  • Bogen UTI1 - page 1

    Universal T elephone Interface UTI1 Model Inst allation and Use Manual © 2004 Bogen Communications, Inc. All rights reserved. Specifications subject to change without notice. 54-2095-0 1 A 0406 ...

  • Bogen UTI1 - page 2

    © 2004 Bogen Communications, Inc. All Rights Reser ved. Printed in T aiwan. Notice Every effort was made to ensure that the information in this manual was complete and accurate at the time of printing. How ev er , information is subject to change. FCC Statement (P art 1 5) - Radio Frequency Interf erence The Universal T elephone Interface (UTI 1 ) ...

  • Bogen UTI1 - page 3

    Contents UTI 1 F eature Callouts ..........................................................................................................4 Introduction ................................................................................................................... .........5 V oice Channel ...................................................... ...

  • Bogen UTI1 - page 4

    4 UTI 1 F eatur e Callouts 1 . P o wer Indicator - Illuminates when A C power has been applied to the unit. 2. AUX Contact T erminals - Provide connections f or normally open and normally closed contact closur es. The contact closure can be pr ogrammed to activate during paging, night ring, tone, ov erride , or any combination (r efer to System Pro ...

  • Bogen UTI1 - page 5

    5 Intr oduction The UTI 1 Paging System is a paging and signaling system. The system provides the f ollowing f eatures and functions: V oice Channel • Single-zone paging • T elephone interfaces: - loop start trunk - ground start trunk - station access (analog ring-up) - page port contact closure activation - page port voice activation • Overr ...

  • Bogen UTI1 - page 6

    Installation W all Mounting Mounting to a plyw ood backboard or studs: 1 . Hold the unit lev el against the surface to which it will be mounted. 2. Mark where the mounting scr ews should be positioned. 3. Set the unit aside and install the scre ws leaving about 1 / 4 " of the scr ews sticking out of the surface. 4. Slip the unit ov er the scre ...

  • Bogen UTI1 - page 7

    T elephone Interface Wiring Connections & Setup T elephone System Connections The UTI 1 connects to virtually any telephone system: PBX station lines and CO lines, PBX loop star t trunk por ts, PBX ground start trunk ports, and page ports. Interface installation consists of setting the slide switches and connecting with modular (RJ 11 ) telepho ...

  • Bogen UTI1 - page 8

    8 PBX Gr ound Start T runk P ort In this configuration, the unit supplies 24V talk batter y , a contact in the Tip circuit, and loop curr ent detector in the ring line. When the ground start trunk grounds Ring, the unit r esponds by closing the connection to Tip, which completes the access procedur e . When the loop is opened, the page ends. The un ...

  • Bogen UTI1 - page 9

    9 PBX P age P or t V O X In this configuration, the unit activates when audio on the page input is detected. Loss of audio allows the VO X timer to expire and ends the page. Mak e sure that the po w er is disconnected and all other connections are completed bef or e pr oceeding. Move the slide switches on the UTI 1 to the positions shown belo w . U ...

  • Bogen UTI1 - page 10

    10 Over ride Input The Over ride is a non-pr ogrammable featur e that lets the caller tak e priority over all paging functions and mak e a page to all speak ers. The feature can be activated using a loop start trunk or dedicated telephone. The center two conductors interface dir ectly to a Loop Star t T runk or a dedicated phone . When the trunk be ...

  • Bogen UTI1 - page 11

    11 Other Connections Night Ringer The UTI 1 night ringer signaling featur e is designed to alert personnel to incoming calls after normal business hours.The feature is activated b y a contact closure fr om the PBX. The night ringer normally sounds a simulated ring tone, but can be programmed to sound a chime tone. T o ph ysically connect the night ...

  • Bogen UTI1 - page 12

    12 Contr ols P aging Le v el The UTI 1 has contr ols for adjusting the audio lev el of each output independently . These ser ve as master le vel contr ols that allow for o verall system contr ol. Setting the initial volume to half is a good starting point. If the speak ers hav e their own le v el control, then the installer will hav e to determine ...

  • Bogen UTI1 - page 13

    13 T ones Pre-Announce/Conf irmation T one This tone can be set to be heard at the speak ers being paged or the calling telephone or both. It is either a chime or beep (default). The pre-announce/conf irmation tone can also be inhibited. See System Progr amming to change or inhibit this tone. T one T rigger This tone is activated when the TN and C ...

  • Bogen UTI1 - page 14

    14 System Pr o gramming System programming lets y ou set cer tain UTI 1 options and tone features using the DTMF k eys of a telephone. All programming is accomplished thr ough the Override jack on the UTI 1 . T o program the UTI 1 system, follow these instructions: 1 . Place the PR OGRAM/R UN switch to the PR OGRAM position. The green LED will illu ...

  • Bogen UTI1 - page 15

    15 AUX Rela y Contact The UTI 1 allows the installer to pr ogram a number of different parameters to contr ol the way in which the A UX rela y contacts activate. The UTI 1 allows pr ogramming of which input events (Ov erride, T one T rigger , Page , and Night Ring) it will respond to , whether it will respond to the ev ent only (Event Driv en Mode) ...

  • Bogen UTI1 - page 16

    16 Example 1 : Emergency T one/Emergency Announcement Bypass The tone trigger and override inputs are used to pro vide emergency tones and live emergenc y announcements and when this happens any local attenuators are to be bypassed to ensure that emerg ency announcements can be heard. The AUX rela y contacts will signal the attenuators to go into t ...

  • Bogen UTI1 - page 17

    17 F eatur e Codes & Defaults Feature Feature Code Dat a Default Pre-Announce / Confirmation T one Handset & Outputs Handset only Outputs only Inhibit Beep Chime 01 02 03 04 05 06 01 05 Override T one Disable Enable 08 09 08 T runk Disconnect Disable Enable 14 15 15 Timers Default T imer VOX T imer 50 51 00 - 99 0 - 9 03 6 T one T rigger Sl ...

  • Bogen UTI1 - page 18

    18 Specifications Input Impedance: 600 ohms Input Lev el: - 1 0 dBm nominal V O X Sensitivity: -30 dBm Music Source Input Impedance: 8 to 600 ohms Music Input Lev el: - 1 0 dBm Output Impedance: 8 ohms Output Lev el: - 1 0 dBm nominal Contact Closure: 2A @ 30V DC 0.6A @ 1 25V A C DC Output: 1 A @ 24V DC V oltage: 1 20V A C Curr ent: 0.5A T emperatu ...

  • Bogen UTI1 - page 19

    19 Block Dia gram ...

  • Bogen UTI1 - page 20

    50 S pring S treet, Ramsey , NJ 07446, U.S.A. T el. 201-934-8500, Fax: 201-934-9832, www .bogen.com Limited W arranty The UTI1 is warranted to be free from defects in material or workmanship for two (2) years from the date of sale to the original purchaser . Any part of the product covered by this warranty that, with normal installation and use, be ...

メーカー Bogen カテゴリー Telephone

Bogen UTI1のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- UTI1の取扱説明書
- Bogenの製品カード
- パンフレット
- またはBogen UTI1の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Bogen UTI1の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Bogen UTI1の取り付け説明書、サービスマニュアル、簡易説明書、またはBogen UTI1のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Bogen UTI1の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Bogen UTI1デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBogen UTI1を使用するのを助ける技術的文書のことです。説明書は通常、全てのBogen UTI1ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Bogenの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Bogen UTI1の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBogen UTI1の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Bogen UTI1に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Bogen UTI1デバイスの基本機能を使うにあたってのヒント。 Bogen UTI1のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Bogen UTI1に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBogen UTI1のメーカー/サービスへの連絡先に関する情報。

Bogen UTI1についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBogen UTI1の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBogen UTI1で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)