  • Greenheck Fan ERH-20 - page 1

    **W ARNING** DISCONNECT AND SECURE TO THE "OFF" POSITION ALL ELECTRICAL POWER TO THE UNITS PRIOR TO INSPECTION OR SERVICING. F AILURE TO COMPL Y WITH THIS SAFETY PRECAUTION COULD RESUL T IN SERIOUS INJUR Y OR DEA TH. **IMPORT ANT** ALL F ACTORY PROVIDED LIFTING LUGS MUST BE USED WHEN LIFTING THE UNITS. F AILURE TO COMPL Y WITH THIS SAFETY ...

  • Greenheck Fan ERH-20 - page 2

    GENERAL Greenheck Energy Recovery units with Te mpering are thor oughly inspected and test run at the factory . However , damage may occur during handling and shipping. Consequently , it is important to inspect the unit for visible and concealed damage before beginning installation. Report any damage to the shipper immediately . In addition, assur ...

  • Greenheck Fan ERH-20 - page 3

    3 INST ALLA TION The system design and installation should follow accepted industry practice, such as described in the ASHRAE Handbook. Adequate space should be left around the unit for piping coils and drains, filter replacement, and maintenance. Suf ficient space should be provided on the side of the unit for r outine service and component remova ...

  • Greenheck Fan ERH-20 - page 4

    4 R o t a t i o n Length of Straight Duct GOOD R o t a t i o n POOR FIGURE 4 DUCT WORK CONNECTIONS Examples of good and poor fan-to-duct connections are shown below (See FIGURE 4). Airflow out of the fan should be directed straight or curve the same dir ection as the fan wheel rotates. Poor duct installation will r esult in low airflow and other sy ...

  • Greenheck Fan ERH-20 - page 5

    5 Main Disconnect On Off Exhaust Hood Control Center Intake Hood INST ALLA TION (continued) WEA THERHOODS Supply weatherhood will be factory mounted. The exhaust weatherhood is shipped separately as a kit with its own instructions. EXHAUST DAMPERS Backdraft dampers for exhaust discharge are mounted in the unit. Motorized dampers ar e shipped loose ...

  • Greenheck Fan ERH-20 - page 6

    Wheel Cassette 2 in. filters 2 in. filters Exhaust Air Intake Electrical Box Access Panel Access Panel Access Panel Access Panel Access Panel Cassette Slides Out 52 in. Clearance with IG Heater 0 in. Clearance without IG Heater Exhaust Hood Outdoor Air Hood IG Heater *48 in. **64 in. 36 in. 36 in. TOP VIEW SERVICE CLEARANCES / ACCESS P ANEL LOCA TI ...

  • Greenheck Fan ERH-20 - page 7

    1. Piping should be in accordance with accepted industry standards. Pipework should be supported independently of the coils. W ater connections are male NPT iron pipe. When installing couplings, do not apply undue stress to the connection extending through the unit. Use a backup pipe wrench to avoid br eaking the weld between coil connection and he ...

  • Greenheck Fan ERH-20 - page 8

    8 ELECTRIC HEA TER APPLICA TION/OPERA TION Factory installed electric heaters can be provided for pr eheat and/or post-heat (see FIGURE 11). An electric preheater warms the outdoor air prior to the energy r ecovery wheel to prevent fr osting on the wheel. An electric post-heater warms the air leaving the energy recovery wheel to a user specified di ...

  • Greenheck Fan ERH-20 - page 9

    FROST CONTROL APPLICA TION/OPERA TION DIRTY FIL TER SWITCH SETUP When outdoor air temperatures ar e extremely cold, moistur e condensation and frosting on the energy recovery wheel is possible. Frost contr ol is an optional feature that will pr event wheel frosting. T wo options are available: 1) Timed Exhaust frost contr ol and 2) Preheat fr ost c ...

  • Greenheck Fan ERH-20 - page 10

    The energy recovery wheel may be de-energized for the purpose of pr oviding economizer (free cooling) operation. This can be achieved with a signal from a T emperature or Enthalpy sensor mounted in the supply air inlet compartment (see FIGURE 13). This Primary sensor will de-energize the energy wheel when the outdoor air temperature (factory defaul ...

  • Greenheck Fan ERH-20 - page 11

    11 GENERAL Check all fasteners and set screws for tightness. This is especially important for bearings and fan wheels. Also, if dampers are not motorized, check that they open and close without binding. F AN WHEEL ROT A TION Hand rotate the blower to ensur e that the wheel is not rubbing against the scroll. If the blower is r otating in the wrong d ...

  • Greenheck Fan ERH-20 - page 12

    12 ENERGY RECOVERY WHEEL CAUTION: See **W ARNING** on page 1 and 11 For the ERH-20 and ERH-45, open the access door marked "Energy Wheel Cassette Access". UNPLUG the wheel drive motor and remove the metal spacer . Then pull the cassette out halfway as seen in FIGURE 17. Note: For the ERH-55 and ERH-90, the energy recovery wheel does not s ...

  • Greenheck Fan ERH-20 - page 13

    13 ROUTINE MAINTENANCE CAUTION: See **W ARNING** on Page 1 and 11 Once the unit has been put into operation, a periodic maintenance program should be set up to pr eserve the r eliability and performance. Items to be included in this pr ogram are: • BEL TS • MOTORS • WHEEL AND F ASTENERS • VIBRA TION • FIL TER MAINTENANCE • COIL MAINTENA ...

  • Greenheck Fan ERH-20 - page 14

    14 EXTERNAL FIL TER MAINTENANCE Aluminum mesh 2 in. filters are located in the supply weatherhood (if the weatherhood option was purchased). Filters should be checked and cleaned on a regular basis for best ef ficiency . The frequency of cleaning depends upon the cleanliness of the incoming air . To r emove these filters, remove bottom bolt in the ...

  • Greenheck Fan ERH-20 - page 15

    15 WA TER COIL MAINTENANCE CAUTION: See **W ARNING** on Page 1 and 11 FIL TERS Filters upstream of the coil should be checked r egularly . If the filters ar e dirty , they should be cleaned or r eplaced. It is important that the coils stay clean to maintain desir ed airflow . See page 14 for more information on filter maintenance. COIL MAINTENANCE ...

  • Greenheck Fan ERH-20 - page 16

    FIGURE 20 For the ERH-20 and ERH-45, open the access door marked "Energy Wheel Cassette Access" (FIGURE 20). UNPLUG the wheel drive motor and remove the metal spacer . Then pull the cassette out halfway (FIGURE 21). The energy recovery wheel cassettes for model ERH-55 and ERH-90 do not slide out due to their size and weight. Service to th ...

  • Greenheck Fan ERH-20 - page 17

    CLEANING ENERGY RECOVERY WHEEL SEGMENTS If the wheel appears excessively dirty , it should be cleaned to ensur e maximum operating efficiency . Only excessive buildup of foreign material needs to be r emoved. DISCOLORA TION AND ST AINING OF ENERGY RECOVERY WHEEL DOES NOT AFFECT ITS PERFORMANCE. Thoroughly spray wheel matrix with household cleaner s ...

  • Greenheck Fan ERH-20 - page 18

    PA R TS LIST 1 2 3 4 8 5 6 7 7 9 Model ERH (shown with indirect gas heater) 10 18 1. Supply blower - Forward curved fan - Adjustable motor mount for belt tensioning - Adjustable sheaves for speed control 2. Vibrations isolators (quantity 4 per blower) - Neoprene 3. Energy recovery wheel cassette 4. Removable energy recovery wheel segments 5. Option ...

  • Greenheck Fan ERH-20 - page 19

    * Always provide the unit model and serial number when requesting parts or service information. * Always check motor amps and compare to nameplate rating. 19 Control power (24 V ac) wiring run is too long (resistance should not exceed 0.75 ohms). Shorten wiring run to mechanical room or install a r elay which will turn unit on/off (C/F for relay in ...

  • Greenheck Fan ERH-20 - page 20

    IOM ERH FS Rev . 1 January 2002 W arranty Greenheck warrants this equipment to be fr ee from defects in material and workmanship for a period of one year from the purchase date. The energy r ecovery wheel is warranted to be free from defects in material and workmanship for a period of five years from the pur chase date. Any units or parts which pro ...

メーカー Greenheck Fan カテゴリー Electric Heater

Greenheck Fan ERH-20のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- ERH-20の取扱説明書
- Greenheck Fanの製品カード
- パンフレット
- またはGreenheck Fan ERH-20の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Greenheck Fan ERH-20の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Greenheck Fan ERH-20の取り付け説明書、サービスマニュアル、簡易説明書、またはGreenheck Fan ERH-20のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Greenheck Fan ERH-20の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Greenheck Fan ERH-20デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがGreenheck Fan ERH-20を使用するのを助ける技術的文書のことです。説明書は通常、全てのGreenheck Fan ERH-20ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Greenheck Fanの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Greenheck Fan ERH-20の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははGreenheck Fan ERH-20の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Greenheck Fan ERH-20に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Greenheck Fan ERH-20デバイスの基本機能を使うにあたってのヒント。 Greenheck Fan ERH-20のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Greenheck Fan ERH-20に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるGreenheck Fan ERH-20のメーカー/サービスへの連絡先に関する情報。

Greenheck Fan ERH-20についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもGreenheck Fan ERH-20の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがGreenheck Fan ERH-20で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)