    Operator ’ s Manual FCB POST -MIX DISPENSER WITH V4 FEA TURES (R-404A REFRIGERANT) PRINTED IN U.S.A IMI CORNELIUS INC; 1996  Part No 312030002 May 8, 1996 Control Code A THIS DOCUMENT CONT AINS IMPORT ANT INFORMA TION This Manual must be read and understood before installing or operating this equipment ...

  • Cornelius R-404A - page 2

    i 312030002 T ABLE OF CONTENTS Page SAFETY INFORMA TION 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RECOGNIZE SAFETY INFORMA TION 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UNDERST AND SIGNAL WORDS 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Cornelius R-404A - page 3

    ii 312030002 T ABLE OF CONTENTS (cont ’ d) Page BAG – IN – BOX SYSTEM 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SYRUP FLA VOR CHANGE 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REPLENISHING CO2 SUPPL Y 12 . . . . . . . . . . . . . . . . . . . . . ...

  • Cornelius R-404A - page 4

    iii 312030002 T ABLE OF CONTENTS (cont ’ d) Page CYLINDER FREEZE-UP . 20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . W ARRANTY 21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LIST OF FIGURES FIGURE 1. FCB POST -MIX DISPENSERS W ...

  • Cornelius R-404A - page 5

    iv 312030002 THIS P AGE LEFT BLANK INTENTIONALL Y ...

  • Cornelius R-404A - page 6

    1 312030002 SAFETY INFORMA TION Recognize Safety Information This is the safety-alert symbol. When you see this symbol on our machine or in this manual, be alert to the potentially of personal injury . Follow recommended precautions and safe operating practices. DANGER Understand Signal Words A signal word - DANGER, W ARNING, OR CAUTION is used wit ...

  • Cornelius R-404A - page 7

    312030002 2 THIS P AGE LEFT BLANK INTENTIONALL Y ...

  • Cornelius R-404A - page 8

    312030002 3 OPERA T OR ’ S INSTRUCTIONS This section describes operating controls and indicators, dispensed product conditions, operating characteris- tics, Unit operation, replenishing syrup supply , product flavor change, checking CO 2 supply , operators daily cleaning of Unit, and sanitizing requirements. TWO-FLA VOR DISPENSER FOUR-FLA VOR DIS ...

  • Cornelius R-404A - page 9

    312030002 4 MS (Forward)> <(Backward) Display ON MOTOR Side 1 Side 2 BLEND ON/OFF SYRUP PRIME OFF ERROR RESET Manual Defrost Menu/Select Cancel Defrost ER FIGURE 2. CONTROL P ANEL SWITCH IDENTIFICA TION ‘‘ SYRUP PRIME ’’ Switches. The ‘‘ SYRUP PRIME ’’ switches, located on the control panel, are touch-type switches and require ...

  • Cornelius R-404A - page 10

    312030002 5 T OP P ANEL CONTROL P ANEL (2) (SEE FIGURE 2) F ACEPLA TE RELIEF V AL VE (4) CUP REST DRIP TRA Y SIDE P ANEL (2) F ACEPLA TE (4) BACK P ANEL VENTILA TION LOUVERS NOTE: T wo-flavor Unit - The No. 1 freeze cylinder is the left-hand cylinder facing the front of the Unit. No. 2 freeze cylinder is to the right of No. 1 freeze cylinder . Four ...

  • Cornelius R-404A - page 11

    312030002 6 CONTROL P ANEL DISPLA Y MESSAGES ‘‘ FILL 1 ’’ and ‘‘ FILL 2 ’’ Fault Messages. ‘‘ FILL 1 ’’ and ‘‘ FILL 2 ’’ fault messages will appear on the message display only after the “ SYRUP PRIME ” switches have been pressed and the syrup systems sold-out floats have been filled with product. ‘‘ FILL 1 ? ...

  • Cornelius R-404A - page 12

    312030002 7 DEFROST SYSTEMS NOTE: The automatic defrost, “ SLEEP ” (SLEEP TIME), and “ W AKE UP ” (W AKE UP TIME) should be programmed into the Unit electronics by a qualified Service Person. UNITS EQUIPPED WITH HOT -GAS DEFROST SYSTEMS The Unit is equipped with both manual and automatic hot-gas defrost systems. The automatic defrost system ...

  • Cornelius R-404A - page 13

    312030002 8 Automatic Electric Defrost System. The automatic electric defrost system may be programmed into the Unit to occur up to nine different times a day with a minimum of two hours between defrost settings. At start of each automatic electric defrost cycle, the re- frigeration compressor will operate for a short time. No.1 freeze cylinder onl ...

  • Cornelius R-404A - page 14

    312030002 9 DISPENSED PRODUCT CONDITIONS ‘‘ OVERRUN ’’ , AS APPLIED TO FROZEN CARBONA TED BEVERAGES Overrun Defined. Overrun is product expansion that takes place in the frozen carbonated drink. It is caused primarily by CO 2 gas breakout and secondary by freezing. Low Dispensing V olume Affects Overrun. When the Unit sits idle for a period ...

  • Cornelius R-404A - page 15

    312030002 10 Freezing Affects Overrun. Freezing causes approximately a 10 percent expansion in a dispensed frozen carbonated drink. The degree of freezing is limited because the finished drink is intended to be sipped through a straw . This is not possible if the product is too ‘‘ solid ’’ . OPERA TING CHARACTERISTICS The product viscosity ...

  • Cornelius R-404A - page 16

    312030002 11 SECONDAR Y CO 2 REGULA TORS The secondary CO 2 regulators, located inside the Unit, control CO 2 pressure to the Unit carbonator(s) and the product blender tanks. If adjustment of these CO 2 regulators should become necessary , call a qualified Service Person to make the adjustments. ADJUSTING BRIX (W A TER-T O-SYRUP “ RA TIO ” ) O ...

  • Cornelius R-404A - page 17

    312030002 12 8. If freeze cylinder is not full of product, repeatedly pull and release the faceplate relief valve to slowly bleed CO 2 from the freeze cylinder and allow product to fill the cylinder . Do not relieve freeze cylinder pressure too fast or the product will foam excessively in the cylinder and lose carbonation. BAG – IN – BOX SYSTEM ...

  • Cornelius R-404A - page 18

    312030002 13 3. Unfasten safety chain and remove empty CO 2 cylinder . 4. Position full CO 2 cylinder and secure with safety chain. W ARNING: T o avoid personal injury and/or property damage, always secure CO 2 cylinder in an upright position with safety chain to prevent it from falling over . Should the shutoff valve become accidentally broken off ...

  • Cornelius R-404A - page 19

    312030002 14 10. Syrup T ank Syrup System. Disconnect syrup tank containing syrup from No. 1 syrup system. Bag-in-Box Syrup System. A. Disconnect No. 1 syrup pump syrup inlet line from bag-in-box containing syrup. B. Cut connector from empty bag-in-box container , then connect connector to No. 1 syrup pump syrup inlet line. NOTE: Sanitizing solutio ...

  • Cornelius R-404A - page 20

    312030002 15 Bag-in-Box Syrup System. A. Remove end of No. 1 syrup pump syrup inlet line from pail of sanitizing solution. B. Remove empty bag-in-box connector from No. 1 syrup pump syrup inlet line. C. Connect No. 1 syrup pump syrup inlet line to bag-in-box containing syrup. 22. Press SIDE 1 “ SYRUP PRIME ” switch to fill No. 1 syrup system sy ...

  • Cornelius R-404A - page 21

    312030002 16 32. After carbonator water pump cycles off, intermittently pull and release the No. 1 freeze cylinder faceplate relief valve. This bleeds CO 2 from the freeze cylinder and allows product to enter and fill the cylinder . 33. Open No. 2 product blender tank product shutoff valve. CLEANING CONDENSER COIL UNIT WITH AIR-COOLED REFRIGERA TIO ...

  • Cornelius R-404A - page 22

    17 312030002 W ARNING: If repairs are to be made to a product system, remove quick disconnects from the applicable product tank, then relieve the system pressure before proceeding. If repairs are to be made to the CO 2 system, stop dispensing, shut off the CO 2 supply , then relieve the system pressure before proceeding. If repairs are to be made t ...

  • Cornelius R-404A - page 23

    18 312030002 T rouble Remedy Probable Cause ‘‘ CO 2 OUT ’’ F AUL T MESSAGE GOES ON DURING OPERA TION. A. CO 2 supply turned off or exhausted. A. Open CO 2 cylinder shutof f valve or replenish CO 2 supply as instructed. B. Primary CO 2 regulator set too low . B. Call qualified Service Person to adjust primary CO 2 regulator . C. Inoperable C ...

  • Cornelius R-404A - page 24

    19 312030002 T rouble Remedy Probable Cause CARBONA TOR W A TER PUMP WILL NOT SHUT OFF . A. Binding, damaged, or dirty carbonated water tank balance mechanism. A. Call qualified Service Person.. ERRA TIC CARBONA TOR W A TER PUMP CYCLING. A. Insufficient water supply pressure. ‘‘ H 2 O OUT ’’ fault message goes on and off intermittently and ...

  • Cornelius R-404A - page 25

    20 312030002 T rouble Remedy Probable Cause FROZEN PRODUCT CONSISTENCY V ARIES EXCESSIVEL Y (CONT ’ D). B. Cylinder freeze-up causing ice formation in center of cylinder and liquid product channels around ice formation. B. Refer to CYLINDER FREEZE-UP . NOTE: DEFROST AFFECTED FREEZE CYLINDER AS INSTRUCTED. CYLINDER FREEZE-UP . A. Dispensed product ...

  • Cornelius R-404A - page 26

    312030002 21 W ARRANTY IMI Cornelius Inc. warrants that all equipment and parts are free from defects in material and workmanship un- der normal use and service. For a copy of the warranty applicable to your Cornelius, Remcor or W ilshire prod- uct, in your country , please write, fax or telephone the IMI Cornelius office nearest you. Please provid ...

  • Cornelius R-404A - page 27

    ...

  • Cornelius R-404A - page 28

    IMI CORNELIUS INC. CORPORA TE HEADQUARTERS: One Cornelius Place Anoka, Minnesota 55303-6234 (612) 421-6120 (800) 238-3600 ...

メーカー Cornelius カテゴリー Beverage Dispenser

Cornelius R-404Aのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- R-404Aの取扱説明書
- Corneliusの製品カード
- パンフレット
- またはCornelius R-404Aの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Cornelius R-404Aの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Cornelius R-404Aの取り付け説明書、サービスマニュアル、簡易説明書、またはCornelius R-404Aのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Cornelius R-404Aの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Cornelius R-404Aデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがCornelius R-404Aを使用するのを助ける技術的文書のことです。説明書は通常、全てのCornelius R-404Aユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Corneliusの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Cornelius R-404Aの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははCornelius R-404Aの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Cornelius R-404Aに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Cornelius R-404Aデバイスの基本機能を使うにあたってのヒント。 Cornelius R-404Aのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Cornelius R-404Aに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるCornelius R-404Aのメーカー/サービスへの連絡先に関する情報。

Cornelius R-404Aについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもCornelius R-404Aの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがCornelius R-404Aで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)