    FL R 1000 & 100 0- BR S eri es Flow Sensors & Meters For Ga ses ...

  • Omega Engineering FLR1000 - page 2

    ...

  • Omega Engineering FLR1000 - page 3

    pg. 3 of 29 READ THIS MANUAL COMPLETELY BEFORE ATTEMPTING TO CONNECT OR OPERATE YOUR FLOW SENSO R. FAI LURE TO DO SO MAY RE SULT IN INJURY TO YOU OR DAMA GE TO THE FLO W SENSOR. TABL E OF CONTENT S A. Introduction ..... ..... .... .... ..... ....... .... .... ..... .... ....... .... ..... .... .... ....... .... .. 4 1. Unpacking .... ..... .... ... ...

  • Omega Engineering FLR1000 - page 4

    pg. 4 of 29 A. Introduction 1. Un pa cking All units ar e suit ably pack aged to preve nt dam age during s hippin g. If e xtern a l da mage is no te d upon rec e ipt of t he pack age , please con tac t Omega Eng ineering immedi atel y. Open the p ackage from the top, t aki ng care not to cut too deeply into t he package. Remo ve all the docum entat ...

  • Omega Engineering FLR1000 - page 5

    pg. 5 of 29 pr o ve n de s i gn m i n im i ze s ze r o dr if t wh i l e ma int a in in g fa st re s p on se an d line a r o u tp uts wit h virt ually no mai ntenanc e. Flow is me a sur ed using a mi niatur e t u rbine wh eel similar i n size to a U.S. dime (16 mm diameter, 0.75 mm thick). Th e micro -turbine w heel is supported o n a very sm all sa ...

  • Omega Engineering FLR1000 - page 6

    pg. 6 of 29 1. General Co nsider ations It is recomm end e d th at a saf e ty s hut-off valv e be inst alled u pstream of (b efor e) the s en s or . All w e tted part s sh ould be che cked for com pati bili ty w ith the gas to be use d. If the re are any inc ompat ibi litie s eg . h ighly cor rosi ve gas , then the un it m ay be da mage d or fa il ...

  • Omega Engineering FLR1000 - page 7

    pg. 7 of 29 3. Tubi n g C onnections CAUT ION: D O NO T FLOW ANY L IQU ID THR OUG H A GAS FLOW SEN SOR OR FLO W MET ER. THI S WILL S ERIOUS LY EFFE CT TH E PERF ORMAN C E AND VOI D THE W ARRA N T Y. CAUT ION: D O NO T FLOW A HIGH PRE SSURE GAS THROUGH THE SENSOR. A BURST OF HIGH PRESSURE GAS MAY CAU SE TH E UNIT TO B E DAMAGED. A L WAYS FL OW GA S ...

  • Omega Engineering FLR1000 - page 8

    pg. 8 of 29 Clos e Up of Labe l Sh owi ng Flow D ir ect ion (FLR 1000 shown, other models simi lar) The tubing ID should be as large a s possible to a void r e strictio n s and turbul ence. F or th e best r esul ts, a st raight lengt h of t ubi ng befor e the u nit is recommend e d. This sho uld be 2 0 times the t u bing I.D. or gr eater 4. El e ct ...

  • Omega Engineering FLR1000 - page 9

    pg. 9 of 29 Units ar e suppli ed wit h an integr al 4 pin connect or. Connections to t he u n it are m a de usi ng a mati ng cable as sembly o r power ad apter pack age as detailed in t he follo wing sectio n s. A connector pi n a nd wir e color cross reference m a y also be fou n d in Appe n dix F (Page 18 ) of this manual. b) Conne c t in g a Cab ...

  • Omega Engineering FLR1000 - page 10

    pg. 10 of 2 9 c) Electric al Connecti ons – Voltage Output Units The cabl e assembly should be connect ed to the sensor as d e tailed i n secti on 5 (b) abo ve. Do not appl y p ower to t he senso r unti l all th e connections have been m a de and checked. Electrical connectio ns should be made as foll ows: Wiri ng Schem atic For Vo ltage Output U ...

  • Omega Engineering FLR1000 - page 11

    pg. 11 of 2 9 d) Us ing a 0 - 5VD C Ou tp ut Pow er A dap te r Pa ck age. An opti onal 0-5V DC Output Power A dapt e r Pack age is avail a ble for u se with the FLR 1000 se ries (not the FLR 1000 - ST-I ). This consists of a power source (115VAC or 230VAC) and cable assembl y with pig-t ail (soldered w ir e ) en d s fo r t he sig n a l ou t pu t . ...

  • Omega Engineering FLR1000 - page 12

    pg. 12 of 2 9 C. Operation CAUT ION: D O NO T FLOW ANY L IQU ID THR OUG H A GAS FLOW SEN SOR OR FLO W MET ER. THI S WILL S ERIOUS LY EFFE CT TH E PERF ORMAN C E AND VOI D THE W ARRA N T Y. 1. St ar t Up Before ap plying power to the unit check a ll tubing and electric a l connections. Once correct inst a llation is verifi e d switch on t he power. ...

  • Omega Engineering FLR1000 - page 13

    pg. 13 of 2 9 100-500 ml/min and in l/min for flo w ran ges of 0.2 – 1.0 L/min and above. The displ a y will only operate if po wer is applied to t he unit. Flow readings m ay be taken direct ly from the display or by m onitoring the 0-5V DC analog o utp ut prov id ed by usi ng a cable assembly or pow e r ad apt er p ack ag e (s ee ab ov e) . LCD ...

  • Omega Engineering FLR1000 - page 14

    pg. 14 of 2 9 4. Zer o Adjustm ents It is im possible for th ere to b e any zero drift so zero adj u stment s are neve r required. 5. Re ca li brat i on Pleas e cont act th e Omeg a Engi nee ring S ervi ce Dep artm ent if yo ur flo w sensor or flow m eter needs r e calib ration. 6. Using Flow Senso rs or Flow Met ers with Differ ent Gases Th e FL R ...

  • Omega Engineering FLR1000 - page 15

    pg. 15 of 2 9 If t he uni t h as a flo w re adi ng o f 2 00 ml /mi n th en t he co rr ect ed flo w reading (for C O 2) would be: Corrected Flow = 2 00 X 0.88 = 176 ml/min CAUTION:. The use of co rrection fac tors c an be subj ect to inaccur acy and e rrors of up to ±10%. Please co ntact th e O me ga En gin ee r i n g Se rv i ce D e pa rt m e n t i ...

  • Omega Engineering FLR1000 - page 16

    pg. 16 of 2 9 D. Maintenance and Product Care 1. Gen e r al CAUT ION: D o not disass emble yo ur unit for an y re ason. If the uni t a ppear s to be malf unc ti oni n g pl ea se co nta ct th e Om ega En gin eer i ng Ser v ic e De par t me nt. The FLR 1000 Series of flow me ters and sensors require n o periodic mai ntenanc e i f us e d wi thin th e ...

  • Omega Engineering FLR1000 - page 17

    pg. 17 of 2 9 E. Specific ations For Gas Units FLR100 0 FLR100 0-D FLR100 0-BR-D Display None 3.5 Digit LCD, 0.39” (10mm) high digits Ac cur a cy (including linearity) ±3.0% Full Scale* Repeatability ±0.5% Full Scale* Pressure Rating 40 psig (2.8 ba r) Temperature Rating Operating Range: 5 to 55ºC Storage Range: 0 to 70ºC Tem pera tur e Sens ...

  • Omega Engineering FLR1000 - page 18

    pg. 18 of 2 9 F. Connect or Pin And Wire Color Cross Re fe rence Pin Confi guratio n for C onnec tor Socket and Connec tor Pin Cable Wi re C ol or Descri pt io n 1 Black Signal & Power Negative (Gro und) 2 Whit e Volt a ge Output 3 Red Power Posit ive 4 Green Not Used ...

  • Omega Engineering FLR1000 - page 19

    pg. 19 of 2 9 G. Dimensions ALL DIMENS ION S IN INC HES (MILL IME TER S IN BRACKE TS) FLR 1000 For G ases 20-200 ml/min To 1.0-5.0 l/ min Units 1/4” Ace t al Fi tti ngs Sho wn ...

  • Omega Engineering FLR1000 - page 20

    pg. 20 of 2 9 FLR 1000 For G ases 2. 0- 10 .0 l/m in Un it s 1/4” Ace t al Fi tti ngs Sho wn ...

  • Omega Engineering FLR1000 - page 21

    pg. 21 of 2 9 FLR 1000 For G ases 4. 0- 20 .0 l/m i n To 10 0- 50 0 l /m in Un it s 1/2” Ace t al Fi tti ngs Sho wn ...

  • Omega Engineering FLR1000 - page 22

    pg. 22 of 2 9 FLR 1000-D For Gases 20-200 ml/min To 1.0-5.0 l/ min Units 1/4” Ace t al Fi tti ngs Sho wn ...

  • Omega Engineering FLR1000 - page 23

    pg. 23 of 2 9 FLR 1000-D For Gases 2. 0- 10 .0 l/m in Un it s 1/4” Ace t al Fi tti ngs Sho wn ...

  • Omega Engineering FLR1000 - page 24

    pg. 24 of 2 9 FLR 1000-D For Gases 4. 0- 20 .0 l/m i n To 10 0- 50 0 l /m in Un it s 1/2” Ace t al Fi tti ngs Sho wn ...

  • Omega Engineering FLR1000 - page 25

    pg. 25 of 2 9 FLR 1000-BR-D For Gases 20-200 ml/min To 1.0-5.0 l/ min Units 1/4” Bra ss Fitti ngs Sho wn ...

  • Omega Engineering FLR1000 - page 26

    pg. 26 of 2 9 H. Troubleshooting Guide Symp tom Possible Cause Method of Correct ion Unit L eaks Fitti ngs not tig ht e noug h. Sensor a ssemb ly cracked Tighten fittings (s ee section B4) Unit m us t be r e turne d fo r repair (se e Section J) No ou tput signa l or flow indicat ion No power or low power No flow passing through unit Output shorted ...

  • Omega Engineering FLR1000 - page 27

    pg. 27 of 2 9 Symp tom Possible Cause Method of Correct ion Flow indication is no t linear a nd o utput too low a t lower flo ws At tem pting t o mea sure flo ws belo w t he spec ified min imum fo r t he uni t Mois ture o r liq u i d in sen sor Mech anical se nsor as sem bly damag ed Use hig her f low rat es Remove moist ure and allow sens o r to d ...

  • Omega Engineering FLR1000 - page 28

    pg. 28 of 2 9 . ...

  • Omega Engineering FLR1000 - page 29

    M4575 /0807 pg . 29 of 29 ...

Fabbricante Omega Engineering Categoria Stud Sensor

I documenti che otteniamo dal fabbricante del dispositivoOmega Engineering FLR1000 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Omega Engineering
- manuali per l’uso FLR1000
- schede prodotto Omega Engineering
- opuscoli
- o etichette energetiche Omega Engineering FLR1000
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Omega Engineering FLR1000.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Omega Engineering FLR1000, manuali di manutenzione, brevi manuali o manuali utente Omega Engineering FLR1000. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Omega Engineering FLR1000.

Manuale completo del dispositivo Omega Engineering FLR1000, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Omega Engineering FLR1000 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Omega Engineering FLR1000.

Il manuale per l’uso completo Omega Engineering, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Omega Engineering FLR1000 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Omega Engineering FLR1000, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Omega Engineering FLR1000 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Omega Engineering FLR1000 - che ci dovrebbe aiutare nei primi passi durante l'uso Omega Engineering FLR1000
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Omega Engineering FLR1000
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Omega Engineering FLR1000 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Omega Engineering FLR1000?

Utilizza il modulo sottostante

Se non hai risolto il problema con Omega Engineering FLR1000 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Omega Engineering FLR1000 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)