    © Copyright 2000 Nortel Networks. This document may be freely reproduced and distributed whole and intact including this Copyright Notice. Contivity™ Extranet Switch 4500 FIPS 140-1 Non-Proprietary Cryptographic Module Security Policy Level 2 Validation February 2000 ...

  • Nortel 4500 FIPS - page 2

    © Copyright 2000 Nortel Networks. 2 Table of Contents 1 Introduction .................................................................................................................. 3 1.1 Purpose ................................................................................................................... 3 1.2 References .................. ...

  • Nortel 4500 FIPS - page 3

    © Copyright 2000 Nortel Networks. 3 1 Introduction 1.1 Purpose This is a non-proprietary Cryptographic Module Security Policy for the Contivity™ Extranet Switch 4500. This security policy describes how the Contivity™ Extranet Switch 4500 meets the security requirements of FIPS 140-1, and how to operate the Contivity™ Extranet Switch 4500 in ...

  • Nortel 4500 FIPS - page 4

    © Copyright 2000 Nortel Networks. 4 This document provides an overview of the Contivity™ Switch and explains the secure configuration and operation of the module. This introduction section is followed by Section 2, which details the general features and functionality of the Contivity™ Switch. Section 3 specifically addresses the required confi ...

  • Nortel 4500 FIPS - page 5

    © Copyright 2000 Nortel Networks. 5 2 The Contivity Extranet 4500 Switch The Nortel Networks Contivity Extranet Switch 4500 provides a scalable, secure, manageable remote access server that meets FIPS 140-1 level 2 requirements. This section will describe the general features and functionality provided by the Contivity Extranet Switch. Section 3 w ...

  • Nortel 4500 FIPS - page 6

    © Copyright 2000 Nortel Networks. 6 . Figure 2 – Physical Interfaces The physical interfaces include the dual power plugs for the redundant power supplies, the power and reset buttons, the serial port, the LAN Port RJ-45 connector, and up to six slots containing additional network connectors. The power and reset buttons light up to indicate powe ...

  • Nortel 4500 FIPS - page 7

    © Copyright 2000 Nortel Networks. 7 Figure 4 – 10/100BASE-TX LAN LEDs These physical interfaces are separated into the logical interfaces from FIPS as described in the following table: Switch physical interface FIPS 140-1 Logical Interface 10/100BASE-TX LAN Port, LAN Port, Serial Port Data Input Interface 10/100BASE-TX LAN Port, LAN Port, Serial ...

  • Nortel 4500 FIPS - page 8

    © Copyright 2000 Nortel Networks. 8 front bezel allows access to the dual power supplies, hard drives, and floppy drive. Removing the top cover or the I/O panel allows access to the motherboard, memory, and expansion slots. Figure 5 – The Steel Cover of the Extranet Switch 4500 Once the Extranet Switch 4500 has been configured in its FIPS 140-1 ...

  • Nortel 4500 FIPS - page 9

    © Copyright 2000 Nortel Networks. 9 (2) Top Cover Labels (2) Front Bezel Labels Figure 6 – Tamper-Evident Labels Applied to Switch Front Bezel and Top Cover (2) AC Filter Input Labels (1) Air Hole Label (1) I/O Panel Label (1) Keyboard Connector Label Figure 7 – Tamper Evident Labels Applied to Rear Panel The tamper-evident seals are produced ...

  • Nortel 4500 FIPS - page 10

    © Copyright 2000 Nortel Networks. 10 Attempting to remove a label breaks it or continually tears off small fragments as depicted in Figure 9 . Other signs of tamper-evidence include a strong smell of organic solvents, warped or bent cover metal, and scratches in the paint on the module. FIPS 140-1 Level 2 Tamper Evident Label Serial Number: 567342 ...

  • Nortel 4500 FIPS - page 11

    © Copyright 2000 Nortel Networks. 11 • IPSec Protocol Tunnels • PPTP Protocol Tunnels • L2TP Protocol Tunnels • L2F Protocol Tunnels • Change Password 2.4.1 Crypto Officer Services There is a factory default login ID and password, which allows access to the Crypto Officer role. This initial account is the primary administrator's acc ...

  • Nortel 4500 FIPS - page 12

    © Copyright 2000 Nortel Networks. 12 • Status Functions : to view the switch configuration, routing tables, active sessions, use Gets to view SNMP { XE "SNMP" } MIB II { XE "SNMP:MIB II" } statistics, usage graphs, health, temperature, memory status, voltage, packet statistics, and review accounting logs. • Manage the Switc ...

  • Nortel 4500 FIPS - page 13

    © Copyright 2000 Nortel Networks. 13 2.5 Key Management The switch securely administers both cryptographic keys and other critical security parameters such as User passwords. Ephemeral sessions keys are created during the negotiation of secure tunnels on behalf of Users who have successfully authenticated themselves to the switch with their user I ...

  • Nortel 4500 FIPS - page 14

    © Copyright 2000 Nortel Networks. 14 Recommended • Change the default administrator password on the switch. • Disable all management protocols over private non- tunnelled interfaces Required • Select the “FIPS Enabled” button on the Service Available Management screens and restart the module. • Apply the tamper evident labels as descri ...

Fabbricante Nortel Categoria Switch

I documenti che otteniamo dal fabbricante del dispositivoNortel 4500 FIPS possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Nortel
- manuali per l’uso 4500 FIPS
- schede prodotto Nortel
- opuscoli
- o etichette energetiche Nortel 4500 FIPS
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Nortel 4500 FIPS.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Nortel 4500 FIPS, manuali di manutenzione, brevi manuali o manuali utente Nortel 4500 FIPS. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Nortel 4500 FIPS.

Manuali per l’uso simili

Manuale completo del dispositivo Nortel 4500 FIPS, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Nortel 4500 FIPS dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Nortel 4500 FIPS.

Il manuale per l’uso completo Nortel, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Nortel 4500 FIPS - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Nortel 4500 FIPS, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Nortel 4500 FIPS che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Nortel 4500 FIPS - che ci dovrebbe aiutare nei primi passi durante l'uso Nortel 4500 FIPS
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Nortel 4500 FIPS
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Nortel 4500 FIPS in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Nortel 4500 FIPS?

Utilizza il modulo sottostante

Se non hai risolto il problema con Nortel 4500 FIPS con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Nortel 4500 FIPS è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)