A shut-off valve should be installed in the line before the brewer . Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce ...

  • Bunn 40410.0000G - page 6

    Page 6 INITIAL SET UP CAUTION - The brewer must be disconnected from the power source throughout the initial set-up, except when specified in the instructions. 1. Insert an empty funnel into the funnel rails. (FIG 4) 2. Place an empty server under the funnel. For taller ser vers, lift up on the front of the booster plate, and slide it back into th ...

  • Bunn 40410.0000G - page 7

    Page 7 COFFEE BREWING 1. Begin each brew cycle with a clean empty brew funnel. 2. Insert a BUNN filter into the funnel. (FIG 6) 3. Pour (or grind) fresh coffee into the filter and level the bed of grounds by gently shaking. 4. Slide the funnel into the funnel rails until it stops. 5. Place an empty server under the funnel. 6. Verify that the &quo ...

  • Bunn 40410.0000G - page 8

    Page 8 OPERA TING CONTROLS - SIL VER SERIES (A) ENABLE BREW ON/OFF SWITCH Pressing the "ENABLE BREW ON/OFF" switch (indicator on) enables the brew circuit, and energizes the tank refill circuit. Pressing the switch again (indicator off) stops tank refilling and brewing. Stopping a brew cycle after it has been started will not stop the ? ...

  • Bunn 40410.0000G - page 9

    Page 9 40410 092407 PROGRAMMING - SIL VER SERIES BREW VOLUME SET -UP: NOTE: Set small and large batches separately . Maximum water on time is 5 minutes. Use the following steps when the setting is unknown. 1. Place an empty funnel in the funnel rails and an empty server beneath the funnel. 2. Press the "ENABLE BREW ON/OFF" switch ("O ...

  • Bunn 40410.0000G - page 10

    Page 10 B C A (A) ENABLE BREW ON/OFF SWITCH Pressing the "ENABLE BREW ON/OFF" switch (indicator/display on) enables the brew circuit, and the tank refill circuit. Pressing the switch again (indicator/display off) stops tank refilling and brewing. Stopping a brew cycle after it has been started will not stop the flow of water into the s ...

  • Bunn 40410.0000G - page 11

    Page 11 40410 092211 PROGRAMMING - SMAR T W A VE WITH DISPLA Y BREW VOLUME SET -UP: NOTE: Maximum water on time is 5 minutes. 1. Press the "HIDDEN" switch until display reads A1. This represents the adjust mode "Brew Time" for the "A" brew switch. The display will then change to (minutes-seconds). Press "BREW A&qu ...

  • Bunn 40410.0000G - page 12

    Page 12 Remove sprayhead by turning counterclockwise DELIMING Bunn-O-Matic recommends deliming your coffee brewer periodically . The actual frequency of deliming de- pends on the mineral content of the water you use. NOTE: In hard water areas, this may need to be done daily . It will help prevent liming problems in the brewer and takes less than a ...

  • Bunn 40410.0000G - page 13

    Page 13 FIG 12 FIG 11 CLEANING The use of a damp cloth rinsed in any mild, non-abrasive, liquid detergent is recommended for cleaning all surfaces on Bunn-O-Matic equipment. CLEANING OPTIONAL LARGE SPRA YHEAD 1. Remove the brew funnel. 2. Remove the sprayhead by turning it counterclockwise with your fingertips. 3. Disassemble sprayhead by removing ...

  • Bunn 40410.0000G - page 14

    Page 14 CO VER REMO V AL Unplug the brewer and let it cool down before proceeding. Front Wrap: 1. Remove the brew funnel. 2. Remove upper and lower screws on either side of front cover . 3. Loosen middle screw on either side of front cover . 4. Pull front cover towards front of brewer . T op Cover: 1. Remove both screws. 2. Lift top cover to clear ...

  • Bunn 40410.0000G - page 15

    Page 15 DRAINING T ANK 1. Unplug the brewer and let it cool down before proceeding. 2. Remove the brew funnel. 3. Remove the front cover . 4. Pinch fill hose. 5. Loosen clamp from fill solenoid.. 6. Remove hose from solenoid and drain into sink as shown (or 2 gallon bucket). 7. After draining, reinstall hose and clamp. (Hand tighten only) . FIG 1 ...

  • Bunn 40410.0000G - page 16

    Page 16 1 2 3 4 OFF ON FIG 16 SWITCH SETTINGS Program Switches: 1. Unplug the brewer and let it cool down before proceeding. 3. Remove the left rear cover . 4. Flip the dip switches as needed. NOTE: All switches are turned OFF from factory . FIG 15 KEY # FUNCTION - OFF FUNCTION - ON 4. High altitude Set temp 200°F (93°C) Set temp 190°F (87.8°C) ...

  • Bunn 40410.0000G - page 17

    Page 17 TR OUBLESHOO TING 40410 092407 RED LED FLASHES DISPLA Y DESCRIPTION ACTION 1. ER 1 TEMP SENSOR SHORTED CALL SERVICE 2. ER 2 TEMP SENSOR OPEN CALL SERVICE 3. ER 3 HEA TING TOO LONG CALL SERVICE 4. ER 4 REFILL TOO LONG CHECK WA TER SUPPL Y 5. ER 5 HIGH T ANK LEVEL-DURING BREW DELIME 6. ER 6 CHECK "ENABLE BREW ON/OFF" SWITCH CHECK SW ...

  • Bunn 40410.0000G - page 18

    Page 18 - SCHEMA TIC WIRING DIAGRAM W A VE 15 APS, 15 S APS 40405.0001A 02/08 ©2008 BUNN-O-MA TIC CORPORA TION T ANK HEA TER LIMIT THERMOST A T VENT V AL VE SOLENOID 12VDC L1 NT BLU/BLK BLK-14 230V AC 2 WIRE + GND SINGLE PHASE RED/BLK WHI WHI BLU BRN J2-1 J5-1 BRN - ON/0 OFF ORN +12 ORN GRN TA N WHI/ORN +12 WHI PNK RED/BLK - ON/0 OFF GRN YEL WHI/R ...

  • Bunn 40410.0000G - page 19

    Page 19 SCHEMA TIC WIRING DIAGRAM W A VE 120/240V APS SERIES 40405.0002A 02/08 ©2008 BUNN-O-MA TIC CORPORA TION 120/240V AC 3 WIRE + GND SINGLE PHASE Chassis Ground Earth Ground GRN/YEL - T ANK HEA TER LIMIT THERMOST A T VENT V AL VE SOLENOID 12VDC L1 NT BLK BLK-14 RED/BLK RED WHI WHI BLK J2-1 J5-1 BRN - ON/0 OFF ORN +12 ORN GRN TA N WHI/ORN +12 W ...

  • Bunn 40410.0000G - page 20

    Page 20 - SCHEMA TIC WIRING DIAGRAM WA VE 15 APS, 15 S APS 40405.0003A 04/10 ©2010 BUNN-O-MA TIC CORPORATION T ANK HEATER LIMIT THERMOS TAT VENT VA LVE SOLENOID 12VDC L1 NT C O N T R O L P C B O A R D BLK BLK-14 100/120V AC 2 WIRE + GND SINGLE PHASE RED/BLK WHI WHI WHI BLK J2-1 J5-1 BRN - ON/0 OFF ORN +12 ORN GRN TA N WHI/ORN +12 BLK PNK RED/BLK - ...

Fabbricante Bunn Categoria Coffeemaker

I documenti che otteniamo dal fabbricante del dispositivoBunn 40410.0000G possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Bunn
- manuali per l’uso 40410.0000G
- schede prodotto Bunn
- opuscoli
- o etichette energetiche Bunn 40410.0000G
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Bunn 40410.0000G.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Bunn 40410.0000G, manuali di manutenzione, brevi manuali o manuali utente Bunn 40410.0000G. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Bunn 40410.0000G.

Manuali per l’uso simili

Manuale completo del dispositivo Bunn 40410.0000G, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Bunn 40410.0000G dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Bunn 40410.0000G.

Il manuale per l’uso completo Bunn, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Bunn 40410.0000G - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Bunn 40410.0000G, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Bunn 40410.0000G che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Bunn 40410.0000G - che ci dovrebbe aiutare nei primi passi durante l'uso Bunn 40410.0000G
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Bunn 40410.0000G
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Bunn 40410.0000G in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Bunn 40410.0000G?

Utilizza il modulo sottostante

Se non hai risolto il problema con Bunn 40410.0000G con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Bunn 40410.0000G è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)