Manuale per l’uso Bryant FH4B

12 pagine 0.25 mb
Scarica

Vai alla pagina of 12

Summary
  • Bryant FH4B - page 1

    Form No. PDS FH4B.01.3 FAN UNIT FH4B Sizes 001 thru 004 PRA CTICALITY & PERFORMANCE Reliability , dependability , and great v alue are built into the FH4B F an Units. The unit is compact and easy to install, with capacities ranging from 800 to 2000 CFM. The units are the r ight choice if you need v ersatility and affordability in a f an unit. T ...

  • Bryant FH4B - page 2

    —2— M A N U F A C T U R E R C E R T I F I E D T O A R I A S C O M P L Y I N G W I T H A R I S T A N D A R D 2 1 0 U N I T A R Y A I R C O N D I T I O N I N G E Q U I P M E N T M A N U F A C T U R E R C E R T I F I E D T O A R I A S C O M P L Y I N G W I T H A R I S T A N D A R D 2 4 0 U N I T A R Y H E A T P U M P E Q U I P M E N T ® FEATURES ...

  • Bryant FH4B - page 3

    — 3 — DIMENSIONS UNIT SERIES ABC F A CCY . COIL CONFIGURA TION OPERA TING WEIGHT (Lb) In. In. In. In. SLOPE “A” FH4BNF001 E 42-11/16 14-5/16 12-7/16 12-5/16 ✓ 1 75 FH4BNF002 E 49-5/8 17-5/8 15-3/4 15-5/8 ✓ 1 92 FH4BNF003 E 49-5/8 21-1/8 19-1/4 19-1/8 ✓ 106 FH4BNF004 E 53-7/16 21-1/8 19-1/4 19-1/8 ✓ 114.5 A02300 ...

  • Bryant FH4B - page 4

    — 4 — DIMENSIONS Continued A02301 ...

  • Bryant FH4B - page 5

    — 5 — A02294 DIMENSIONS Continued *Side Return not compatible when used in conjunction with accessor y cooling coil Field-modified Side Return Location For Slope Coils Only POWER ENTRY OPTIONS LOW VOLT ENTRY OPTIONS FIELD MODIFIED SIDE RETURN LOCATION FOR SLOPE COIL UNITS ONLY FIELD SUPPLIED RETURN PLENUM UNIT FH4B001 FH4B002 A 12 In. 17 In. A ...

  • Bryant FH4B - page 6

    — 6 — SPECIFICA TIONS AIRFLO W PERFORMANCE* (CFM) * With factory approv ed fi lter , 10-kw elec heat 001 and 002 sizes, 15-kw elec heat 003 and 004 sizes 230-v olt. AIRFLO W PERFORMANCE WITH A CCESSOR Y COIL (CFM) NO TES: 1. Air fl ow based upon dry coil at 230v with factory approved accessory fi lter and electric heater (10-kw electr ic hea ...

  • Bryant FH4B - page 7

    — 7 — F AN COIL ELECTRICAL DA T A (UNITS WITHOUT ELECTRICAL HEAT) * Use copper wire only . 75 ° C must be used in this application. When using non-metallic (NM) sheathed cable, wire siz e required should be based on that of 60 ° C conductors, instead of wire sizes sho wn in table abo ve per NEC 1999 Article 336-26. FLA — Full Load Amps NO T ...

  • Bryant FH4B - page 8

    — 8 — SMART HEA T * Field conv er tible to 1 phase . † KF AEH2501N09 is fi eld conv er tible to 3 phase . ‡ Single point wiring kit required for these heaters in Canada. ** Blo wer motor heat not included. When using units with 20-, 24-, and 30-kw electric heaters, maintain a 1-in. clearance from combustib le materials to discharge plenum ...

  • Bryant FH4B - page 9

    — 9 — ELECTRIC HEATER ELECTRICAL DATA SMART HEA T ELECTRICAL D A T A FIELD MULTIPOINT WIRING OF 24-AND 30-KW SINGLE PHASE † Field conv ertible to 1 phase, single or multiple supply circuit. ‡ Field conv ertible to 3 phase. ** Includes blo wer motor amps of largest f an coil used with heater . †† Copper wire must be used. If other than u ...

  • Bryant FH4B - page 10

    — 10 — ELECTRIC HEA TER ST A TIC PRESSURE DROP The air fl ow perf or mance data was de veloped using f an coils with 10-kw electr ic heaters (2 elements) in the 001 and 002 size units and 15-kw heaters (3 elements) in the 003 and 004 size units . 001, 002 003, 004 The air fl ow perf ormance data was dev eloped using fan coils with 10-kw elect ...

  • Bryant FH4B - page 11

    — 11 — ELECTRONIC AIR CLEANER VENTILA TOR PLUS ZONE PERFECT PLUS EQUIPMENT CONTR OLLER ™ HEA T PUMP HUMIDIFIER F AN COIL A02295 MATCHED SYSTEM ...

  • Bryant FH4B - page 12

    — 12 — SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS Cancels: PDS FH4B.01.2 Form PDS FH4B.01.3 © 2003 Bryant Heating & Cooling Systems, 7310 W. Morris St. Indpls, IN 46231 PRINTED IN U.S.A. Catalog No. 12FH -4B2 9-03 SERVICE TRAINING Packaged Service Training programs ar ...

Fabbricante Bryant Categoria Fan

I documenti che otteniamo dal fabbricante del dispositivoBryant FH4B possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Bryant
- manuali per l’uso FH4B
- schede prodotto Bryant
- opuscoli
- o etichette energetiche Bryant FH4B
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Bryant FH4B.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Bryant FH4B, manuali di manutenzione, brevi manuali o manuali utente Bryant FH4B. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Bryant FH4B.

Manuali per l’uso simili

Manuale completo del dispositivo Bryant FH4B, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Bryant FH4B dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Bryant FH4B.

Il manuale per l’uso completo Bryant, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Bryant FH4B - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Bryant FH4B, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Bryant FH4B che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Bryant FH4B - che ci dovrebbe aiutare nei primi passi durante l'uso Bryant FH4B
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Bryant FH4B
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Bryant FH4B in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Bryant FH4B?

Utilizza il modulo sottostante

Se non hai risolto il problema con Bryant FH4B con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Bryant FH4B è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)