    Universal T elephone Interface UTI1 Model Inst allation and Use Manual © 2004 Bogen Communications, Inc. All rights reserved. Specifications subject to change without notice. 54-2095-0 1 A 0406 ...

  • Bogen UTI1 - page 2

    © 2004 Bogen Communications, Inc. All Rights Reser ved. Printed in T aiwan. Notice Every effort was made to ensure that the information in this manual was complete and accurate at the time of printing. How ev er , information is subject to change. FCC Statement (P art 1 5) - Radio Frequency Interf erence The Universal T elephone Interface (UTI 1 ) ...

  • Bogen UTI1 - page 3

    Contents UTI 1 F eature Callouts ..........................................................................................................4 Introduction ................................................................................................................... .........5 V oice Channel ...................................................... ...

  • Bogen UTI1 - page 4

    4 UTI 1 F eatur e Callouts 1 . P o wer Indicator - Illuminates when A C power has been applied to the unit. 2. AUX Contact T erminals - Provide connections f or normally open and normally closed contact closur es. The contact closure can be pr ogrammed to activate during paging, night ring, tone, ov erride , or any combination (r efer to System Pro ...

  • Bogen UTI1 - page 5

    5 Intr oduction The UTI 1 Paging System is a paging and signaling system. The system provides the f ollowing f eatures and functions: V oice Channel • Single-zone paging • T elephone interfaces: - loop start trunk - ground start trunk - station access (analog ring-up) - page port contact closure activation - page port voice activation • Overr ...

  • Bogen UTI1 - page 6

    Installation W all Mounting Mounting to a plyw ood backboard or studs: 1 . Hold the unit lev el against the surface to which it will be mounted. 2. Mark where the mounting scr ews should be positioned. 3. Set the unit aside and install the scre ws leaving about 1 / 4 " of the scr ews sticking out of the surface. 4. Slip the unit ov er the scre ...

  • Bogen UTI1 - page 7

    T elephone Interface Wiring Connections & Setup T elephone System Connections The UTI 1 connects to virtually any telephone system: PBX station lines and CO lines, PBX loop star t trunk por ts, PBX ground start trunk ports, and page ports. Interface installation consists of setting the slide switches and connecting with modular (RJ 11 ) telepho ...

  • Bogen UTI1 - page 8

    8 PBX Gr ound Start T runk P ort In this configuration, the unit supplies 24V talk batter y , a contact in the Tip circuit, and loop curr ent detector in the ring line. When the ground start trunk grounds Ring, the unit r esponds by closing the connection to Tip, which completes the access procedur e . When the loop is opened, the page ends. The un ...

  • Bogen UTI1 - page 9

    9 PBX P age P or t V O X In this configuration, the unit activates when audio on the page input is detected. Loss of audio allows the VO X timer to expire and ends the page. Mak e sure that the po w er is disconnected and all other connections are completed bef or e pr oceeding. Move the slide switches on the UTI 1 to the positions shown belo w . U ...

  • Bogen UTI1 - page 10

    10 Over ride Input The Over ride is a non-pr ogrammable featur e that lets the caller tak e priority over all paging functions and mak e a page to all speak ers. The feature can be activated using a loop start trunk or dedicated telephone. The center two conductors interface dir ectly to a Loop Star t T runk or a dedicated phone . When the trunk be ...

  • Bogen UTI1 - page 11

    11 Other Connections Night Ringer The UTI 1 night ringer signaling featur e is designed to alert personnel to incoming calls after normal business hours.The feature is activated b y a contact closure fr om the PBX. The night ringer normally sounds a simulated ring tone, but can be programmed to sound a chime tone. T o ph ysically connect the night ...

  • Bogen UTI1 - page 12

    12 Contr ols P aging Le v el The UTI 1 has contr ols for adjusting the audio lev el of each output independently . These ser ve as master le vel contr ols that allow for o verall system contr ol. Setting the initial volume to half is a good starting point. If the speak ers hav e their own le v el control, then the installer will hav e to determine ...

  • Bogen UTI1 - page 13

    13 T ones Pre-Announce/Conf irmation T one This tone can be set to be heard at the speak ers being paged or the calling telephone or both. It is either a chime or beep (default). The pre-announce/conf irmation tone can also be inhibited. See System Progr amming to change or inhibit this tone. T one T rigger This tone is activated when the TN and C ...

  • Bogen UTI1 - page 14

    14 System Pr o gramming System programming lets y ou set cer tain UTI 1 options and tone features using the DTMF k eys of a telephone. All programming is accomplished thr ough the Override jack on the UTI 1 . T o program the UTI 1 system, follow these instructions: 1 . Place the PR OGRAM/R UN switch to the PR OGRAM position. The green LED will illu ...

  • Bogen UTI1 - page 15

    15 AUX Rela y Contact The UTI 1 allows the installer to pr ogram a number of different parameters to contr ol the way in which the A UX rela y contacts activate. The UTI 1 allows pr ogramming of which input events (Ov erride, T one T rigger , Page , and Night Ring) it will respond to , whether it will respond to the ev ent only (Event Driv en Mode) ...

  • Bogen UTI1 - page 16

    16 Example 1 : Emergency T one/Emergency Announcement Bypass The tone trigger and override inputs are used to pro vide emergency tones and live emergenc y announcements and when this happens any local attenuators are to be bypassed to ensure that emerg ency announcements can be heard. The AUX rela y contacts will signal the attenuators to go into t ...

  • Bogen UTI1 - page 17

    17 F eatur e Codes & Defaults Feature Feature Code Dat a Default Pre-Announce / Confirmation T one Handset & Outputs Handset only Outputs only Inhibit Beep Chime 01 02 03 04 05 06 01 05 Override T one Disable Enable 08 09 08 T runk Disconnect Disable Enable 14 15 15 Timers Default T imer VOX T imer 50 51 00 - 99 0 - 9 03 6 T one T rigger Sl ...

  • Bogen UTI1 - page 18

    18 Specifications Input Impedance: 600 ohms Input Lev el: - 1 0 dBm nominal V O X Sensitivity: -30 dBm Music Source Input Impedance: 8 to 600 ohms Music Input Lev el: - 1 0 dBm Output Impedance: 8 ohms Output Lev el: - 1 0 dBm nominal Contact Closure: 2A @ 30V DC 0.6A @ 1 25V A C DC Output: 1 A @ 24V DC V oltage: 1 20V A C Curr ent: 0.5A T emperatu ...

  • Bogen UTI1 - page 19

    19 Block Dia gram ...

  • Bogen UTI1 - page 20

    50 S pring S treet, Ramsey , NJ 07446, U.S.A. T el. 201-934-8500, Fax: 201-934-9832, www .bogen.com Limited W arranty The UTI1 is warranted to be free from defects in material or workmanship for two (2) years from the date of sale to the original purchaser . Any part of the product covered by this warranty that, with normal installation and use, be ...

Fabbricante Bogen Categoria Telephone

I documenti che otteniamo dal fabbricante del dispositivoBogen UTI1 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Bogen
- manuali per l’uso UTI1
- schede prodotto Bogen
- opuscoli
- o etichette energetiche Bogen UTI1
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Bogen UTI1.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Bogen UTI1, manuali di manutenzione, brevi manuali o manuali utente Bogen UTI1. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Bogen UTI1.

Manuali per l’uso simili

Manuale completo del dispositivo Bogen UTI1, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Bogen UTI1 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Bogen UTI1.

Il manuale per l’uso completo Bogen, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Bogen UTI1 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Bogen UTI1, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Bogen UTI1 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Bogen UTI1 - che ci dovrebbe aiutare nei primi passi durante l'uso Bogen UTI1
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Bogen UTI1
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Bogen UTI1 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Bogen UTI1?

Utilizza il modulo sottostante

Se non hai risolto il problema con Bogen UTI1 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Bogen UTI1 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)