    Form No. PDS FH4B.01.3 FAN UNIT FH4B Sizes 001 thru 004 PRA CTICALITY & PERFORMANCE Reliability , dependability , and great v alue are built into the FH4B F an Units. The unit is compact and easy to install, with capacities ranging from 800 to 2000 CFM. The units are the r ight choice if you need v ersatility and affordability in a f an unit. T ...

  • Bryant FH4B - page 2

    —2— M A N U F A C T U R E R C E R T I F I E D T O A R I A S C O M P L Y I N G W I T H A R I S T A N D A R D 2 1 0 U N I T A R Y A I R C O N D I T I O N I N G E Q U I P M E N T M A N U F A C T U R E R C E R T I F I E D T O A R I A S C O M P L Y I N G W I T H A R I S T A N D A R D 2 4 0 U N I T A R Y H E A T P U M P E Q U I P M E N T ® FEATURES ...

  • Bryant FH4B - page 3

    — 3 — DIMENSIONS UNIT SERIES ABC F A CCY . COIL CONFIGURA TION OPERA TING WEIGHT (Lb) In. In. In. In. SLOPE “A” FH4BNF001 E 42-11/16 14-5/16 12-7/16 12-5/16 ✓ 1 75 FH4BNF002 E 49-5/8 17-5/8 15-3/4 15-5/8 ✓ 1 92 FH4BNF003 E 49-5/8 21-1/8 19-1/4 19-1/8 ✓ 106 FH4BNF004 E 53-7/16 21-1/8 19-1/4 19-1/8 ✓ 114.5 A02300 ...

  • Bryant FH4B - page 4

    — 4 — DIMENSIONS Continued A02301 ...

  • Bryant FH4B - page 5

    — 5 — A02294 DIMENSIONS Continued *Side Return not compatible when used in conjunction with accessor y cooling coil Field-modified Side Return Location For Slope Coils Only POWER ENTRY OPTIONS LOW VOLT ENTRY OPTIONS FIELD MODIFIED SIDE RETURN LOCATION FOR SLOPE COIL UNITS ONLY FIELD SUPPLIED RETURN PLENUM UNIT FH4B001 FH4B002 A 12 In. 17 In. A ...

  • Bryant FH4B - page 6

    — 6 — SPECIFICA TIONS AIRFLO W PERFORMANCE* (CFM) * With factory approv ed fi lter , 10-kw elec heat 001 and 002 sizes, 15-kw elec heat 003 and 004 sizes 230-v olt. AIRFLO W PERFORMANCE WITH A CCESSOR Y COIL (CFM) NO TES: 1. Air fl ow based upon dry coil at 230v with factory approved accessory fi lter and electric heater (10-kw electr ic hea ...

  • Bryant FH4B - page 7

    — 7 — F AN COIL ELECTRICAL DA T A (UNITS WITHOUT ELECTRICAL HEAT) * Use copper wire only . 75 ° C must be used in this application. When using non-metallic (NM) sheathed cable, wire siz e required should be based on that of 60 ° C conductors, instead of wire sizes sho wn in table abo ve per NEC 1999 Article 336-26. FLA — Full Load Amps NO T ...

  • Bryant FH4B - page 8

    — 8 — SMART HEA T * Field conv er tible to 1 phase . † KF AEH2501N09 is fi eld conv er tible to 3 phase . ‡ Single point wiring kit required for these heaters in Canada. ** Blo wer motor heat not included. When using units with 20-, 24-, and 30-kw electric heaters, maintain a 1-in. clearance from combustib le materials to discharge plenum ...

  • Bryant FH4B - page 9

    — 9 — ELECTRIC HEATER ELECTRICAL DATA SMART HEA T ELECTRICAL D A T A FIELD MULTIPOINT WIRING OF 24-AND 30-KW SINGLE PHASE † Field conv ertible to 1 phase, single or multiple supply circuit. ‡ Field conv ertible to 3 phase. ** Includes blo wer motor amps of largest f an coil used with heater . †† Copper wire must be used. If other than u ...

  • Bryant FH4B - page 10

    — 10 — ELECTRIC HEA TER ST A TIC PRESSURE DROP The air fl ow perf or mance data was de veloped using f an coils with 10-kw electr ic heaters (2 elements) in the 001 and 002 size units and 15-kw heaters (3 elements) in the 003 and 004 size units . 001, 002 003, 004 The air fl ow perf ormance data was dev eloped using fan coils with 10-kw elect ...

  • Bryant FH4B - page 11

    — 11 — ELECTRONIC AIR CLEANER VENTILA TOR PLUS ZONE PERFECT PLUS EQUIPMENT CONTR OLLER ™ HEA T PUMP HUMIDIFIER F AN COIL A02295 MATCHED SYSTEM ...

  • Bryant FH4B - page 12

    — 12 — SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS Cancels: PDS FH4B.01.2 Form PDS FH4B.01.3 © 2003 Bryant Heating & Cooling Systems, 7310 W. Morris St. Indpls, IN 46231 PRINTED IN U.S.A. Catalog No. 12FH -4B2 9-03 SERVICE TRAINING Packaged Service Training programs ar ...

メーカー Bryant カテゴリー Fan

Bryant FH4Bのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- FH4Bの取扱説明書
- Bryantの製品カード
- パンフレット
- またはBryant FH4Bの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Bryant FH4Bの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Bryant FH4Bの取り付け説明書、サービスマニュアル、簡易説明書、またはBryant FH4Bのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Bryant FH4Bの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Bryant FH4Bデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBryant FH4Bを使用するのを助ける技術的文書のことです。説明書は通常、全てのBryant FH4Bユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Bryantの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Bryant FH4Bの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBryant FH4Bの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Bryant FH4Bに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Bryant FH4Bデバイスの基本機能を使うにあたってのヒント。 Bryant FH4Bのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Bryant FH4Bに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBryant FH4Bのメーカー/サービスへの連絡先に関する情報。

Bryant FH4Bについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBryant FH4Bの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBryant FH4Bで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)