  • Omega Engineering FLR1000 - page 1

    FL R 1000 & 100 0- BR S eri es Flow Sensors & Meters For Ga ses ...

  • Omega Engineering FLR1000 - page 2

    ...

  • Omega Engineering FLR1000 - page 3

    pg. 3 of 29 READ THIS MANUAL COMPLETELY BEFORE ATTEMPTING TO CONNECT OR OPERATE YOUR FLOW SENSO R. FAI LURE TO DO SO MAY RE SULT IN INJURY TO YOU OR DAMA GE TO THE FLO W SENSOR. TABL E OF CONTENT S A. Introduction ..... ..... .... .... ..... ....... .... .... ..... .... ....... .... ..... .... .... ....... .... .. 4 1. Unpacking .... ..... .... ... ...

  • Omega Engineering FLR1000 - page 4

    pg. 4 of 29 A. Introduction 1. Un pa cking All units ar e suit ably pack aged to preve nt dam age during s hippin g. If e xtern a l da mage is no te d upon rec e ipt of t he pack age , please con tac t Omega Eng ineering immedi atel y. Open the p ackage from the top, t aki ng care not to cut too deeply into t he package. Remo ve all the docum entat ...

  • Omega Engineering FLR1000 - page 5

    pg. 5 of 29 pr o ve n de s i gn m i n im i ze s ze r o dr if t wh i l e ma int a in in g fa st re s p on se an d line a r o u tp uts wit h virt ually no mai ntenanc e. Flow is me a sur ed using a mi niatur e t u rbine wh eel similar i n size to a U.S. dime (16 mm diameter, 0.75 mm thick). Th e micro -turbine w heel is supported o n a very sm all sa ...

  • Omega Engineering FLR1000 - page 6

    pg. 6 of 29 1. General Co nsider ations It is recomm end e d th at a saf e ty s hut-off valv e be inst alled u pstream of (b efor e) the s en s or . All w e tted part s sh ould be che cked for com pati bili ty w ith the gas to be use d. If the re are any inc ompat ibi litie s eg . h ighly cor rosi ve gas , then the un it m ay be da mage d or fa il ...

  • Omega Engineering FLR1000 - page 7

    pg. 7 of 29 3. Tubi n g C onnections CAUT ION: D O NO T FLOW ANY L IQU ID THR OUG H A GAS FLOW SEN SOR OR FLO W MET ER. THI S WILL S ERIOUS LY EFFE CT TH E PERF ORMAN C E AND VOI D THE W ARRA N T Y. CAUT ION: D O NO T FLOW A HIGH PRE SSURE GAS THROUGH THE SENSOR. A BURST OF HIGH PRESSURE GAS MAY CAU SE TH E UNIT TO B E DAMAGED. A L WAYS FL OW GA S ...

  • Omega Engineering FLR1000 - page 8

    pg. 8 of 29 Clos e Up of Labe l Sh owi ng Flow D ir ect ion (FLR 1000 shown, other models simi lar) The tubing ID should be as large a s possible to a void r e strictio n s and turbul ence. F or th e best r esul ts, a st raight lengt h of t ubi ng befor e the u nit is recommend e d. This sho uld be 2 0 times the t u bing I.D. or gr eater 4. El e ct ...

  • Omega Engineering FLR1000 - page 9

    pg. 9 of 29 Units ar e suppli ed wit h an integr al 4 pin connect or. Connections to t he u n it are m a de usi ng a mati ng cable as sembly o r power ad apter pack age as detailed in t he follo wing sectio n s. A connector pi n a nd wir e color cross reference m a y also be fou n d in Appe n dix F (Page 18 ) of this manual. b) Conne c t in g a Cab ...

  • Omega Engineering FLR1000 - page 10

    pg. 10 of 2 9 c) Electric al Connecti ons – Voltage Output Units The cabl e assembly should be connect ed to the sensor as d e tailed i n secti on 5 (b) abo ve. Do not appl y p ower to t he senso r unti l all th e connections have been m a de and checked. Electrical connectio ns should be made as foll ows: Wiri ng Schem atic For Vo ltage Output U ...

  • Omega Engineering FLR1000 - page 11

    pg. 11 of 2 9 d) Us ing a 0 - 5VD C Ou tp ut Pow er A dap te r Pa ck age. An opti onal 0-5V DC Output Power A dapt e r Pack age is avail a ble for u se with the FLR 1000 se ries (not the FLR 1000 - ST-I ). This consists of a power source (115VAC or 230VAC) and cable assembl y with pig-t ail (soldered w ir e ) en d s fo r t he sig n a l ou t pu t . ...

  • Omega Engineering FLR1000 - page 12

    pg. 12 of 2 9 C. Operation CAUT ION: D O NO T FLOW ANY L IQU ID THR OUG H A GAS FLOW SEN SOR OR FLO W MET ER. THI S WILL S ERIOUS LY EFFE CT TH E PERF ORMAN C E AND VOI D THE W ARRA N T Y. 1. St ar t Up Before ap plying power to the unit check a ll tubing and electric a l connections. Once correct inst a llation is verifi e d switch on t he power. ...

  • Omega Engineering FLR1000 - page 13

    pg. 13 of 2 9 100-500 ml/min and in l/min for flo w ran ges of 0.2 – 1.0 L/min and above. The displ a y will only operate if po wer is applied to t he unit. Flow readings m ay be taken direct ly from the display or by m onitoring the 0-5V DC analog o utp ut prov id ed by usi ng a cable assembly or pow e r ad apt er p ack ag e (s ee ab ov e) . LCD ...

  • Omega Engineering FLR1000 - page 14

    pg. 14 of 2 9 4. Zer o Adjustm ents It is im possible for th ere to b e any zero drift so zero adj u stment s are neve r required. 5. Re ca li brat i on Pleas e cont act th e Omeg a Engi nee ring S ervi ce Dep artm ent if yo ur flo w sensor or flow m eter needs r e calib ration. 6. Using Flow Senso rs or Flow Met ers with Differ ent Gases Th e FL R ...

  • Omega Engineering FLR1000 - page 15

    pg. 15 of 2 9 If t he uni t h as a flo w re adi ng o f 2 00 ml /mi n th en t he co rr ect ed flo w reading (for C O 2) would be: Corrected Flow = 2 00 X 0.88 = 176 ml/min CAUTION:. The use of co rrection fac tors c an be subj ect to inaccur acy and e rrors of up to ±10%. Please co ntact th e O me ga En gin ee r i n g Se rv i ce D e pa rt m e n t i ...

  • Omega Engineering FLR1000 - page 16

    pg. 16 of 2 9 D. Maintenance and Product Care 1. Gen e r al CAUT ION: D o not disass emble yo ur unit for an y re ason. If the uni t a ppear s to be malf unc ti oni n g pl ea se co nta ct th e Om ega En gin eer i ng Ser v ic e De par t me nt. The FLR 1000 Series of flow me ters and sensors require n o periodic mai ntenanc e i f us e d wi thin th e ...

  • Omega Engineering FLR1000 - page 17

    pg. 17 of 2 9 E. Specific ations For Gas Units FLR100 0 FLR100 0-D FLR100 0-BR-D Display None 3.5 Digit LCD, 0.39” (10mm) high digits Ac cur a cy (including linearity) ±3.0% Full Scale* Repeatability ±0.5% Full Scale* Pressure Rating 40 psig (2.8 ba r) Temperature Rating Operating Range: 5 to 55ºC Storage Range: 0 to 70ºC Tem pera tur e Sens ...

  • Omega Engineering FLR1000 - page 18

    pg. 18 of 2 9 F. Connect or Pin And Wire Color Cross Re fe rence Pin Confi guratio n for C onnec tor Socket and Connec tor Pin Cable Wi re C ol or Descri pt io n 1 Black Signal & Power Negative (Gro und) 2 Whit e Volt a ge Output 3 Red Power Posit ive 4 Green Not Used ...

  • Omega Engineering FLR1000 - page 19

    pg. 19 of 2 9 G. Dimensions ALL DIMENS ION S IN INC HES (MILL IME TER S IN BRACKE TS) FLR 1000 For G ases 20-200 ml/min To 1.0-5.0 l/ min Units 1/4” Ace t al Fi tti ngs Sho wn ...

  • Omega Engineering FLR1000 - page 20

    pg. 20 of 2 9 FLR 1000 For G ases 2. 0- 10 .0 l/m in Un it s 1/4” Ace t al Fi tti ngs Sho wn ...

  • Omega Engineering FLR1000 - page 21

    pg. 21 of 2 9 FLR 1000 For G ases 4. 0- 20 .0 l/m i n To 10 0- 50 0 l /m in Un it s 1/2” Ace t al Fi tti ngs Sho wn ...

  • Omega Engineering FLR1000 - page 22

    pg. 22 of 2 9 FLR 1000-D For Gases 20-200 ml/min To 1.0-5.0 l/ min Units 1/4” Ace t al Fi tti ngs Sho wn ...

  • Omega Engineering FLR1000 - page 23

    pg. 23 of 2 9 FLR 1000-D For Gases 2. 0- 10 .0 l/m in Un it s 1/4” Ace t al Fi tti ngs Sho wn ...

  • Omega Engineering FLR1000 - page 24

    pg. 24 of 2 9 FLR 1000-D For Gases 4. 0- 20 .0 l/m i n To 10 0- 50 0 l /m in Un it s 1/2” Ace t al Fi tti ngs Sho wn ...

  • Omega Engineering FLR1000 - page 25

    pg. 25 of 2 9 FLR 1000-BR-D For Gases 20-200 ml/min To 1.0-5.0 l/ min Units 1/4” Bra ss Fitti ngs Sho wn ...

  • Omega Engineering FLR1000 - page 26

    pg. 26 of 2 9 H. Troubleshooting Guide Symp tom Possible Cause Method of Correct ion Unit L eaks Fitti ngs not tig ht e noug h. Sensor a ssemb ly cracked Tighten fittings (s ee section B4) Unit m us t be r e turne d fo r repair (se e Section J) No ou tput signa l or flow indicat ion No power or low power No flow passing through unit Output shorted ...

  • Omega Engineering FLR1000 - page 27

    pg. 27 of 2 9 Symp tom Possible Cause Method of Correct ion Flow indication is no t linear a nd o utput too low a t lower flo ws At tem pting t o mea sure flo ws belo w t he spec ified min imum fo r t he uni t Mois ture o r liq u i d in sen sor Mech anical se nsor as sem bly damag ed Use hig her f low rat es Remove moist ure and allow sens o r to d ...

  • Omega Engineering FLR1000 - page 28

    pg. 28 of 2 9 . ...

  • Omega Engineering FLR1000 - page 29

    M4575 /0807 pg . 29 of 29 ...

メーカー Omega Engineering カテゴリー Stud Sensor

Omega Engineering FLR1000のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- FLR1000の取扱説明書
- Omega Engineeringの製品カード
- パンフレット
- またはOmega Engineering FLR1000の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Omega Engineering FLR1000の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Omega Engineering FLR1000の取り付け説明書、サービスマニュアル、簡易説明書、またはOmega Engineering FLR1000のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Omega Engineering FLR1000の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Omega Engineering FLR1000デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがOmega Engineering FLR1000を使用するのを助ける技術的文書のことです。説明書は通常、全てのOmega Engineering FLR1000ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Omega Engineeringの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Omega Engineering FLR1000の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははOmega Engineering FLR1000の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Omega Engineering FLR1000に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Omega Engineering FLR1000デバイスの基本機能を使うにあたってのヒント。 Omega Engineering FLR1000のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Omega Engineering FLR1000に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるOmega Engineering FLR1000のメーカー/サービスへの連絡先に関する情報。

Omega Engineering FLR1000についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもOmega Engineering FLR1000の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがOmega Engineering FLR1000で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)