    Operation Husky™ 2200 Air -Operated Diaphragm Pum p 3A2578B EN Polypropylene and PVDF pumps for fluid transfer applications, including high viscosity materials. For professional use only. Not for use in European explosive atmosphere locations. Importan t Safety Instru ctions Read all warni ngs and inst ruction s in this manu al and in your Repai ...

  • Graco 3A2578B - page 2

    Contents Wa rni ng s ........................................................... 3 Or der in g In fo rm ati on ........................................... 6 Related Manu a ls ................................................ 6 Co nfig ura ti on N umb er Ma tri x ............................... 7 In st al la ti on.................................... ...

  • Graco 3A2578B - page 3

    Warnings Warnings The following warnings are for th e setup, use, gro unding, mai ntenance, and repai r of thi s equipment . The exclamation p oint symbol alert s you to a general warni ng and the hazard symbols refer t o p rocedure- specific risks. When th ese symbols appear in th e body of thi s manual or on warni ng labels, refe r bac kt ot h e ...

  • Graco 3A2578B - page 4

    Warnings WARNING EQUIPMENT MISUSE HAZARD Misuse can cau se death or ser ious injury. • Do not oper ate the unit when fatigu ed or under the influence of dr ugs or alco hol. • Do not exce ed the maximum working pressur e or tempera ture rating o f the lowest r ated system compo nent. See Technical Data in all equipment manuals. • Use fluids ...

  • Graco 3A2578B - page 5

    Warnings WARNING TOXIC FLUID OR FUMES HAZARD Toxic fluids or fumes can cause s erious injury o r death if splashed in th e eyes or on skin, inhaled, or s wallowed. • Read MSDSs to know the specific hazards of th e fluids you are using. • Route exhaus t away f rom work area. If diaphragm ruptures, fluid may be exhausted in to the air. • St ...

  • Graco 3A2578B - page 6

    Ordering Inform ation Ordering Info rmation To Find Your Ne arest Distributor 1. Visit www.graco.c om . 2. Click on Where to Buy and use the Distributor Locator. To Specify the Configuration of a New Pump Please call your distributor. OR Use the On line Husky Se lector Tool on the Process Equipmen t page at www.graco.com . To Order Replacement Par ...

  • Graco 3A2578B - page 7

    Con fi guration Nu mber Matrix Configuration Number Matrix Check the identi fication plat e (ID) for th e Configuration Nu mber of your pum p. Use the following ma trix to define the compone nts of your pump. CONFIGURA TION NO. P ART NO. SERIAL NO. SERIES DA TE CODE MAX WPR PSI-bar Graco Inc., P .O. Box 1441 Mpls, MN 55440 USA MADE IN Sample C ...

  • Graco 3A2578B - page 8

    Installation Installation General Information The Typical Inst allation shown is only a gui de for selecting and in stalling system com ponents. Contac t your Graco distr ibutor for assistance in pla nning a system to suit your n eeds. Always use Genuine Graco Parts and accessories. Be sure all accessories are adequatel y sized and pressur e rated ...

  • Graco 3A2578B - page 9

    Installation Accessories/Components Not Supp lied System Components A Air supply lin e J Air inle t port (not vi sible) B Bleed-type maste r air valve (may be required for you r pump) K Air exhaust port and muf fler C Air filter/re gulator assembly L Fluid inlet port D Master air valve (to isolate th e filter/regul ator for service) M Fluid outl ...

  • Graco 3A2578B - page 10

    Installation Ground The Sys tem The equipmen t must be grounded t o reduce the risk of stati c sparking. Static sparking can cause fumes t o igni te or explode. Grounding provid es an escape wire f or the electrical current. • Always ground the entir e fluid system as described belo w. • Polypropyle ne and PVDF pumps are not conductive and are ...

  • Graco 3A2578B - page 11

    Installation Air Exhaust Ventilation If pumping tox ic fluids, you must vent the exhaust away from peo ple, ani mals, foo d handling a reas, and all sourc es of ignition. Follow all applica ble codes. NOTICE The air ex haust port is 1 in . npt(f). Do not r estrict the air exhaust port. Excessive exhaust restriction can cause errati c pump operati ...

  • Graco 3A2578B - page 12

    Installation Fluid Supply L ine 1. Use grounded, flexible fluid ho ses (E). See Ground The System, pag e 10 . 2. If the inl et fluid pressure to the pump i s more than 25% of t he outlet w orking pressu re, the ball check valves will not cl ose fast enough, resulting in i nefficient pump oper ation. Excessive inlet fluid pressure also will sho ...

  • Graco 3A2578B - page 13

    Installation Flange Connec tions The fluid inlet and ou tlet ports are 2 i n. (50 mm) raised face, ANSI /DIN PN 10 flanges. Connect 2 in. (50 mm) plast ic pipe flange t o the pump as fol lows. You will need: • Torqu e wrenc h • Adjustable w rench • 6 in. (152 mm ) diameter, 1/8 in ( 32 mm) thick PTFE gasket ,w i t hf o u r0 . 7 5i n( 1 9m ...

  • Graco 3A2578B - page 14

    Operation Operation Pressure Reli ef Procedure Follow the Pressure Relief Procedure whenever you see this symbol . This equipment stays pressuri zed until pressure is relieved manu ally. To help prevent serious injury from pressurized fl uid, such as s plashing in the eyes or on skin, fo llow the Pressure Relief Procedure when you stop pump ing an ...

  • Graco 3A2578B - page 15

    Maintenance Maintenance Maintenance Schedule Establish a p reventive maintenance sched ule based on the p ump’s service his tory. Sc heduled maintenance is especially important to pre vent spills or leakage d ue to dia phragm failur e. Lubrication The pump is lubric ated at the factory. It is designe d to require no f urther lu bricatio n for the ...

  • Graco 3A2578B - page 16

    Torque Instruct ions Torque Instructions If fluid cover or manifo ld fasteners have b een loosened, it is important to torque the m using the followi ng procedure to improve seal ing. NOTE: Fluid cover and manifol d fasteners have a thread-lo cking adhesive patch app lied to the thr eads. If this patch is e xcessively worn, the fasteners may loose ...

  • Graco 3A2578B - page 17

    Notes Notes 3A2578B 17 ...

  • Graco 3A2578B - page 18

    Dimen sions Dimensions End Flange Models, Polypropylene and PVDF Polypropylene PVDF A 25.1 in. 63.8 cm 25.2 in. 64.0 cm B 28.7 in. 72.9 cm 28.8 in. 73.2 cm C 31.7 in. 80.5 cm 31.8 in. 80.8 cm D 3.6 in. 9.1 cm 3.6 in. 9.1 cm E 12.0 in. 30.5 cm 11.7 in. 29.7 cm F 25.6 in. 65.0 cm 25.3 in. 64.3 cm Polypropylene PVDF G 19.8 in. 50.3 cm 19.8 in. 50.3 cm ...

  • Graco 3A2578B - page 19

    Dimensions Center Flange Models, Polypropylene Only Polypropylene A 24.1 in. 61.2 cm B 27.2 in. 69.1 cm C 30.3 in. 77.0 cm D 3.1 in. 7.9 cm E 12.8 in. 32.5 cm F 26.3 in. 66.8 cm Polypropylene G 18.5 in. 47.0 cm H 7.0 in . 17.8 cm J 13.9 in. 35.3 cm K 16.3 in. 41.4 cm L 8.2 in . 20.8 cm 3A2578B 19 ...

  • Graco 3A2578B - page 20

    Performance Cha rts Performance C harts Bolt-through Diaphragms Fluid Pres sure Approximate Cycle s per Minute PSI (MPa, bar) 04 0 (151) 80 (303) 120 (454) 160 (606) 200 (757) 25 50 75 100 125 0 25 (0.17, 1.7) 50 (0.34, 3.4) 75 (0.52, 5.2) 100 (0.70, 7.0) 125 (0.86, 8.6) A B C D Fluid Flow — gpm (lpm) Operating Air Pr essure A 125 psi ( 0.86 MPa, ...

  • Graco 3A2578B - page 21

    Performa nce Cha rts Overmolded Di aphragms Fluid Pressure Approximate Cycles pe r Minute PSI (MPa, bar) A B C D 04 0 (151) 80 (303) 120 (454) 160 (606) 200 (757) 31 62 93 124 155 0 25 (0.17, 1.7) 50 (0.34, 3.4) 75 (0.52, 5.2) 100 (0.70, 7.0) 125 (0.86, 8.6) Fluid Flow — gpm (l pm) Operating Air Pres sure A 125 psi (0.86 MPa, 8. 6 bar) B 100 psi ...

  • Graco 3A2578B - page 22

    Technical Data Technical Data Husky 2200 Diaphragm Pump US Metric Maximum fluid working pressure 125 psi 0.86 MPa, 8.6 b ar Air pressure operating range 20 to 125 psi 0.14 to 0.8 6 M Pa, 1.4 to 8.6 bar Air inlet siz e 3/4 in. npt(f) Air exhaust s ize 1 in. npt(f) Fluid inlet an d outlet size (ANSI/D IN flange) 2i n 5 0m m Maximum suct ion lift (r ...

  • Graco 3A2578B - page 23

    Technical Data Maximum pump speed Standard diaph ragms 125 cycles per minute Overmolded dia phragms 155 cycles per minute Weight Polypropylen e 80 lb 36.3 kg PVDF 106 lb 48.1 kg Wetted Parts Wetted parts incl ude material( s) chosen for seat, ball, and diaphr agm opt ions, plus the pump’s material o f construction: Polypropylene or PVDF Non-wette ...

  • Graco 3A2578B - page 24

    Graco Standard Husky Pump Warranty Graco warrants all equ ipment refer enced in thi s document whic h is manufac tur ed by Graco and bearing it s name to be free from defect s in material and workmanshi p on the date of sale t o the original purchase r for use. W ith the exception of any speci al, extended, or limi ted warranty publ ished by Graco, ...

Fabbricante Graco Categoria Heat Pump

I documenti che otteniamo dal fabbricante del dispositivoGraco 3A2578B possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Graco
- manuali per l’uso 3A2578B
- schede prodotto Graco
- opuscoli
- o etichette energetiche Graco 3A2578B
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Graco 3A2578B.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Graco 3A2578B, manuali di manutenzione, brevi manuali o manuali utente Graco 3A2578B. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Graco 3A2578B.

Manuali per l’uso simili

Manuale completo del dispositivo Graco 3A2578B, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Graco 3A2578B dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Graco 3A2578B.

Il manuale per l’uso completo Graco, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Graco 3A2578B - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Graco 3A2578B, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Graco 3A2578B che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Graco 3A2578B - che ci dovrebbe aiutare nei primi passi durante l'uso Graco 3A2578B
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Graco 3A2578B
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Graco 3A2578B in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Graco 3A2578B?

Utilizza il modulo sottostante

Se non hai risolto il problema con Graco 3A2578B con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Graco 3A2578B è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)