Manuale per l’uso Greenheck Fan ERH-20

20 pagine 0.25 mb
Scarica

Vai alla pagina of 20

Summary
  • Greenheck Fan ERH-20 - page 1

    **W ARNING** DISCONNECT AND SECURE TO THE "OFF" POSITION ALL ELECTRICAL POWER TO THE UNITS PRIOR TO INSPECTION OR SERVICING. F AILURE TO COMPL Y WITH THIS SAFETY PRECAUTION COULD RESUL T IN SERIOUS INJUR Y OR DEA TH. **IMPORT ANT** ALL F ACTORY PROVIDED LIFTING LUGS MUST BE USED WHEN LIFTING THE UNITS. F AILURE TO COMPL Y WITH THIS SAFETY ...

  • Greenheck Fan ERH-20 - page 2

    GENERAL Greenheck Energy Recovery units with Te mpering are thor oughly inspected and test run at the factory . However , damage may occur during handling and shipping. Consequently , it is important to inspect the unit for visible and concealed damage before beginning installation. Report any damage to the shipper immediately . In addition, assur ...

  • Greenheck Fan ERH-20 - page 3

    3 INST ALLA TION The system design and installation should follow accepted industry practice, such as described in the ASHRAE Handbook. Adequate space should be left around the unit for piping coils and drains, filter replacement, and maintenance. Suf ficient space should be provided on the side of the unit for r outine service and component remova ...

  • Greenheck Fan ERH-20 - page 4

    4 R o t a t i o n Length of Straight Duct GOOD R o t a t i o n POOR FIGURE 4 DUCT WORK CONNECTIONS Examples of good and poor fan-to-duct connections are shown below (See FIGURE 4). Airflow out of the fan should be directed straight or curve the same dir ection as the fan wheel rotates. Poor duct installation will r esult in low airflow and other sy ...

  • Greenheck Fan ERH-20 - page 5

    5 Main Disconnect On Off Exhaust Hood Control Center Intake Hood INST ALLA TION (continued) WEA THERHOODS Supply weatherhood will be factory mounted. The exhaust weatherhood is shipped separately as a kit with its own instructions. EXHAUST DAMPERS Backdraft dampers for exhaust discharge are mounted in the unit. Motorized dampers ar e shipped loose ...

  • Greenheck Fan ERH-20 - page 6

    Wheel Cassette 2 in. filters 2 in. filters Exhaust Air Intake Electrical Box Access Panel Access Panel Access Panel Access Panel Access Panel Cassette Slides Out 52 in. Clearance with IG Heater 0 in. Clearance without IG Heater Exhaust Hood Outdoor Air Hood IG Heater *48 in. **64 in. 36 in. 36 in. TOP VIEW SERVICE CLEARANCES / ACCESS P ANEL LOCA TI ...

  • Greenheck Fan ERH-20 - page 7

    1. Piping should be in accordance with accepted industry standards. Pipework should be supported independently of the coils. W ater connections are male NPT iron pipe. When installing couplings, do not apply undue stress to the connection extending through the unit. Use a backup pipe wrench to avoid br eaking the weld between coil connection and he ...

  • Greenheck Fan ERH-20 - page 8

    8 ELECTRIC HEA TER APPLICA TION/OPERA TION Factory installed electric heaters can be provided for pr eheat and/or post-heat (see FIGURE 11). An electric preheater warms the outdoor air prior to the energy r ecovery wheel to prevent fr osting on the wheel. An electric post-heater warms the air leaving the energy recovery wheel to a user specified di ...

  • Greenheck Fan ERH-20 - page 9

    FROST CONTROL APPLICA TION/OPERA TION DIRTY FIL TER SWITCH SETUP When outdoor air temperatures ar e extremely cold, moistur e condensation and frosting on the energy recovery wheel is possible. Frost contr ol is an optional feature that will pr event wheel frosting. T wo options are available: 1) Timed Exhaust frost contr ol and 2) Preheat fr ost c ...

  • Greenheck Fan ERH-20 - page 10

    The energy recovery wheel may be de-energized for the purpose of pr oviding economizer (free cooling) operation. This can be achieved with a signal from a T emperature or Enthalpy sensor mounted in the supply air inlet compartment (see FIGURE 13). This Primary sensor will de-energize the energy wheel when the outdoor air temperature (factory defaul ...

  • Greenheck Fan ERH-20 - page 11

    11 GENERAL Check all fasteners and set screws for tightness. This is especially important for bearings and fan wheels. Also, if dampers are not motorized, check that they open and close without binding. F AN WHEEL ROT A TION Hand rotate the blower to ensur e that the wheel is not rubbing against the scroll. If the blower is r otating in the wrong d ...

  • Greenheck Fan ERH-20 - page 12

    12 ENERGY RECOVERY WHEEL CAUTION: See **W ARNING** on page 1 and 11 For the ERH-20 and ERH-45, open the access door marked "Energy Wheel Cassette Access". UNPLUG the wheel drive motor and remove the metal spacer . Then pull the cassette out halfway as seen in FIGURE 17. Note: For the ERH-55 and ERH-90, the energy recovery wheel does not s ...

  • Greenheck Fan ERH-20 - page 13

    13 ROUTINE MAINTENANCE CAUTION: See **W ARNING** on Page 1 and 11 Once the unit has been put into operation, a periodic maintenance program should be set up to pr eserve the r eliability and performance. Items to be included in this pr ogram are: • BEL TS • MOTORS • WHEEL AND F ASTENERS • VIBRA TION • FIL TER MAINTENANCE • COIL MAINTENA ...

  • Greenheck Fan ERH-20 - page 14

    14 EXTERNAL FIL TER MAINTENANCE Aluminum mesh 2 in. filters are located in the supply weatherhood (if the weatherhood option was purchased). Filters should be checked and cleaned on a regular basis for best ef ficiency . The frequency of cleaning depends upon the cleanliness of the incoming air . To r emove these filters, remove bottom bolt in the ...

  • Greenheck Fan ERH-20 - page 15

    15 WA TER COIL MAINTENANCE CAUTION: See **W ARNING** on Page 1 and 11 FIL TERS Filters upstream of the coil should be checked r egularly . If the filters ar e dirty , they should be cleaned or r eplaced. It is important that the coils stay clean to maintain desir ed airflow . See page 14 for more information on filter maintenance. COIL MAINTENANCE ...

  • Greenheck Fan ERH-20 - page 16

    FIGURE 20 For the ERH-20 and ERH-45, open the access door marked "Energy Wheel Cassette Access" (FIGURE 20). UNPLUG the wheel drive motor and remove the metal spacer . Then pull the cassette out halfway (FIGURE 21). The energy recovery wheel cassettes for model ERH-55 and ERH-90 do not slide out due to their size and weight. Service to th ...

  • Greenheck Fan ERH-20 - page 17

    CLEANING ENERGY RECOVERY WHEEL SEGMENTS If the wheel appears excessively dirty , it should be cleaned to ensur e maximum operating efficiency . Only excessive buildup of foreign material needs to be r emoved. DISCOLORA TION AND ST AINING OF ENERGY RECOVERY WHEEL DOES NOT AFFECT ITS PERFORMANCE. Thoroughly spray wheel matrix with household cleaner s ...

  • Greenheck Fan ERH-20 - page 18

    PA R TS LIST 1 2 3 4 8 5 6 7 7 9 Model ERH (shown with indirect gas heater) 10 18 1. Supply blower - Forward curved fan - Adjustable motor mount for belt tensioning - Adjustable sheaves for speed control 2. Vibrations isolators (quantity 4 per blower) - Neoprene 3. Energy recovery wheel cassette 4. Removable energy recovery wheel segments 5. Option ...

  • Greenheck Fan ERH-20 - page 19

    * Always provide the unit model and serial number when requesting parts or service information. * Always check motor amps and compare to nameplate rating. 19 Control power (24 V ac) wiring run is too long (resistance should not exceed 0.75 ohms). Shorten wiring run to mechanical room or install a r elay which will turn unit on/off (C/F for relay in ...

  • Greenheck Fan ERH-20 - page 20

    IOM ERH FS Rev . 1 January 2002 W arranty Greenheck warrants this equipment to be fr ee from defects in material and workmanship for a period of one year from the purchase date. The energy r ecovery wheel is warranted to be free from defects in material and workmanship for a period of five years from the pur chase date. Any units or parts which pro ...

Fabbricante Greenheck Fan Categoria Electric Heater

I documenti che otteniamo dal fabbricante del dispositivoGreenheck Fan ERH-20 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Greenheck Fan
- manuali per l’uso ERH-20
- schede prodotto Greenheck Fan
- opuscoli
- o etichette energetiche Greenheck Fan ERH-20
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Greenheck Fan ERH-20.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Greenheck Fan ERH-20, manuali di manutenzione, brevi manuali o manuali utente Greenheck Fan ERH-20. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Greenheck Fan ERH-20.

Manuali per l’uso simili

Manuale completo del dispositivo Greenheck Fan ERH-20, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Greenheck Fan ERH-20 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Greenheck Fan ERH-20.

Il manuale per l’uso completo Greenheck Fan, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Greenheck Fan ERH-20 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Greenheck Fan ERH-20, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Greenheck Fan ERH-20 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Greenheck Fan ERH-20 - che ci dovrebbe aiutare nei primi passi durante l'uso Greenheck Fan ERH-20
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Greenheck Fan ERH-20
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Greenheck Fan ERH-20 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Greenheck Fan ERH-20?

Utilizza il modulo sottostante

Se non hai risolto il problema con Greenheck Fan ERH-20 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Greenheck Fan ERH-20 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)