    Operation Husky™ 2200 Air -Operated Diaphragm Pum p 3A2578B EN Polypropylene and PVDF pumps for fluid transfer applications, including high viscosity materials. For professional use only. Not for use in European explosive atmosphere locations. Importan t Safety Instru ctions Read all warni ngs and inst ruction s in this manu al and in your Repai ...

  • Graco 3A2578B - page 2

    Contents Wa rni ng s ........................................................... 3 Or der in g In fo rm ati on ........................................... 6 Related Manu a ls ................................................ 6 Co nfig ura ti on N umb er Ma tri x ............................... 7 In st al la ti on.................................... ...

  • Graco 3A2578B - page 3

    Warnings Warnings The following warnings are for th e setup, use, gro unding, mai ntenance, and repai r of thi s equipment . The exclamation p oint symbol alert s you to a general warni ng and the hazard symbols refer t o p rocedure- specific risks. When th ese symbols appear in th e body of thi s manual or on warni ng labels, refe r bac kt ot h e ...

  • Graco 3A2578B - page 4

    Warnings WARNING EQUIPMENT MISUSE HAZARD Misuse can cau se death or ser ious injury. • Do not oper ate the unit when fatigu ed or under the influence of dr ugs or alco hol. • Do not exce ed the maximum working pressur e or tempera ture rating o f the lowest r ated system compo nent. See Technical Data in all equipment manuals. • Use fluids ...

  • Graco 3A2578B - page 5

    Warnings WARNING TOXIC FLUID OR FUMES HAZARD Toxic fluids or fumes can cause s erious injury o r death if splashed in th e eyes or on skin, inhaled, or s wallowed. • Read MSDSs to know the specific hazards of th e fluids you are using. • Route exhaus t away f rom work area. If diaphragm ruptures, fluid may be exhausted in to the air. • St ...

  • Graco 3A2578B - page 6

    Ordering Inform ation Ordering Info rmation To Find Your Ne arest Distributor 1. Visit www.graco.c om . 2. Click on Where to Buy and use the Distributor Locator. To Specify the Configuration of a New Pump Please call your distributor. OR Use the On line Husky Se lector Tool on the Process Equipmen t page at www.graco.com . To Order Replacement Par ...

  • Graco 3A2578B - page 7

    Con fi guration Nu mber Matrix Configuration Number Matrix Check the identi fication plat e (ID) for th e Configuration Nu mber of your pum p. Use the following ma trix to define the compone nts of your pump. CONFIGURA TION NO. P ART NO. SERIAL NO. SERIES DA TE CODE MAX WPR PSI-bar Graco Inc., P .O. Box 1441 Mpls, MN 55440 USA MADE IN Sample C ...

  • Graco 3A2578B - page 8

    Installation Installation General Information The Typical Inst allation shown is only a gui de for selecting and in stalling system com ponents. Contac t your Graco distr ibutor for assistance in pla nning a system to suit your n eeds. Always use Genuine Graco Parts and accessories. Be sure all accessories are adequatel y sized and pressur e rated ...

  • Graco 3A2578B - page 9

    Installation Accessories/Components Not Supp lied System Components A Air supply lin e J Air inle t port (not vi sible) B Bleed-type maste r air valve (may be required for you r pump) K Air exhaust port and muf fler C Air filter/re gulator assembly L Fluid inlet port D Master air valve (to isolate th e filter/regul ator for service) M Fluid outl ...

  • Graco 3A2578B - page 10

    Installation Ground The Sys tem The equipmen t must be grounded t o reduce the risk of stati c sparking. Static sparking can cause fumes t o igni te or explode. Grounding provid es an escape wire f or the electrical current. • Always ground the entir e fluid system as described belo w. • Polypropyle ne and PVDF pumps are not conductive and are ...

  • Graco 3A2578B - page 11

    Installation Air Exhaust Ventilation If pumping tox ic fluids, you must vent the exhaust away from peo ple, ani mals, foo d handling a reas, and all sourc es of ignition. Follow all applica ble codes. NOTICE The air ex haust port is 1 in . npt(f). Do not r estrict the air exhaust port. Excessive exhaust restriction can cause errati c pump operati ...

  • Graco 3A2578B - page 12

    Installation Fluid Supply L ine 1. Use grounded, flexible fluid ho ses (E). See Ground The System, pag e 10 . 2. If the inl et fluid pressure to the pump i s more than 25% of t he outlet w orking pressu re, the ball check valves will not cl ose fast enough, resulting in i nefficient pump oper ation. Excessive inlet fluid pressure also will sho ...

  • Graco 3A2578B - page 13

    Installation Flange Connec tions The fluid inlet and ou tlet ports are 2 i n. (50 mm) raised face, ANSI /DIN PN 10 flanges. Connect 2 in. (50 mm) plast ic pipe flange t o the pump as fol lows. You will need: • Torqu e wrenc h • Adjustable w rench • 6 in. (152 mm ) diameter, 1/8 in ( 32 mm) thick PTFE gasket ,w i t hf o u r0 . 7 5i n( 1 9m ...

  • Graco 3A2578B - page 14

    Operation Operation Pressure Reli ef Procedure Follow the Pressure Relief Procedure whenever you see this symbol . This equipment stays pressuri zed until pressure is relieved manu ally. To help prevent serious injury from pressurized fl uid, such as s plashing in the eyes or on skin, fo llow the Pressure Relief Procedure when you stop pump ing an ...

  • Graco 3A2578B - page 15

    Maintenance Maintenance Maintenance Schedule Establish a p reventive maintenance sched ule based on the p ump’s service his tory. Sc heduled maintenance is especially important to pre vent spills or leakage d ue to dia phragm failur e. Lubrication The pump is lubric ated at the factory. It is designe d to require no f urther lu bricatio n for the ...

  • Graco 3A2578B - page 16

    Torque Instruct ions Torque Instructions If fluid cover or manifo ld fasteners have b een loosened, it is important to torque the m using the followi ng procedure to improve seal ing. NOTE: Fluid cover and manifol d fasteners have a thread-lo cking adhesive patch app lied to the thr eads. If this patch is e xcessively worn, the fasteners may loose ...

  • Graco 3A2578B - page 17

    Notes Notes 3A2578B 17 ...

  • Graco 3A2578B - page 18

    Dimen sions Dimensions End Flange Models, Polypropylene and PVDF Polypropylene PVDF A 25.1 in. 63.8 cm 25.2 in. 64.0 cm B 28.7 in. 72.9 cm 28.8 in. 73.2 cm C 31.7 in. 80.5 cm 31.8 in. 80.8 cm D 3.6 in. 9.1 cm 3.6 in. 9.1 cm E 12.0 in. 30.5 cm 11.7 in. 29.7 cm F 25.6 in. 65.0 cm 25.3 in. 64.3 cm Polypropylene PVDF G 19.8 in. 50.3 cm 19.8 in. 50.3 cm ...

  • Graco 3A2578B - page 19

    Dimensions Center Flange Models, Polypropylene Only Polypropylene A 24.1 in. 61.2 cm B 27.2 in. 69.1 cm C 30.3 in. 77.0 cm D 3.1 in. 7.9 cm E 12.8 in. 32.5 cm F 26.3 in. 66.8 cm Polypropylene G 18.5 in. 47.0 cm H 7.0 in . 17.8 cm J 13.9 in. 35.3 cm K 16.3 in. 41.4 cm L 8.2 in . 20.8 cm 3A2578B 19 ...

  • Graco 3A2578B - page 20

    Performance Cha rts Performance C harts Bolt-through Diaphragms Fluid Pres sure Approximate Cycle s per Minute PSI (MPa, bar) 04 0 (151) 80 (303) 120 (454) 160 (606) 200 (757) 25 50 75 100 125 0 25 (0.17, 1.7) 50 (0.34, 3.4) 75 (0.52, 5.2) 100 (0.70, 7.0) 125 (0.86, 8.6) A B C D Fluid Flow — gpm (lpm) Operating Air Pr essure A 125 psi ( 0.86 MPa, ...

  • Graco 3A2578B - page 21

    Performa nce Cha rts Overmolded Di aphragms Fluid Pressure Approximate Cycles pe r Minute PSI (MPa, bar) A B C D 04 0 (151) 80 (303) 120 (454) 160 (606) 200 (757) 31 62 93 124 155 0 25 (0.17, 1.7) 50 (0.34, 3.4) 75 (0.52, 5.2) 100 (0.70, 7.0) 125 (0.86, 8.6) Fluid Flow — gpm (l pm) Operating Air Pres sure A 125 psi (0.86 MPa, 8. 6 bar) B 100 psi ...

  • Graco 3A2578B - page 22

    Technical Data Technical Data Husky 2200 Diaphragm Pump US Metric Maximum fluid working pressure 125 psi 0.86 MPa, 8.6 b ar Air pressure operating range 20 to 125 psi 0.14 to 0.8 6 M Pa, 1.4 to 8.6 bar Air inlet siz e 3/4 in. npt(f) Air exhaust s ize 1 in. npt(f) Fluid inlet an d outlet size (ANSI/D IN flange) 2i n 5 0m m Maximum suct ion lift (r ...

  • Graco 3A2578B - page 23

    Technical Data Maximum pump speed Standard diaph ragms 125 cycles per minute Overmolded dia phragms 155 cycles per minute Weight Polypropylen e 80 lb 36.3 kg PVDF 106 lb 48.1 kg Wetted Parts Wetted parts incl ude material( s) chosen for seat, ball, and diaphr agm opt ions, plus the pump’s material o f construction: Polypropylene or PVDF Non-wette ...

  • Graco 3A2578B - page 24

    Graco Standard Husky Pump Warranty Graco warrants all equ ipment refer enced in thi s document whic h is manufac tur ed by Graco and bearing it s name to be free from defect s in material and workmanshi p on the date of sale t o the original purchase r for use. W ith the exception of any speci al, extended, or limi ted warranty publ ished by Graco, ...

Производитель Graco Категория Heat Pump

Документы, которые мы получаем от производителя устройства Graco 3A2578B мы можем разделить на несколько групп. Это в частности:
- технические чертежи Graco
- инструкции обслуживания 3A2578B
- паспорта изделия Graco
- информационные брошюры
- энергетические этикетки Graco 3A2578B
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Graco 3A2578B.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Graco 3A2578B, инструкции обслуживания, короткие инструкции или инструкции пользователя Graco 3A2578B. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Graco 3A2578B.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Graco 3A2578B, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Graco 3A2578B пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Graco 3A2578B.

Полная инструкция обслуживания Graco, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Graco 3A2578B - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Graco 3A2578B, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Graco 3A2578B, которое найдем в данном документе
3. Советы по использованию основных функций устройства Graco 3A2578B - которые должны облегчить нам первые шаги во время использования Graco 3A2578B
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Graco 3A2578B
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Graco 3A2578B в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Graco 3A2578B?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Graco 3A2578B, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Graco 3A2578B со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)