  • Chicago Electric 67119 - page 1

    1-1/2 HP PLUNGE ROUTER 671 19 SET UP AND OPERA TING INSTRUCTIONS Distributed exclusively by Harbor Freight T ools ® . 3491 Mission Oaks Blvd., Camarillo, CA 9301 1 Visit our website at: http://www .harborfreight.com Read this material before using this product. Failure to do so can result in serious injury . SA VE THIS MANUAL. Copyright © 2009 by ...

  • Chicago Electric 67119 - page 2

    SKU 671 19 For technical questions, please call 1-800-444-3353. Page 2 CONTENTS IMPORT ANT SAFETY INFORMA TION ............................ 3 GENERAL POWER T OOL SAFETY W ARNINGS....................... 3 PLUNGE ROUTER SAFETY W ARNINGS ...................................... 5 VIBRA TION SAFETY ......................... 7 GROUNDING .................. ...

  • Chicago Electric 67119 - page 3

    SKU 671 19 For technical questions, please call 1-800-444-3353. Page 3 SA VE THIS MANUAL Keep this manual for the safety warn- ings and precautions, assembly , operat- ing, inspection, maintenance and cleaning procedures. Write the product’ s serial number in the back of the manual near the assembly diagram (or month and year of purchase if produ ...

  • Chicago Electric 67119 - page 4

    SKU 671 19 For technical questions, please call 1-800-444-3353. Page 4 Unmodied plugs and matching out - lets will reduce risk of electric shock. A void body contact with grounded b. surfaces such as pipes, radiators, ranges and refrigerators. There is an increased risk of electric shock if your body is grounded. Do not expose power tools to rai ...

  • Chicago Electric 67119 - page 5

    SKU 671 19 For technical questions, please call 1-800-444-3353. Page 5 Power tool use and care 4. Do not force the power tool. Use a. the correct power tool for your application. The correct power tool will do the job better and safer at the rate for which it was designed. Do not use the power tool if the b. switch does not turn it on and off. Any ...

  • Chicago Electric 67119 - page 6

    SKU 671 19 For technical questions, please call 1-800-444-3353. Page 6 Keep hands away from the cutting 8. area. Do not place hands beneath the workpiece for any reason. Keep the base of the router in rm contact with the workpiece while cutting. Keep Handles dry , clean, and free of 9. oil or grease. This will permit better control of the tool. ...

  • Chicago Electric 67119 - page 7

    SKU 671 19 For technical questions, please call 1-800-444-3353. Page 7 • Do not use with power switch locked on. • Properly maintain and inspect to avoid electrical shock. • Any power cord must be properly grounded. Ground Fault Circuit Inter- rupter (GFCI) should also be imple- mented – it prevents sustained elec- trical shock. W ARNING: S ...

  • Chicago Electric 67119 - page 8

    SKU 671 19 For technical questions, please call 1-800-444-3353. Page 8 Grip tool as lightly as possible (while 6. still keeping safe control of it). Let the tool do the work. T o reduce vibration, maintain the tool 7. as explained in this manual. If any abnormal vibration occurs, stop use immediately . SA VE THESE INSTRUCTIONS. GROUNDING TO PREVENT ...

  • Chicago Electric 67119 - page 9

    SKU 671 19 For technical questions, please call 1-800-444-3353. Page 9 Double Insulated T ools: T ools with T wo Prong Plugs Outlets for 2-Prong Plug T ools marked “Double Insulated” do 1. not require grounding. They have a special double insulation system which satises OSHA requirements and complies with the applicable standards of Underwri ...

  • Chicago Electric 67119 - page 10

    SKU 671 19 For technical questions, please call 1-800-444-3353. Page 10 RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS* (120/240 VOL T) NAMEPLA TE AMPERES (at full load) EXTENSION CORD LENGTH 25’ 50’ 75’ 100’ 150’ 0 – 2.0 18 18 18 18 16 2.1 – 3.4 18 18 18 16 14 3.5 – 5.0 18 18 16 14 12 5.1 – 7.0 18 16 14 12 12 7.1 – 12.0 18 ...

  • Chicago Electric 67119 - page 11

    SKU 671 19 For technical questions, please call 1-800-444-3353. Page 1 1 SPECIFICA TIONS Power 1-1/2 HP Electrical Input 120 V~ / 60 Hz / 10 A Motor Speed 1 1,000 - 28,000 RPM (No Load) Collet Capacity 1/4” Maximum Plunge 2-1/8” Depth Measurements 1/16” increments Depth Stop 4-stage turret stop E194601 93MA UNP ACKING When unpacking, make sur ...

  • Chicago Electric 67119 - page 12

    SKU 671 19 For technical questions, please call 1-800-444-3353. Page 12 OPERA TING INSTRUCTIONS Read the ENTIRE IMPORT ANT SAFETY INFORMA TION section at the beginning of this manual including all text under subheadings therein before set up or use of this product. T ool Set Up TO PREVENT SERIOUS INJUR Y FROM ACCIDENT AL OPERA TION: T urn the Power ...

  • Chicago Electric 67119 - page 13

    SKU 671 19 For technical questions, please call 1-800-444-3353. Page 13 Loosen the Thumb Screw so that the 1. Depth Stop Bar (30) can slide freely . Rotate the Adjusting Knob (26) until 2. the Depth Adjusting Bolt (29) pro - trudes about 1/4” from the Depth Stop Bar . Rotate the Depth Stop Bar to the left 3. so that the indexing mark along the to ...

  • Chicago Electric 67119 - page 14

    SKU 671 19 For technical questions, please call 1-800-444-3353. Page 14 Slide the bars on the Edge Guide b. into the slots on the Base of the Router with the fence facing the workpiece. Note: The Edge Guide can be inserted into either side of the tool to make cuts along the left or right side of the material. Adjust the distance between the c. rout ...

  • Chicago Electric 67119 - page 15

    SKU 671 19 For technical questions, please call 1-800-444-3353. Page 15 tool may try to twist from the strong initial torque. Note: The Router bit should always be fed into the stock from left to right so as to match the clockwise rotation of the router . When cutting outside edges, rotate the router counterclockwise. Rotate it clockwise when cutti ...

  • Chicago Electric 67119 - page 16

    SKU 671 19 For technical questions, please call 1-800-444-3353. Page 16 MAINTENANCE AND SER VICING Procedures not specically explained in this manual must be performed only by a qualied technician. TO PREVENT SERIOUS INJUR Y FROM ACCIDENT AL OPERA TION: T urn the Power Switch of the tool off and unplug the tool from its electrical outlet befo ...

  • Chicago Electric 67119 - page 17

    SKU 671 19 For technical questions, please call 1-800-444-3353. Page 17 T roubleshooting Problem Possible Causes Likely Solutions T ool will not start. Cord not connected. 1. No power at outlet. 2. T ool’ s thermal reset breaker 3. tripped (if equipped). Internal damage or wear . 4. (Carbon brushes or switch, for example.) Check that cord is plug ...

  • Chicago Electric 67119 - page 18

    SKU 671 19 For technical questions, please call 1-800-444-3353. Page 18 Part Description Qty 1 T apping Screw 8 2 Cover 1 3 Screw 2 4 Speed Adjuster 1 5 T apping Screw 5 6 T apping Screw 2 7 Cover 1 8 Cover 1 9 T apping Screw 2 10 Epoxy Board 2 11 Brush Holder 2 12 Carbon Brush 2 13 Motor Housing 1 14 Spring 1 15 W asher 1 16 Bearing 1 17 Stator 1 ...

  • Chicago Electric 67119 - page 19

    SKU 671 19 For technical questions, please call 1-800-444-3353. Page 19 ASSEMBL Y DIAGRAM Record Product’ s Serial Number Here: Note: If product has no serial number , record month and year of purchase instead. Note: Some parts are listed and shown for illustration purposes only , and are not avail- able individually as replacement parts. 85 ...

  • Chicago Electric 67119 - page 20

    SKU 671 19 For technical questions, please call 1-800-444-3353. Page 20 LIMITED 90 DA Y W ARRANTY Harbor Freight T ools Co. makes every ef fort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this prod- uct is free from defects in materials and workmanship for the period of 90 days ...

Fabbricante Chicago Electric Categoria Router

I documenti che otteniamo dal fabbricante del dispositivoChicago Electric 67119 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Chicago Electric
- manuali per l’uso 67119
- schede prodotto Chicago Electric
- opuscoli
- o etichette energetiche Chicago Electric 67119
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Chicago Electric 67119.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Chicago Electric 67119, manuali di manutenzione, brevi manuali o manuali utente Chicago Electric 67119. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Chicago Electric 67119.

Manuali per l’uso simili

Manuale completo del dispositivo Chicago Electric 67119, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Chicago Electric 67119 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Chicago Electric 67119.

Il manuale per l’uso completo Chicago Electric, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Chicago Electric 67119 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Chicago Electric 67119, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Chicago Electric 67119 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Chicago Electric 67119 - che ci dovrebbe aiutare nei primi passi durante l'uso Chicago Electric 67119
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Chicago Electric 67119
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Chicago Electric 67119 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Chicago Electric 67119?

Utilizza il modulo sottostante

Se non hai risolto il problema con Chicago Electric 67119 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Chicago Electric 67119 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)