Manuale per l’uso Cornelius R-404A

28 pagine 0.25 mb
Scarica

Vai alla pagina of 28

Summary
  • Cornelius R-404A - page 1

    Operator ’ s Manual FCB POST -MIX DISPENSER WITH V4 FEA TURES (R-404A REFRIGERANT) PRINTED IN U.S.A IMI CORNELIUS INC; 1996  Part No 312030002 May 8, 1996 Control Code A THIS DOCUMENT CONT AINS IMPORT ANT INFORMA TION This Manual must be read and understood before installing or operating this equipment ...

  • Cornelius R-404A - page 2

    i 312030002 T ABLE OF CONTENTS Page SAFETY INFORMA TION 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RECOGNIZE SAFETY INFORMA TION 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UNDERST AND SIGNAL WORDS 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Cornelius R-404A - page 3

    ii 312030002 T ABLE OF CONTENTS (cont ’ d) Page BAG – IN – BOX SYSTEM 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SYRUP FLA VOR CHANGE 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REPLENISHING CO2 SUPPL Y 12 . . . . . . . . . . . . . . . . . . . . . ...

  • Cornelius R-404A - page 4

    iii 312030002 T ABLE OF CONTENTS (cont ’ d) Page CYLINDER FREEZE-UP . 20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . W ARRANTY 21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LIST OF FIGURES FIGURE 1. FCB POST -MIX DISPENSERS W ...

  • Cornelius R-404A - page 5

    iv 312030002 THIS P AGE LEFT BLANK INTENTIONALL Y ...

  • Cornelius R-404A - page 6

    1 312030002 SAFETY INFORMA TION Recognize Safety Information This is the safety-alert symbol. When you see this symbol on our machine or in this manual, be alert to the potentially of personal injury . Follow recommended precautions and safe operating practices. DANGER Understand Signal Words A signal word - DANGER, W ARNING, OR CAUTION is used wit ...

  • Cornelius R-404A - page 7

    312030002 2 THIS P AGE LEFT BLANK INTENTIONALL Y ...

  • Cornelius R-404A - page 8

    312030002 3 OPERA T OR ’ S INSTRUCTIONS This section describes operating controls and indicators, dispensed product conditions, operating characteris- tics, Unit operation, replenishing syrup supply , product flavor change, checking CO 2 supply , operators daily cleaning of Unit, and sanitizing requirements. TWO-FLA VOR DISPENSER FOUR-FLA VOR DIS ...

  • Cornelius R-404A - page 9

    312030002 4 MS (Forward)> <(Backward) Display ON MOTOR Side 1 Side 2 BLEND ON/OFF SYRUP PRIME OFF ERROR RESET Manual Defrost Menu/Select Cancel Defrost ER FIGURE 2. CONTROL P ANEL SWITCH IDENTIFICA TION ‘‘ SYRUP PRIME ’’ Switches. The ‘‘ SYRUP PRIME ’’ switches, located on the control panel, are touch-type switches and require ...

  • Cornelius R-404A - page 10

    312030002 5 T OP P ANEL CONTROL P ANEL (2) (SEE FIGURE 2) F ACEPLA TE RELIEF V AL VE (4) CUP REST DRIP TRA Y SIDE P ANEL (2) F ACEPLA TE (4) BACK P ANEL VENTILA TION LOUVERS NOTE: T wo-flavor Unit - The No. 1 freeze cylinder is the left-hand cylinder facing the front of the Unit. No. 2 freeze cylinder is to the right of No. 1 freeze cylinder . Four ...

  • Cornelius R-404A - page 11

    312030002 6 CONTROL P ANEL DISPLA Y MESSAGES ‘‘ FILL 1 ’’ and ‘‘ FILL 2 ’’ Fault Messages. ‘‘ FILL 1 ’’ and ‘‘ FILL 2 ’’ fault messages will appear on the message display only after the “ SYRUP PRIME ” switches have been pressed and the syrup systems sold-out floats have been filled with product. ‘‘ FILL 1 ? ...

  • Cornelius R-404A - page 12

    312030002 7 DEFROST SYSTEMS NOTE: The automatic defrost, “ SLEEP ” (SLEEP TIME), and “ W AKE UP ” (W AKE UP TIME) should be programmed into the Unit electronics by a qualified Service Person. UNITS EQUIPPED WITH HOT -GAS DEFROST SYSTEMS The Unit is equipped with both manual and automatic hot-gas defrost systems. The automatic defrost system ...

  • Cornelius R-404A - page 13

    312030002 8 Automatic Electric Defrost System. The automatic electric defrost system may be programmed into the Unit to occur up to nine different times a day with a minimum of two hours between defrost settings. At start of each automatic electric defrost cycle, the re- frigeration compressor will operate for a short time. No.1 freeze cylinder onl ...

  • Cornelius R-404A - page 14

    312030002 9 DISPENSED PRODUCT CONDITIONS ‘‘ OVERRUN ’’ , AS APPLIED TO FROZEN CARBONA TED BEVERAGES Overrun Defined. Overrun is product expansion that takes place in the frozen carbonated drink. It is caused primarily by CO 2 gas breakout and secondary by freezing. Low Dispensing V olume Affects Overrun. When the Unit sits idle for a period ...

  • Cornelius R-404A - page 15

    312030002 10 Freezing Affects Overrun. Freezing causes approximately a 10 percent expansion in a dispensed frozen carbonated drink. The degree of freezing is limited because the finished drink is intended to be sipped through a straw . This is not possible if the product is too ‘‘ solid ’’ . OPERA TING CHARACTERISTICS The product viscosity ...

  • Cornelius R-404A - page 16

    312030002 11 SECONDAR Y CO 2 REGULA TORS The secondary CO 2 regulators, located inside the Unit, control CO 2 pressure to the Unit carbonator(s) and the product blender tanks. If adjustment of these CO 2 regulators should become necessary , call a qualified Service Person to make the adjustments. ADJUSTING BRIX (W A TER-T O-SYRUP “ RA TIO ” ) O ...

  • Cornelius R-404A - page 17

    312030002 12 8. If freeze cylinder is not full of product, repeatedly pull and release the faceplate relief valve to slowly bleed CO 2 from the freeze cylinder and allow product to fill the cylinder . Do not relieve freeze cylinder pressure too fast or the product will foam excessively in the cylinder and lose carbonation. BAG – IN – BOX SYSTEM ...

  • Cornelius R-404A - page 18

    312030002 13 3. Unfasten safety chain and remove empty CO 2 cylinder . 4. Position full CO 2 cylinder and secure with safety chain. W ARNING: T o avoid personal injury and/or property damage, always secure CO 2 cylinder in an upright position with safety chain to prevent it from falling over . Should the shutoff valve become accidentally broken off ...

  • Cornelius R-404A - page 19

    312030002 14 10. Syrup T ank Syrup System. Disconnect syrup tank containing syrup from No. 1 syrup system. Bag-in-Box Syrup System. A. Disconnect No. 1 syrup pump syrup inlet line from bag-in-box containing syrup. B. Cut connector from empty bag-in-box container , then connect connector to No. 1 syrup pump syrup inlet line. NOTE: Sanitizing solutio ...

  • Cornelius R-404A - page 20

    312030002 15 Bag-in-Box Syrup System. A. Remove end of No. 1 syrup pump syrup inlet line from pail of sanitizing solution. B. Remove empty bag-in-box connector from No. 1 syrup pump syrup inlet line. C. Connect No. 1 syrup pump syrup inlet line to bag-in-box containing syrup. 22. Press SIDE 1 “ SYRUP PRIME ” switch to fill No. 1 syrup system sy ...

  • Cornelius R-404A - page 21

    312030002 16 32. After carbonator water pump cycles off, intermittently pull and release the No. 1 freeze cylinder faceplate relief valve. This bleeds CO 2 from the freeze cylinder and allows product to enter and fill the cylinder . 33. Open No. 2 product blender tank product shutoff valve. CLEANING CONDENSER COIL UNIT WITH AIR-COOLED REFRIGERA TIO ...

  • Cornelius R-404A - page 22

    17 312030002 W ARNING: If repairs are to be made to a product system, remove quick disconnects from the applicable product tank, then relieve the system pressure before proceeding. If repairs are to be made to the CO 2 system, stop dispensing, shut off the CO 2 supply , then relieve the system pressure before proceeding. If repairs are to be made t ...

  • Cornelius R-404A - page 23

    18 312030002 T rouble Remedy Probable Cause ‘‘ CO 2 OUT ’’ F AUL T MESSAGE GOES ON DURING OPERA TION. A. CO 2 supply turned off or exhausted. A. Open CO 2 cylinder shutof f valve or replenish CO 2 supply as instructed. B. Primary CO 2 regulator set too low . B. Call qualified Service Person to adjust primary CO 2 regulator . C. Inoperable C ...

  • Cornelius R-404A - page 24

    19 312030002 T rouble Remedy Probable Cause CARBONA TOR W A TER PUMP WILL NOT SHUT OFF . A. Binding, damaged, or dirty carbonated water tank balance mechanism. A. Call qualified Service Person.. ERRA TIC CARBONA TOR W A TER PUMP CYCLING. A. Insufficient water supply pressure. ‘‘ H 2 O OUT ’’ fault message goes on and off intermittently and ...

  • Cornelius R-404A - page 25

    20 312030002 T rouble Remedy Probable Cause FROZEN PRODUCT CONSISTENCY V ARIES EXCESSIVEL Y (CONT ’ D). B. Cylinder freeze-up causing ice formation in center of cylinder and liquid product channels around ice formation. B. Refer to CYLINDER FREEZE-UP . NOTE: DEFROST AFFECTED FREEZE CYLINDER AS INSTRUCTED. CYLINDER FREEZE-UP . A. Dispensed product ...

  • Cornelius R-404A - page 26

    312030002 21 W ARRANTY IMI Cornelius Inc. warrants that all equipment and parts are free from defects in material and workmanship un- der normal use and service. For a copy of the warranty applicable to your Cornelius, Remcor or W ilshire prod- uct, in your country , please write, fax or telephone the IMI Cornelius office nearest you. Please provid ...

  • Cornelius R-404A - page 27

    ...

  • Cornelius R-404A - page 28

    IMI CORNELIUS INC. CORPORA TE HEADQUARTERS: One Cornelius Place Anoka, Minnesota 55303-6234 (612) 421-6120 (800) 238-3600 ...

Fabbricante Cornelius Categoria Beverage Dispenser

I documenti che otteniamo dal fabbricante del dispositivoCornelius R-404A possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Cornelius
- manuali per l’uso R-404A
- schede prodotto Cornelius
- opuscoli
- o etichette energetiche Cornelius R-404A
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Cornelius R-404A.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Cornelius R-404A, manuali di manutenzione, brevi manuali o manuali utente Cornelius R-404A. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Cornelius R-404A.

Manuali per l’uso simili

Manuale completo del dispositivo Cornelius R-404A, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Cornelius R-404A dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Cornelius R-404A.

Il manuale per l’uso completo Cornelius, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Cornelius R-404A - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Cornelius R-404A, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Cornelius R-404A che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Cornelius R-404A - che ci dovrebbe aiutare nei primi passi durante l'uso Cornelius R-404A
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Cornelius R-404A
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Cornelius R-404A in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Cornelius R-404A?

Utilizza il modulo sottostante

Se non hai risolto il problema con Cornelius R-404A con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Cornelius R-404A è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)